solar inverter with built in solar charger contoller
Product Description
Model |
APC 1000W |
APC 2000W |
APC 3000W |
APC 4000W |
APC 5000W |
APC 6000W |
Inverter Output |
Continuous Output Power |
1000W |
2000W |
3000W |
4000W |
5000W |
6000W |
Surge Rating(20s) |
3000W |
6000W |
9000W |
12000W |
15000W |
18000W |
Capable of Starting Electric Motor |
1HP |
2HP |
3HP |
4HP |
5HP |
6HP |
Output Waveform |
Pure Sine wave/Same as input(Bypass mode) |
Nominal Efficiency |
>88%(Peak) |
Line Mode Efficiency |
>95% |
Power Factor |
0.9-1.0 |
Nominal Output Voltage rms |
110V/120/220V/230/240VAC |
Output Voltage Regulation |
±10% rms |
Output Frequency |
50Hz ± 0.3Hz/60Hz ± 0.3Hz |
Short Circuit Protection |
Yes, Current Limit Function (fault after 1s ) |
Typical transfer Time |
10ms(Max) |
THD |
less than 3% |
DC Input |
Nominal Input Voltage |
12V |
24V |
48V |
Minimum Start Voltage |
10V |
20V |
40V |
Low Battery Alarm |
10.5V |
21V |
42V |
Low Battery Trip |
10V |
20V |
40V |
High Voltage Alarm & Fault |
16V |
32V |
64V |
High DC Input Recovery |
15.5V |
Low Battery voltage recover |
13V |
26V |
52V |
Idle Consumption-Search Mode |
< 25 W when Power Saver On |
Charge |
Input Voltage Range |
95-127VAC |
194-243VAC |
164-243VAC(W) |
Output Voltage |
Depends on battery type |
Charger Breaker Rating |
10A |
10A |
20A |
20A |
30A |
30A |
Max Charge Rate |
35A / 70A |
Battery Initial Voltage for Start Up |
2V-15.7V for 12V( *2 for 24V, *4 for 48V) |
Over Charge Protection Shutdown |
15.7V for 12V (*2 for 24V, *4 for 48V) |
Charger curve(4 stage constant current)Battery types 4 step digital controlled
progressive charge
|
Battery type |
Fast V Float V ( *2 for 24v, *4 for 48v) |
Gel U.S.A |
14 |
13.7 |
A.G.M 1 |
14.1 |
13.4 |
A.G.M 2 |
14.6 |
13.7 |
Sealed Lead Acid |
14.4 |
13.6 |
Gel Euro |
14.4 |
13.8 |
Open Lead Acid |
14.8 |
13.3 |
Calcium |
15.1 |
13.6 |
De-sulphation |
15.5 for 4hrs |
Remote Control |
Yes. Optional |
Bypass & Protection |
Input Voltage Waveform |
Sine wave (Grid or Generator) |
Nominal Voltage |
110VAC/120VAC |
230VAC |
Low Voltage Trip |
80V/90V±4% |
184V/154V±4% |
Low Voltage re engage |
90V/100V±4% |
194V/164V±4% |
High Voltage Trip |
140V±4% |
253V±4% |
High Voltage re engage |
135V±4% |
243V±4% |
Max Input AC Voltage |
150VAC |
270VAC |
Nominal Input Frequency |
50Hz or 60Hz (Auto detect) |
Low Freq Trip |
47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz |
Low Freq re engage |
48±0.3Hz for 50Hz, 58±0.3Hz for 60Hz |
High Freq Trip |
55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz |
High Freq re engage |
54±0.3Hz for 50Hz, 64±0.3Hz for 60Hz |
Overload protection |
Circuit breaker |
Output Short circuit protection |
Circuit breaker |
Bypass breaker rating |
10A |
20A |
30A |
30A |
40A |
40A |
Transfer switch rating |
30amp for UL & TUV |
40amp for UL |
Max bypass current |
30amp |
40amp |
Bypass over load current |
35amp: Alarm |
45amp: Alarm |
Mechanical Specifications |
Mounting |
Wall mount |
Inverter Dimensions(L*W*H) |
382*218*179mm |
442*218*179mm |
598*218*179mm |
Inverter Weight |
16KG |
20KG |
24KG |
35KG |
45KG |
45KG |
Shipping Dimensions(L*W*H) |
520*315*300mm |
580*315*300mm |
740*315*300mm |
Shipping Weight |
18KG |
22KG |
26KG |
37KG |
47KG |
47KG |
Display |
Status LEDs / Status LEDs+LCD |
Standard Warranty |
1 Year |
Payment Terms: | TT/LC/Western Union |
| |
Product Image
Send Inquiry to this Member
Related Products of this Company
This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please
click here.
China Suppliers Quick Searching:
,