Model: | APC |
---|---|
Brand: | EYEN |
Origin: | Made In China |
Category: | Computers & AV Digital / Computer Accessories / UPS Power Supply |
Label: | DC to AC inverter , inverter , power inverter |
Price: |
-
|
Min. Order: | 20 pc |
Last Online:23 Jun, 2017 |
Model | APC 1000W | APC 2000W | APC 3000W | APC 4000W | APC 5000W | APC 6000W | |
Inverter Output | Continuous Output Power | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W |
Surge Rating(20s) | 3000W | 6000W | 9000W | 12000W | 15000W | 18000W | |
Capable of Starting Electric Motor | 1HP | 2HP | 3HP | 4HP | 5HP | 6HP | |
Output Waveform | Pure Sine wave/Same as input(Bypass mode) | ||||||
Nominal Efficiency | >88%(Peak) | ||||||
Line Mode Efficiency | >95% | ||||||
Power Factor | 0.9-1.0 | ||||||
Nominal Output Voltage rms | 110V/120/220V/230/240VAC | ||||||
Output Voltage Regulation | ±10% rms | ||||||
Output Frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | ||||||
Short Circuit Protection | Yes, Current Limit Function (fault after 1s ) | ||||||
Typical transfer Time | 10ms(Max) | ||||||
THD | less than 3% | ||||||
DC Input | Nominal Input Voltage | 12V | 24V | 48V | |||
Minimum Start Voltage | 10V | 20V | 40V | ||||
Low Battery Alarm | 10.5V | 21V | 42V | ||||
Low Battery Trip | 10V | 20V | 40V | ||||
High Voltage Alarm & Fault | 16V | 32V | 64V | ||||
High DC Input Recovery | 15.5V | ||||||
Low Battery voltage recover | 13V | 26V | 52V | ||||
Idle Consumption-Search Mode | < 25 W when Power Saver On | ||||||
Charge | Input Voltage Range | 95-127VAC | 194-243VAC | 164-243VAC(W) | |||
Output Voltage | Depends on battery type | ||||||
Charger Breaker Rating | 10A | 10A | 20A | 20A | 30A | 30A | |
Max Charge Rate | 35A / 70A | ||||||
Battery Initial Voltage for Start Up | 2V-15.7V for 12V( *2 for 24V, *4 for 48V) | ||||||
Over Charge Protection Shutdown | 15.7V for 12V (*2 for 24V, *4 for 48V) | ||||||
Charger curve(4 stage constant current)Battery types 4 step digital controlled
progressive charge |
|||||||
Battery type | Fast V Float V ( *2 for 24v, *4 for 48v) | ||||||
Gel U.S.A | 14 | 13.7 | |||||
A.G.M 1 | 14.1 | 13.4 | |||||
A.G.M 2 | 14.6 | 13.7 | |||||
Sealed Lead Acid | 14.4 | 13.6 | |||||
Gel Euro | 14.4 | 13.8 | |||||
Open Lead Acid | 14.8 | 13.3 | |||||
Calcium | 15.1 | 13.6 | |||||
De-sulphation | 15.5 for 4hrs | ||||||
Remote Control | Yes. Optional | ||||||
Bypass & Protection | Input Voltage Waveform | Sine wave (Grid or Generator) | |||||
Nominal Voltage | 110VAC/120VAC | 230VAC | |||||
Low Voltage Trip | 80V/90V±4% | 184V/154V±4% | |||||
Low Voltage re engage | 90V/100V±4% | 194V/164V±4% | |||||
High Voltage Trip | 140V±4% | 253V±4% | |||||
High Voltage re engage | 135V±4% | 243V±4% | |||||
Max Input AC Voltage | 150VAC | 270VAC | |||||
Nominal Input Frequency | 50Hz or 60Hz (Auto detect) | ||||||
Low Freq Trip | 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | ||||||
Low Freq re engage | 48±0.3Hz for 50Hz, 58±0.3Hz for 60Hz | ||||||
High Freq Trip | 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | ||||||
High Freq re engage | 54±0.3Hz for 50Hz, 64±0.3Hz for 60Hz | ||||||
Overload protection | Circuit breaker | ||||||
Output Short circuit protection | Circuit breaker | ||||||
Bypass breaker rating | 10A | 20A | 30A | 30A | 40A | 40A | |
Transfer switch rating | 30amp for UL & TUV | 40amp for UL | |||||
Max bypass current | 30amp | 40amp | |||||
Bypass over load current | 35amp: Alarm | 45amp: Alarm | |||||
Mechanical Specifications | |||||||
Mounting | Wall mount | ||||||
Inverter Dimensions(L*W*H) | 382*218*179mm | 442*218*179mm | 598*218*179mm | ||||
Inverter Weight | 16KG | 20KG | 24KG | 35KG | 45KG | 45KG | |
Shipping Dimensions(L*W*H) | 520*315*300mm | 580*315*300mm | 740*315*300mm | ||||
Shipping Weight | 18KG | 22KG | 26KG | 37KG | 47KG | 47KG | |
Display | Status LEDs / Status LEDs+LCD | ||||||
Standard Warranty | 1 Year |
Payment Terms: | TT/LC/Western Union/Cash |
---|---|