OFFGRID SOLAR INVERTER-1000W
Product Description
Electrical Specvifications |
Model |
APV 1000W |
APV 1500W |
APV 2000W |
APV 3000W |
APV 4000W |
APV 5000W |
APV 6000W |
Output (Inverter mode) |
Continuous Output Power |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
6000W |
Surge Rating |
3000W |
4500W |
6000W |
9000W |
12000W |
15000W |
18000W |
Output Waveform |
Pure Sine wave/Same as input(Bypass mode) |
Nominal Efficiency |
>88%(Peak) |
Line Mode Efficiency |
>95% |
Power Factor |
0.9-1.0 |
Nominal Output Voltage rms |
100-110-120Vac / 220-230-240Vac |
Output Voltage Regulation |
±10% RMS |
Output Frequency |
50Hz ± 0.3Hz/60Hz ± 0.3Hz |
Short Circuit Protection |
Yes( 1sec after fault ) |
Typical Line Stansfer Time |
10ms(MAX) |
THD |
<10% |
DC Input |
Nominal Input Voltage |
12.0Vdc |
( *2 for 24Vdc, *4 for 48Vdc) |
Minimum Start Voltage |
10.0Vdc |
Low Battery Alarm |
10.5Vdc / 11.0Vdc |
Low Battery Trip |
10.0Vdc / 10.5Vdc |
High Voltage Alarm |
16.0Vdc |
Low Battery voltage recover |
15.5Vdc |
Idle Consumption-Search Mode |
< 25 W when Power Saver On |
AC Charger |
Input Voltage Range |
Wide: 90~135VAC / 164~243VAC;
Narraw: 100~135VAC / 194~243VAC; |
Output Voltage |
Depends on battery type |
Max Charge Rate |
35A / 70-90A Max (Charger Current Control) |
Battery Initial Voltage for Start Up |
Circuit breaker |
Over Charge Protection Shutdown |
15.7V for 12V( *2 for 24Vdc, *4 for 48Vdc) |
Charger curve(4 stage constant current)
4 step digital controlled progressive charge |
Battery types ( *2 for 24Vdc, *4 for 48Vdc) |
Battery type |
Fast V Float V( *2 for 24Vdc, *4 for 48Vdc) |
Gel U.S.A |
14.0 |
13.7 |
A.G.M 1 |
14.1 |
13.4 |
A.G.M 2 |
14.6 |
13.7 |
Sealed Lead Acid |
14.4 |
13.6 |
Gel Euro |
14.4 |
13.8 |
Open Lead Acid |
14.8 |
13.3 |
Calcium |
15.1 |
13.6 |
De-sulphation |
15.5 for 4hrs |
Remote Control |
Yes. Optional |
Bypass & Protection |
Input Voltage Waveform |
Sine wave (Grid or Generator) |
Nominal Voltage |
120VAC / 230VAC |
Low Voltage Trip |
90V±4%/184V/154V±4% |
Low Voltage re engage |
100V±4%/194V/164V±4% |
High Voltage Trip |
140V±4%/ 253V±4% |
High Voltage re engage |
135V±4%/243V±4% |
Max Input AC Voltage |
150VAC/270VAC |
Nominal Input Frequency |
50Hz or 60Hz (Auto detect) |
Low freq trip |
47Hz± 0.3Hz for 50Hz, 57Hz± 0.3Hz for 60Hz |
Low freq re engage |
48Hz± 0.3Hz for 50Hz, 58Hz± 0.3Hz for 60Hz |
High freq trip |
55Hz± 0.3Hz for 50Hz, 65Hz± 0.3Hz for 60Hz |
High freq re engage |
54Hz± 0.3Hz for 50Hz, 64Hz± 0.3Hz for 60Hz |
Overload protection |
Circuit breaker |
Short circuit protection |
Circuit breaker |
Transfer switch rating |
30amp |
40amp |
Max bypass current |
30amp |
40amp |
Bypass over load current |
35amp: Alarm |
45amp: Alarm |
Solar Charger |
Rated Voltage |
12V/24V/48V |
Rated Charge Current |
40A/60A |
Rated Output Current |
15A |
Self Consumption |
< 10mA |
Bulk Charge |
14.5V(default) |
( *2 for 24Vdc, *4 for 48Vdc) |
Floating Charge |
13.5V(default) |
Equalization Charge |
14.0V(default) |
Over Charge Disconnection |
14.8V |
Over Charge Recovery |
13.6V |
Over Discharge Disconnection |
10.8 V(default) |
Over Discharge Reconnection |
12.3V |
Temperature Compensation |
- 13.2mV/℃ |
Ambient Temperature |
0-40℃(full load) 40-60℃(derating) |
Mechanical Specifications |
Mounting |
Wall mount |
Inverter Dimensions(L*W*H) |
598*218*179mm |
470*190*340mm |
Inverter Weight |
21KG |
22kg |
23KG |
27KG |
38KG |
48KG |
48KG |
Shipping Dimensions(L*W*H) |
740*315*300mm |
530*240*390mm |
Shipping Weight |
23KG |
24kg |
25KG |
29KG |
40KG |
50KG |
50KG |
Display |
Status LEDs / Status LEDs+LCD |
Standard Warranty |
1 Year |
Payment Terms: | TT/LC/Western Union/Cash |
| |
Product Image
Send Inquiry to this Member
Related Products of this Company
This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please
click here.
China Suppliers Quick Searching:
,