Device Introduction
It is a fixed micro-reactor evaluation device of small size, which used for thecatalyst reaction evaluation, including reactor bypass, preheated, pressure-control valve, and other technical pipeline, which in the furnace for preventing condensationof volatile products.This device is configured by accessories of high-medium pressure and selectiveitems, improving working efficiency. It includes electrical system, control system, MFM system and the steam generator, mixer and reactor which are built-in the hot box.The high-voltage reactor system includes the process of gas-liquid separation,which adopts the new device of condensation liquid level, control that nearly close tono dead volume (0.3ml). So the sample of liquid port is the mixer of reactant. Thisreactor could realize much reaction such as hydro cracking, hydro treat, isomerismreactor, hydrogenation, hydrodesulphurization, hydrogenation, dehydrogenation oxidizing reaction,polymerization and steamer forming.
Technique parameter
- Open-type construction, reasonable layout, easy repair
- Sectional pipe furnace, independent temperature control, highest temperature reaches to 1000 the temperature of reactor pipe could be programmed control
- Good warm keeping of Ino304 steel reaction heater
- Reactor Incoel600, highest temperature 1000 ℃, each size tube of the O.D10-50mm can weld the carriage
- Thermocouple with or without the casing pipeline is optional, accurate measurement of temperature
- 6 channels at most, gas flow is controlled by MFC precisely
- 3 liquid channels at most, liquid flow is controlled by high pressure measuring pump, every liquid line is correspond to a steam generator
- Stop valve and check valve are installed respectively with gas pipeline and liquid pipeline, good gas mixer in the gas mixture
- Gas condensation and separation thermoelectric components could be condensate by tap water circulation. Secondary condensing device is available
Liquid feed check valve with 10PSI cracking pressure, protecting MFC accessories
Screw and liquid evaporator or fore warmer, the temperature is controlled independently highest to 200°
Spiral air preheated, mainly for gas preheating and preventing liquid condensation
Ordinary pressure/high pressure sensor equipped with pressure instrument, showing the pressure data real time
Chromatograph connected with 250°heat wire, preventing condensation
Pass RS485 Micro processing safety integrated controller (abnormal flow. Pressure, temperature,
liquid level sensor)
The maximum working pressure to 20MPa, basic unit work pressure 0.3MPa
Pipeline, part and valve connect by cutting ferrule, pressure resistant 20MPa