Model: | HV4000 |
---|---|
Brand: | HET/OEM |
Origin: | Made In China |
Category: | Metallurgy , Mining & Energy / New Energy / Solar Energy |
Label: | solar inverter , 4000w inverter , off grid inverter |
Price: |
US $500
/ pc
|
Min. Order: | 1 pc |
Last Online:13 Dec, 2014 |
HV Series Inverter and Solar Charger HV solar charger is a combination of HC inverter and solar charger. The HV pure sine wave inverter not only makes your solar system simple in wiring, but also has all the unique features from the inverter and solar charger.
Features of HV Pure Sine Wave Inverter, Solar Charger
1. HV pure sine wave inverter adopts low quiescent current, and power saver mode to reduce power consumption to 10W(3s
sensing cycle)/3W(30s sensing cycle). It can extract max. power from various batteries with different protections.
2. High overload ability of our HV charger is up to 300% rated power(20 sec.),and low voltage trip 9.5V/10V or 10V/10.5V is
selectable.
3. Our HV solar charger can achieve reverse current protection and battery temperature compensation, with the high efficiency
MPPT function(97%). Auto input DC voltage can be detected between 12V/24V.
4. Our HV pure sine wave inverter supports 3step intelligent battery charging, and equips with 8 preset battery type selector
for totally flat batteries. Its powerful charge rate up to 90Amp**. In addition, PFC(power factor correction) is adopted for charger,
which has less power consumption than conventional units
5. LCD status display, USB communication port, battery/AC priority switch are available for our HV pure sine wave inverter, it also
has 17 alarms/warnings for easier operation and troubleshooting, and ability to switch the unit on/off. In addition,
select/deselect power saver mode can be used too.
6. The HV solar charger has 15s delay before transfer when AC resumes, and the function of overload protection when it equips
with generator. Also, it allows start up and through power with depleted batteries.
7. 10ms typical transfer time between battery and AC, which guarantees power continuity of HV pure sine wave inverter. Its input
AC voltage is selectable (184-253V or 154-253V) for different kinds of loads.
Electrical Specifications of the HV Series Inverter and Solar Charger
|
Model |
HV 1000W |
HV 1500W |
HV 2000W |
HV 3000W |
HV 4000W |
HV 5000W |
HV 6000W |
Inverter Output |
Continuous Output Power |
1000W |
1500W |
2000W |
3000W |
H4000W |
H5000W |
6000W |
Surge Rating(20s) |
3000W |
4500W |
6000W |
9000W |
12000W |
15000W |
18000W |
|
Output Waveform |
Pure sine wave/Same as input (Bypass mode) |
|||||||
Nominal Efficiency |
>88%(Peak) |
|||||||
Line Mode Efficiency |
>95% |
|||||||
Power Factor |
0.9-1.0 |
|||||||
Nominal Output Voltage rms |
100-110-120Vac / 220-230-240Vac |
|||||||
Output Voltage Regulation |
±10% RMS |
|||||||
Output Frequency |
50/60Hz ± 0.3Hz |
|||||||
Short Circuit Protection |
Yes, Current Limit Function (Fault after 1sec) |
|||||||
Typical Transfer Time |
10ms(Max.) |
|||||||
THD |
< 10% |
|||||||
DC Input |
Nominal Input Voltage |
12.0Vdc |
||||||
(*2 for 24Vdc, *4 for 48Vdc) |
||||||||
Minimum Start Voltage |
10.0Vdc |
|||||||
Low Battery Alarm |
10.5Vdc / 11.0Vdc |
|||||||
Low Battery Trip |
10.0Vdc / 10.5Vdc |
|||||||
High Voltage Alarm & Fault |
16.0Vdc |
|||||||
High DC Input Recovery |
15.5Vdc |
|||||||
Low Battery Voltage Recover |
13.0Vdc |
|||||||
Idle Consumption-Search Mode |
< 25 W when Power Saver On |
|||||||
Charge |
Input Voltage Range |
Wide: 90~135VAC / 164~243VAC; Narrow: 100~135VAC / 194~243VAC |
||||||
Output Voltage |
Depends on battery type |
|||||||
Charger Breaker Rating |
10A |
10A |
10A |
20A |
20A |
30A |
30A |
|
Max Charge Rate |
35A / 70-90A Max (Charger Current Control) |
|||||||
Over Charge Protection Shutdown |
15.7V for 12Vdc (*2 for 24Vdc, *4 for 48Vdc) |
|||||||
Charger Curve (4 stage constant current) 4 step digital controlled progressive charge |
Battery types (*2 for 24Vdc, *4 for 48Vdc) |
|||||||
Battery Type |
Fast V Float V (*2 for 24Vdc, *4 for 48Vdc) |
|||||||
Gel U.S.A |
14 |
13.7 |
||||||
A.G.M 1 |
14.1 |
13.4 |
||||||
A.G.M 2 |
14.6 |
13.7 |
||||||
Sealed Lead Acid |
14.4 |
13.6 |
||||||
Gel Euro |
14.4 |
13.8 |
||||||
Open Lead Acid |
14.8 |
13.3 |
||||||
Calcium |
15.1 |
13.6 |
||||||
De-sulphation |
15.5 for 4hrs |
|||||||
Remote Control |
Yes. Optional |
|||||||
Bypass & Protection |
Input Voltage Waveform |
Sine wave (Grid or Generator) |
||||||
Nominal Voltage |
120VAC / 230VAC |
|||||||
Low Voltage Trip |
90V±4%/184V/154V±4% |
|||||||
Low Voltage Re-engage |
100V±4%/194V/164V±4% |
|||||||
High Voltage Trip |
140V±4%/ 253V±4% |
|||||||
High Voltage Re-engage |
135V±4%/243V±4% |
|||||||
Max. Input AC Voltage |
150VAC/270VAC |
|||||||
Nominal Input Frequency |
50Hz or 60Hz (Auto detect) |
|||||||
Low Freq. Trip |
47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz |
|||||||
Low Freq Re engage |
48±0.3Hz for 50Hz, 58±0.3Hz for 60Hz |
|||||||
High Freq. Trip |
55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz |
|||||||
High Freq. Re-engage |
54±0.3Hz for 50Hz, 64±0.3Hz for 60Hz |
|||||||
Output Short Circuit Protection |
Circuit breaker |
|||||||
Short Circuit Protection |
Circuit breaker |
|||||||
Transfer Switch Rating |
30amp |
40amp |
||||||
Max. Bypass Current |
30amp |
40amp |
||||||
Bypass Over Load Current |
35amp: Alarm |
45amp: Alarm |
||||||
Solar Charger |
Rated Voltage |
12V/24V/48V |
||||||
Rated Charge Current |
40A/60A |
|||||||
Rated Output Current |
15A |
|||||||
Self Consumption |
< 10mA |
|||||||
Bulk Charge |
14.5V(default) |
(*2 for 24Vdc, *4 for 48Vdc) |
||||||
Floating Charge |
13.5V(default) |
|||||||
Equalization Charge |
14.0V(default) |
|||||||
Over Charge Disconnection |
14.8V |
|||||||
Over Charge Recovery |
13.6V |
|||||||
Over Discharge Disconnection |
10.8 V(default) |
|||||||
Over Discharge Reconnection |
12.3V |
|||||||
Temperature Compensation |
- 13.2mV/℃ |
|||||||
Ambient Temperature |
0-40℃(full load) 40-60℃(derating) |
|||||||
Mechanical Specification |
Mounting |
Wall mount |
||||||
Inverter Dimensions(L*W*H) |
598*218*179mm |
470*190*340mm |
||||||
Inverter Weight |
21KG |
22KG |
23KG |
27KG |
38KG |
48KG |
48KG |
|
Shipping Dimensions(L*W*H) |
740*315*300mm |
530*240*390mm |
||||||
Shipping Weight |
23KG |
24KG |
25KG |
29KG |
40KG |
50KG |
50KG |
|
Display Status |
LEDs / Status LEDs+LCD |
|||||||
Standard Warranty |
1 Year |