Model: | ZHV |
---|---|
Brand: | ZNX |
Origin: | Made In China |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | AC/DC hipot tester , withstand voltage |
Price: |
¥2042
/ pc
|
Min. Order: | 1 pc |
Last Online:17 Dec, 2014 |
Type | AC/DC | Output voltage | Leakage current | Alarm current |
ZHV-5 | AC | AC0-5kV | AC20mA | AC0.5-20mA |
ZHV-5 | AC | AC0-5kV | AC100mA | AC0.5-100mA |
ZHV-5 | AC | AC0-5kV | AC200mA | AC0.5-200mA |
ZHV-5 | AC/DC | AC0-5kV/DC0-5kV | AC20mA/DC10mA | AC0.5-20mA/DC0.5-10mA |
ZHV-5 | AC/DC | AC0-5kV/DC0-5kV | AC100mA/DC20mA | AC0.5-100mA/DC0.5-20mA |
ZHV-10 | AC | AC0-10kV | AC20mA | AC0.5-20mA |
ZHV-10 | AC | AC0-10kV | AC100mA | AC0.5-100mA |
ZHV-10 | DC | DC0-10kV | DC20mA | DC0.5-20mA |
The withstand voltage test device is applicable for various motors、appliances、instrumentation and household appliances,as well as the safe withstand voltage of strong electric system and leakage current test. It is easy to operate, safety and stable, fine performance, convenient maintenance. It is required test device which conforms to GB4706.1 (Home use and similar use electric appliance safety general requirement ) and GB9706.1 (Medical electrical safety general requirement ) as well as GB4943、GB4793 etc relative provisions of national standards.
1,Digital display.
2,Display leakage current value of being tested equipment on testing.
3,Time preset and display,test time countdown.
4,Arbitrarily set alert current value.
5,Output waveform is 50Hz sine wave or DC.
(1) Output voltage, basic error, leakage current, preset alarm current and tolerance.
Capacity:0.5kVA
Output voltage:AC0-5kV basic error±5% ±(5%r+3d)
Leakage current:0-20mA tolerance±5% ±(5%r+3d)
Alert current:0.5-20mA tolerance±5% ±(5%r+3d)
Note 1: r-reading d-digit.
Note 2: Basic error and tolerance test condition environment & temperature is 23℃±5℃, RH is no more than80%
Can define refer to below table
(2)、Test time、apparent size and weight
Test time:1-99s
Volume:L:380×W:325×H:205
Weight:13.5 kg
(3)、Use conditions
Temperature 0℃~40℃ RH <=80%
There are no strong electromagnetic interference around, no large quantities of dust and corrosive gas, and well-ventilated.
(4)、Power supply AC - 220V Tolerance ±10%,50Hz.