Model: | CT-4002-60V40A |
---|---|
Brand: | NEWARE |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument |
Label: | Battery tester , Battery charging , battery test system |
Price: |
-
|
Min. Order: | 1 pc |
Last Online:04 Nov, 2019 |
Battery charging station for EV battery CT-4002-60V40A
BTS4000 is based on Neware 4thgeneration testing system, and was introduced into the market in 2008. It's the upgrade version of the most popular battery test equipment series of BTS3000.
BTS4000 applies all the applications of BTS3000, plus EV battery pulse test, HPPC test and DCIR (direct current internal resistance) test.
Comparing with BTS3000, BTS4000 greatly improved the hardware response time, data acquisition frequency and result accuracy.
BTS4000 is the perfect test system in Neware's line of high quality, dependable test systems.
BTS4000 can be configured with multi-current range channels, which have a current control range of 0A to 3000A. These multi-current range channels can be configured for voltage ranges of 0V to 110V. The accuracy for current and voltage on these channels is ± 0.05% FS.
BTS4000 is now widely used by research institutes, colleges and universities and EV battery manufacturers all around our country.
BTS 4000 entered into market in the year of 2008. Now it is one of the most successful and most popular battery testing system in China. Thousands of battery manufacturers, battery research institutes and laboratories use it as their primary testing partner for their various testing activities.
Battery charging station techncial information:
BTS-60V40A | Battery Testing System | |||||||||||||||
Model: | BTS- | 60 | V | 40 | A | Material Code: | CT-4002 | -60V40A | - | NTA | - | P | ||||
Description | Product Specification | |||||||||||||||
AC Input | AC 380V ±10% / 50Hz | |||||||||||||||
Power | 6613 | W | ||||||||||||||
Resolution | AD: 16bit; DA: 16bit | |||||||||||||||
Impedence Input | ≥1MΩ | |||||||||||||||
Voltage | Measuring Range | Charge: 300mV~60V | Dischrge: 300mV~60V | |||||||||||||
Discharge Min Voltage | 2.5V | |||||||||||||||
Accuracy | ± 0.1% of FS | |||||||||||||||
Stability | ± 0.1% of FS | |||||||||||||||
Current | Range | Charge: 200mA~40A Discharge: 200mA~40A | ||||||||||||||
Accuracy | ± 0.1% of FS | |||||||||||||||
Stability | ± 0.1% of FS | |||||||||||||||
Power | Output Power Per Channel | 2400W | ||||||||||||||
Stability | ±0.2% of FS | |||||||||||||||
Time | Rise Time | 20ms (10%FS~90%FS) | ||||||||||||||
Step Time | ≤ (365*24) hours/step | Time Format 00:00:00:000 ( h:min:s:ms ) | ||||||||||||||
Aux Channel | Aux Input | Temperature | ||||||||||||||
Temperature | ﹣25℃~110℃ | |||||||||||||||
Temperature Accuracy | ±2℃ | |||||||||||||||
Temperature Resolution | 0.1℃ | |||||||||||||||
Voltage Range | ||||||||||||||||
Voltage Accuracy | ||||||||||||||||
Data Accquisition | Intervals | Time Interval Δt: (100ms~60000s) | ||||||||||||||
Voltage Interval ΔU: (120mV~60V) | ||||||||||||||||
Current Interval ΔI: (80mA~40A) | ||||||||||||||||
Frequency | 10Hz | |||||||||||||||
Charge | Modes of Operation | CCC, CVC, CC & CVC, CPC | ||||||||||||||
End Conditions | Main Channel: Voltage, Current, Test Time, Capacity | |||||||||||||||
Aux: Temperature | ||||||||||||||||
Discharge | Modes of Operation | CCD, CPD, CRD | ||||||||||||||
End Conditions | Main Channel: Voltage, Current, Test Time, Capacity | |||||||||||||||
Aux Channel: Temperature | ||||||||||||||||
Pulse | Charge | CCC | ||||||||||||||
Discharge | CCD | |||||||||||||||
Minimum Pulse Width | 500ms | |||||||||||||||
Automated Switch | Automated switch from charge to discharge for each pulse | |||||||||||||||
End Condition | Voltage, Test Time | |||||||||||||||
Cycle | Cycles | Max 65535 | ||||||||||||||
Steps | 254 | |||||||||||||||
Nested Fuction | Max three levels of loops | |||||||||||||||
Protective Function | Software | ● Power-off data protection | ||||||||||||||
● Off-line Operating | ||||||||||||||||
● Main Channels: user-defined safety(upper and lower)tolerance of current, voltage and delay time | ||||||||||||||||
●Aux Channels: User-defined safety (upper and lower) tolerance of temperature | ||||||||||||||||
Hardware | Reverse-connecting protection | |||||||||||||||
Channel Features | Independent pairs of closed loops for constant current source and constant voltage source | |||||||||||||||
Channels | Independent Control | |||||||||||||||
Detection and Sampling | 4-wire Connecting | |||||||||||||||
Noise Density | <85dB | |||||||||||||||
Data Management | MYSQL Database | |||||||||||||||
Communication Means | TCP/IP Protocol | |||||||||||||||
Export Formats | EXCEL2003、2010,TXT,Graph | |||||||||||||||
Communication Interface | Ethernet Port | |||||||||||||||
Number of Channels Per Cabinet | 2 | |||||||||||||||
Assignable Aux Temperature Per Channel | Max 248 | |||||||||||||||
Operating Environment | ||||||||||||||||
Description | Product Specification | |||||||||||||||
Operating Temperature | 0℃~40℃ | |||||||||||||||
Storage Temperature | -10℃~50℃ | |||||||||||||||
Operating Humidity | ≤70% RH | |||||||||||||||
Storage Humidity | ≤80% RH |