Model: | - |
---|---|
Brand: | BAOSHIDA |
Origin: | Made In China |
Category: | Electronics & Electricity / Optical Fiber, Cable & Wire / Electric Wire & Cable |
Label: | shipboard cable , BAOSHIDA , manufacturer |
Price: |
US $80
/ meter
|
Min. Order: | 1 meter |
Last Online:05 Jan, 2017 |
XLPE insulated shipboard power cable, type DA, SA
XLPE insulated low-smoke, halogen-free and flame retardant shipboard power cable, type SC
XLPE insulated fire resistance and flame retardant shipboard power cable, type SNA, SNC
Application:
The XLPE insulated shipboard/marine power cable with rated voltage up to and including 0.6/1kV is applicable for all kinds of shipboards and over-water buildings like petrol platform at sea.
Operation Properties:
Rated voltage of cable:0.6/1kV.
Continuous permissible operating temperature: 85℃.
Min bending radius under installation
Metal braid armored type:6D;
Non-armored type:4D≤25
6D>25
Execution Standard:
Type |
Execution Standard |
||||
DA Type |
SA Type |
SC Type |
SNA Type |
SNC Type |
|
CJV/SA/DA/SNA
|
IEC60092-351
|
IEC60092-351
|
— |
IEC60092-351
|
— |
CJPJ/SC/SNC
|
— |
— |
IEC60092-351
|
— |
IEC60092-351
|
Specifications:
Type (DA/SA/SB/SC/SNA) |
No. of cores |
Nominal cross-sectional area mm² |
All Types |
1 |
1—300 |
2 |
1—120 |
|
3 |
1—185 |
|
4—37 |
1—2.5 |
Type and Name:
Type |
Name |
CJV/SA/DA/SNA |
XLPE insulated PVC sheathed shipboard power cable, type DA、SA、SNA |
CJV80/SA/DA/SNA |
XLPE insulated PVC inner sheathed bare tinned copper braid armored shipboard power cable, type DA、SA、SNA |
CJV82/SA/DA/SNA |
XLPE insulated PVC inner sheathed tinned copper braid armored and PVC outer sheathed shipboard power cable , type DA、SA、SNA |
CJV90/SA/DA/SNA |
XLPE insulated PVC inner sheathed bare zinc plated steel wire braid armored shipboard power cable, type DA、SA、SNA |
CJV92/SA/DA/SNA |
XLPE insulated PVC inner sheathed zinc plated steel wire braid armored and PVC outer sheathed shipboard power cable, type DA、SA、SNA |
CJPJ/SC/SNC |
XLPE insulated PO sheathed low-smoke, halogen-free (LSOH) and flame-retardant shipboard power cable, type SC、SNC |
CJPJ80/SC/SNC |
XLPE insulated PO inner sheathed bare tinned copper braid armored low-smoke, halogen-free (LSOH) and flame-retardant shipboard power cable, type SC、SNC |
CJPJ86/SC/SNC |
XLPE insulated PO inner sheathed tinned copper braid armored and PO outer sheathed low-smoke, halogen-free(LSOH) and flame-retardant shipboard power cable, type SC、SNC |
CJP90/SC/SNC |
XLPE insulated PO inner sheathed bare zinc plated steel wire braid armored low-smoke, halogen-free(LSOH) and flame-retardant shipboard power cable, type SC、SNC |
CJPJ96/SC/SNC |
XLPE insulated PO inner sheathed zinc plated steel wire braid armored and PO outer sheathed low-smoke ,halogen-free(LSOH) and flame-retardant shipboard power cable, type SC、SNC |
Main Technical Properties
DC resistance and insulated resistance of conductor
The second class of Conductor
Nominal cross-sectional area mm² |
DC resistance of Conductor
|
XLPE Insulation resistance ≥ MΩ/km |
|
20℃ |
|
||
1 |
18.2 |
1077 |
1.077 |
1.5 |
12.2 |
949 |
0.949 |
2.5 |
7.56 |
785 |
0.785 |
4 |
4.70 |
664 |
0.664 |
6 |
3.11 |
567 |
0.567 |
10 |
1.84 |
458 |
0.458 |
16 |
1.16 |
376 |
0.376 |
25 |
0.734 |
385 |
0.385 |
35 |
0.529 |
331 |
0.331 |
50 |
0.391 |
318 |
0.318 |
70 |
0.270 |
294 |
0.294 |
95 |
0.195 |
254 |
0.254 |
120 |
0.154 |
246 |
0.246 |
150 |
0.126 |
258 |
0.258 |
185 |
0.100 |
264 |
0.264 |
240 |
0.0762 |
246 |
0.246 |
300 |
0.0607 |
233 |
0.233 |
Main Technical Properties:
No. |
Technical Properties |
Type DA |
Type SA |
Type SNA |
Type SC |
Type SNC |
1 |
D.C. resistance of Conductor(Ω/km) |
See above table |
||||
2 |
Insulation resistance(Ω/km) |
See above table |
||||
3 |
Power frequency voltage test for 4h |
Insulated and no breakdown at 3.5kV |
||||
4 |
XLPE insulation hot set test |
≤175% |
||||
5 |
Single vertical burning test |
IEC60332-1 |
— |
|||
6 |
Bundled burning test |
|
IEC60332-3(A type) |
|||
7
|
Burning smoke density test
|
— |
— |
— |
60% |
|
8 |
Fire resistance test |
|
|
No breakdown for 90min at 750℃ |
|
|
9 |
Burning gas corrosion test |
|
— |
— |
||
9.1 |
HCL Content (mg/g) |
— |
— |
— |
Not more than 5 |
|
9.2 |
PH value |
|
Not less than 4.3 |
|||
9.3 |
Conductibility (μs/mm) |
|
Not more than 10 |
Referenced current carrying capacity for continues operating
Referenced current carrying capacity for the cable of single core and three cores
Nominal cross-sectional area |
Referenced current carrying capacity |
|
Single Core |
Three Cores |
|
10 |
82 |
71 |
16 |
103 |
92 |
25 |
132 |
113 |
35 |
160 |
132 |
50 |
193 |
155 |
70 |
244 |
197 |
95 |
296 |
240 |
120 |
338 |
273 |
150 |
385 |
310 |
185 |
442 |
— |
240 |
522 |
— |
300 |
602 |
— |
400 |
700 |
— |
500 |
804 |
— |
630 |
921 |
— |
Temperature for continues operating |
85℃ |
|
Surrounding temperature |
45℃ |
Correction factors at different ambient air temperatures:
the highest permission temperature for conductor |
Correction factors at different ambient air temperature |
||||||||||
35℃ |
40℃ |
45℃ |
50℃ |
55℃ |
60℃ |
65℃ |
70℃ |
75℃ |
80℃ |
85℃ |
|
60℃ |
1.29 |
1.15 |
1.0 |
0.82 |
— |
— |
— |
— |
— |
— |
— |
65℃ |
1.22 |
1.12 |
1.0 |
0.87 |
0.71 |
— |
— |
— |
— |
— |
— |
70℃ |
1.18 |
1.10 |
1.0 |
0.89 |
0.77 |
0.63 |
— |
— |
— |
— |
— |
75℃ |
1.15 |
1.08 |
1.0 |
0.91 |
0.82 |
0.71 |
0.58 |
— |
— |
— |
— |
80℃ |
1.13 |
1.07 |
1.0 |
0.93 |
0.85 |
0.76 |
0.65 |
0.53 |
— |
— |
— |
85℃ |
1.12 |
1.06 |
1.0 |
0.94 |
0.87 |
0.79 |
0.71 |
0.61 |
0.50 |
— |
— |
90℃ |
1.12 |
1.06 |
1.0 |
0.94 |
0.88 |
0.82 |
0.74 |
0.67 |
0.68 |
0.47 |
— |
95℃ |
1.10 |
1.05 |
1.0 |
0.95 |
0.89 |
0.84 |
0.77 |
0.71 |
0.63 |
0.55 |
0.45 |