Home > Products > Electronics & Electricity > Electronic Instrument > Other Electronic Instrument

Modbus to HART Gateway 1Modbus to HART Gateway 2Modbus to HART Gateway 3Modbus to HART Gateway 4Modbus to HART Gateway 5
  • Modbus to HART Gateway 1
  • Modbus to HART Gateway 2
  • Modbus to HART Gateway 3
  • Modbus to HART Gateway 4
  • Modbus to HART Gateway 5

Modbus to HART Gateway

Model:G0310
Brand:Microcyber
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Other Electronic Instrument
Label:modbus gateway , hart gateway , gateway converter
Price: US $220 / pc
Min. Order:1 pc
Inquire Now

Member Information

Detail

Microcyber Corporation

Free MemberLiao Ning - China
Last Online:22 Jun, 2020

Product Description

Description

G0310 Modbus to HART Gateway, designed by Microcyber Corporation is a gateway device for Modbus-RTU protocol and HART protocol. As Modbus master, G0310 Modbus to HART Gateway communicates with devices that have Modbus-RTU communication function via RS485 interface. It can convert device data to HART device variables output, and it also supports 4~20mAcurrent output.

Features

Be tallied with HART7.0

HART slave and Modbus master mode

4~20mA analog signal overlay HART digital signal

Support 1 Modbus slave device

Support 6 device variables and 4 dynamic variables

Configure gateway by HART interface

Write protect user data

Support high/low alarm current

RS485 Modbus interface

LED power and communication indicating

Standard DIN rail installation

Modbus-RTU protocol to HART protocol

Support 6 device variables and 4 dynamic variables

Support Modbus communication parameters dynamic configuration

Support HART multipoint mode

Support 375/475 communicator

Parameters

measurement object Modbus RTU slave device
Power 1242VDC
Bus Protocol 2-wire420mA+HART
Load resistance

01500Ω420mA

2301100ΩHART communication

Isolation Voltage Modbus and HART Bus Interface500VAC
Temperature Range -40℃85℃
Humility Range 595%RH
Start Time ≤5s
Refresh Time 0.2s
Damping adjustment Time constant 032s

 


Product Image

Modbus to HART Gateway 1
Img 1
Modbus to HART Gateway 2
Img 2
Modbus to HART Gateway 3
Img 3
Modbus to HART Gateway 4
Img 4
Modbus to HART Gateway 5
Img 5

Send Inquiry to this Member

Microcyber Corporation

wensu street hunnan new district

Phone:
86-024-31217280
Fax:
中国
Contact:
Yvette Jiang (Sales Manager)
Mobile:
18304037682

Related Products of this Company

This member assumes full responsibility for the content of this listing. DIYTrade accepts no responsibility whatsoever in respect of such content.
To report fraudulent or illegal content, please click here.

China Suppliers Quick Searching:

Other Electronic Instrument Made In China Products

,  

Other Electronic Instrument China Suppliers and China Manufacturers