Model: | Winner 2000ZD |
---|---|
Brand: | Winner |
Origin: | Made In China |
Category: | Industrial Supplies / Other Industrial Supplies |
Label: | size analyzer |
Price: |
US $13692
/ pc
|
Min. Order: | 1 pc |
Last Online:13 Oct, 2023 |
Product Description
Winner2000ZD intelligent laser particle size analyzer, perform auto test, auto alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion, auto cleaning etc., really realize one-key operation. It adopt full built-in sampling system, effectively prevents large particles sedimentation problems in the circulation pipeline, ensure good accuracy. It adopts comprehensive Laser diffraction particle size measurement principle with highly sensitive ring photoelectric detector improving the test accuracy greatly, Original designed unconstrained free fitting software technology, a true reflection of the particle size distribution, to ensure truth and accuracy of the test results. Therefore especially suits the laboratories of enterprises, colleges and universities and research institutes to use.
Model Name |
Winner2000ZDE |
Winner2000ZD |
|
Standard |
ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009 |
||
Principle |
MIE scattering principle |
||
Measuring Range |
0.1μm-300μm |
0.1-40μm/0.6-120μm/1-300μm |
|
Channels Number |
78 pcs |
76*3 pcs |
|
Accuracy error |
<1% (National Standard Sample D50 ) |
||
Repeatability error |
<1% (National Standard Sample D50 ) |
||
Light source |
High performance He-Ne Laser (λ= 632.8nm, P>2MW)
|
||
|
Ultrasonic |
Frequency:40KHz Power:35W, Time: ≥1S |
|
Stir |
Revolutions Speed: 0-3000RPM (Adjustable) |
||
Circulate |
Rated Flow:8L/min Rated Power:10W |
||
Sample Pool |
Volume:350mL |
||
Micro-
|
Volume: 10mL ( Available) |
||
Operation Mode |
Full automatic and manual control, freely choose |
||
Output parameter |
D10,D50,D90,D100,S/V referent parameters |
||
Optical Calibration System |
Full automatic |
||
Test Speed |
<2mins for each time |
||
Volume |
L88cm×W39cm×H46cm |
||
Net Weight |
41Kg |
Main Features:
1,Advanced design of light path: A patented technique of Fourier transform of converging light released the scattered light at large-scattering-angles from the restriction of the aperture of the Fourier lens. The focal length is reduced to enhance the resolution of the instrument.
2,Built-in dispersion units: We carefully aligned the stirring set-up, the ultrasonic dispersing unit and the sample circulation pipes, and fixed them inside the instrument. Such a built-in design effectively prevents the inhomogeneous dispersion and sedimentation of big particles, which can be observed in the designs that these dispersing units are separated from the instruments, where the sample circulation pipes are therefore too long, The sample will be sufficiently dispersed.
3,Unconstrained fitting techniques: The particle analysis software uses a unique unconstrained data fitting technique that we developed to obtain data of unknown size distribution, this is particularly important for researchers.
4,Micro sample chamber (optional): The capacity of the sample chamber is as small as only 10ml. This helps with measuring expensive/precious samples, or samples difficult to be dispersed within medium.
5,Modern measurement control: Users can perform all measurement procedures by simply operating on the PC and have ideal results in a very short time.
6,User-friendly Operation: manual mode and the automatic mode, freely choose, to measure according to the sample features. In some conditions (e.g. the sample have unknown features or there are special requirements for the measurements), users can make a test measurement in the manual mode first, and after having an idea of the sample features and the measurement conditions, measure the samples in the automatic mode.
7,Fully automatic light path alignment: A precise four phase hybrid stepping motor automatically aligns the optical path and can adjust it at any moment. This releases users from manual adjusting the optical path and improved accuracy
FAQ
Purchase laser particle size analyzer need know points:
(1) What materials need test?
If suspension/emulsion, must choose liquid dispersion particle size analyzer, and some materials are also reacted with water, so need liquid dispersion particle size analyzer also. Generally, cement, metal powders and pharamcy materials need dry dispersion model particle size analzyer.
(2) What size range need test?
By now, Based on MIE scattering, laser particle size analyzer can test the particle range is 0.01um-2000um.
If materials range is not so wide, for example, 10um-20um, smaller range of particle size distributon choose closer range model will be preciser, no need to buy large range model.
(3) What is dispersion media?
For liquid model, in order that sample can disperse well and circualte in the laser particle size analyzer, generally we need use water, alochol or organic solvent as dispersion media.For dry dispersion model, just use compressed air as dispersion media.In the current market, Dry laser particle size analyzer cost is higher than liquid dispersion models, so if can test well, liquid model is better.
Certifications