LONZA公司LAL檢測附屬產品(Accessory Products)
內毒素標準品- Endotoxin (E. coli) Standards
Control Standard Endotoxin is referenced against the USP Reference Standard Endotoxin following the procedures set forth in the "Guideline on Validation of the Limulus Amebocyte Lysate Test as an End-Product Endotoxin Test for Human and Animal Parenteral Drugs, Biological Products and Medical Devices".
N186 is intended for use as the control standard endotoxin in PYROGENT? Gel Clot assays. N185 contains high potency endotoxin and is intended for use in endotoxin removal system challenges, i.e. depyrogenation ovens, and other spiking studies. E50-640 is intended for use with QCL-1000? assays and contains E. coli strain 0111:B4.
Price |
||
N185 |
Endotoxin, E. coli O55:B5 2.5 mg/vial |
|
N186 |
Endotoxin, E.coli O55:B5 10 ng/vial |
|
E50-640 |
ENDOTOXIN FOR QCL-1000 1 VIAL |
|
內毒素挑戰管- Endotoxin (E. coli) Challenge Vials
For use in oven validation studies, contains >1000 EU/vial. The vials may be tested using any of our endotoxin detection kits.
Price |
||
N187 |
Endotoxin Challenge Vials E.coli Endotoxin |
|
氯化鎂溶液- MgCl2, 10mM Solution
MgCl2 should be used as the sample diluent when attempting to overcome inhibitory chelation effect. Examples of samples which chelate divalent cations include heparin and EDTA. MgCl2 may be used to prepare samples for any LAL assay. Contains <0.005 EU/ml endotoxin.
Price |
||
S50-641 |
MgCl2, 10mm Solution For Use with LAL |
|
Tris緩衝液- Tris Buffer, 50 mM Solution
Tris buffer is to be used in place of water as the sample diluent for highly acidic or basic samples (samples and sample dilutions should be between pH 6-8). Tris buffer may be used to prepare samples for any of our endotoxin detection assays. Contains <0.005 EU/ml endotoxin.
Storage: 2°C - 30°C
Price |
||
S50-642 |
Tris Buffer,50mM Solution For Use with LAL |
|
LAL反應水- LAL Reagent Water
Recommended for reconstituting LAL reagents and the dilution of control standard endotoxin and test samples for endotoxin testing. Contains <0.005 EU/ml endotoxin.
Price |
||
W50-640 |
LAL Reagent Water- 30ml |
|
W50-100 |
LAL Reagent Water - 100ml |
|
W50-500 |
LAL Reagent Water - 500ml |
|
無熱源檢測管- Pyrogen-free test tubes
All test tubes are made from USP Type 1 flint borosilicate glass. Contain less than 0.005 EU/ml endotoxin.
Product number N207 is recommended for dilution of endotoxin standards and test samples for all endotoxin detection assays. Product numbers N201 and N205 are recommended for use as reaction tubes in gel clot assays.
Price |
||
N201 |
Pyrogen-Free Test Tubes 10x75 mm w/Screw Caps |
|
N207 |
Pyrogen-Free Dilution Tubes 13x100mm w/o Caps |
|
N205 |
Pyrogen-Free Test Tubes 10x75mm w/o Screw Caps |
|
Eppendorf®吸頭- Eppendorf® BioPur Pipette Tips
These tips are to be used when testing with any of our LAL systems. The tips are certified to contain <0.001 EU/ml endotoxin. The new design of the tips allows more flexibility with different pipettors.
Price |
||
25-415 |
EPPENDORF BIOPUR TIPS 200 UL |
|
25-416 |
EPPENDORF BIOPUR TIPS 300 UL |
|
25-417 |
EPPENDORF BIOPUR TIPS 1000 UL |
|
LAL反應多孔板- LAL Reagent Grade Multi-well Plates
These 96-well plates can be used with the QCL-1000® Chromogenic Endpoint Assay, Kinetic-QCL® Kinetic Chromogenic and PYROGENT-5000® Kinetic Turbidimetric LAL assays. The plates are certified to contain <0.0005 EU/well endotoxin. Each case contains 50 individually wrapped plates.
Price |
||
25-340 |
LAL REAGENT GRADE MULTI-WELL PLATES |
|
ß-葡聚糖阻滯液- ß-Glucan Blocker
ß-1,3-Glucans can produce false positive results in LAL assays. Some examples of glucan sources include yeast and cellulosic materials including hemodialysis filters. Our ß-G-Blocker may be used with any of our LAL assays. Note: PYROGENT® Gel Clot lysate products typically do not require ß-glucan blocker.
Price |
||
N190 |
Beta-G-Blocker Kit |
|
分散劑- Pyrosperse® Dispersing Agent
Pyrosperse® helps eliminate endotoxin binding or masking in some samples, solving problems of inhibitory behavior. Examples of samples that may show endotoxin binding behavior include plasma protein fractions, electrolyte solutions, and lipid emulsions. Pyrosperse may be used with any of our LAL Kits.
Price |
||
N188 |
Pyrosperse Kit Dispersing Reagent |
|
板- Stepped Neutral Density Plate
For Elx808LBS and KQCL readers. The stepped neutral density plate is used for optical density validation of the reader and may be used with WinKQCL® Software.
Price |
||
25-342 |
SND PLATE |
|
帶蓋鋁塊- Ground aluminum block, with lid
Price |
||
25-038 |
ALUMINUM BLOCK W/LID |
|
試劑儲存容器- Reagent Reservoir
Price |
||
25-364 |
Reagent Reservoirs, 10/pk |
|
無熱原樣本儲存容器- Sample Container, Depyrogenated
A 10 ml screw cap vial for transporting product samples for endotoxin analysis or sample storage.
Price |
||
80-507L |
SAMPLE VIAL, PYROGEN-FREE 25/KIT |
|
80-507U |
SAMPLE VIAL, PYROGEN-FREE 100/KIT
北京畢特博生物技術有限責任公司 http://www.bitebo.com
|
|
北京畢特博生物技術有限責任公司 | |
---|---|
國家/地區︰ | 北京市海淀区 |
經營性質︰ | 貿易商 |
聯繫電話︰ | 13366202681 |
聯繫人︰ | 張鈺 (銷售) |
最後上線︰ | 2017/01/09 |