Standard Chromatograph

Standard Chromatograph
Model:FINEGC-1200
Brand:finetec
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Analysis Instrument
Label:standard chromatogra , lab equipment , gas chromatograph
Price: -
Min. Order:1 pc

Product Description

Module design, colorful touch screen controlled design
Plug and play detector
Shockproof shell design
Standard deviation <5%, precision: 5%RSD ( relative standard deviation)
6-7 pieces of plug and play detectors optional, each same or different detector can be composed both independently or combined installation is available, can be equipped with any two same or different plug and play detectors, realize efficient complementation.
Temperature of furnace reaches to 325℃
Equipped with gas sample automatic collector, liquid and solid head space sample heater, transportable gas cylinders
Sensitivities: benzene: ≤0.1ug/L (liquid)
Work environmental temperature: -5~40℃, humidity: 0-95%, non-condensing
Heating gradient of the furnace: 80℃/min, the maximum heating ratio of the column temperature is 25℃/min
Controlling precision of the column temperature reaches to 0.001℃
Fast cooling of temperature column (325-50℃),≤4 min,
Furnace wind tunnel type of design, programmed controlled cooling, fast cooling
Windows XP GC, which can run among the enterprises net compatible work
Remote control the data of GC via LAN/WAN/VPN
For VOC the retention time is <30 sec, for SVOC which is <50 sec.
Sampler injection repeatability is <3%RSD peak area, retention time error is <1%RSD
Data base of >44000 kinds of elements, of which the green ones >1000 kinds.

Electronic Mode
Plug and play controller, furnace and detector
Input and GC storage by touch screen
Displaying all the actual and setting value of GC parameter
Clients’ parameter setting has protection function for permission
Furnace temperature controlled program has multiple kinds of gradient for selections
Carrier gas controlled program has multiple grades
Switch control of relay and solenoid valve of time order
All the parameters for detectable probe displaying in single screen
Two electric pressure controllers
Atmospheric pressure and temperature compensation
EPC controlled resolution ratio reaches 0.1Kpa
Micro processer control
Digital signal of the detector output
Universal voltage input: 220VAC, filtering and changing via linear
Source: 336W(48VDC ×7AMPS)
DC electrical source available
 
Basic Features:
Plug and play module design
Multiple standards application specific profiles
Compact electronic furnace and shockproof design
Colorful touch screen controlled design
Continuous operation by internal GC
Patent digital signal process
Internal diagnostic program
Electric pressure controller precision: 0.001KPaf
Furnace resists 325℃ environmental temperature
Temperature gradient of furnace is 80℃/min, heating speed reaches to 80℃/min in maximum, moment heating ratio can reach 25℃/sec, temperature controlled precision is ±0.001°C
Fast cooling (325 to 50℃). ≤4 min,
Compact and light design
Water resistant briefcase size (52×40×21cm)
Weight: about 10kg
One or two compact gas cylinder (purchase independently available)
 
Detector:
Accuracy: <10%, precision: 5% RSD
Both independent and combined installations are available
0.1℃ resolution ratio, maximum temperature is 300℃
Realize 24 digit output via USD port
EPC pressure controlled precision: 0.1KPa
 
Available Detector:
FID-------flame ionization detector (100×10-9g limit)
PID-------photo ionization detector (10×10-9g limit)
TCD------thermal conductivity detector (1×10-6g limit)
HID-------hydrogen ionization detector (100×10-9g limit)
NPD------ nitrogen-phosphorus detector (20×10-9g limit)
TID--------thermal detector (20×10-9g limit)
ECD-------electron capture detector (0.1×10-9g limit)
 
Furnace Module:
Temperature resistant up to 325℃ column temperature
Temperature gradient of the furnace 80℃/min
Fast cooling (325 to 50℃), ≤4 min,
200W heating element
Multiple temperature gradient set, precision is 0.1℃
Appearance size: 12.5×10.5×12.5cm
Single electron sample valve is available
Source: car inventor (convertor equipped), external handled rechargeable battery
 
Sample Injector:
One or two optional installation
Shunt or nun-shunt calibration, gas sample needn’t heat
Circular injection tube cooling
Multiple gradient set, precision is 0.1KPa
Equipped with two control solenoid
 
Digital Communication:
Two-way connection general data system
USB digital signal output
 
Network Connection
GC of operating Windows XP works in enterprise net compatible network
The computer of ETX structure can be used in the GC control and data read
Applying the web of Windows network protocol for web connection
LAN/WAN/VPN remote controlled GC data read
Standard Chromatograph  1

Member Information

Zhejiang Finetec Instruments Co., Ltd
Country/Region:Zhe Jiang - China
Business Nature:Manufacturer
Phone:15812135702
Contact:shiryhu (assistant)
Last Online:23 Sep, 2014