IEC60061 Go and Not go gauge

IEC60061 Go and Not go gauge
Model:IEC60061-3系列
Brand:HKCX
Origin:Made In China
Category:Electronics & Electricity / Electronic Instrument / Balance & Scale Apparatus
Label:IEC60061 Lamp Gauge , Go and Not go gauge
Price: US $500 / pc
Min. Order:1 pc
Inquire Now

Product Description

GU10 lamp gauge
 GU10 (7006-121-1) was used to test the following items

 Dimension A detection lamp single pin

 2. Detection feet distance and pin diameter (dimension A and D)
 3. Inspection lamp pin length
 Inspection lamp pin recess length the F2 and pin the size of E

E5 lamp gauge
E5 lamp through Regulation 7006 25D-1 regulations only 7006-25E-1

 

E10 lamp holder gauge
Through regulation of E10 lamp holder 7006-27A of the regulations only 7006-28E-2

 

 E14 lamp holder gauge
 E14 lamp holder, E14 Lamp pass regulations 7006-27F-1
 E14 lamp holder ended Regulations 7006-28B-1
 E14 lamp holder to prevent accidental contact gauge 7006-55-1
 Through regulation of E14S1 Lamp 7006-27G-1
 E14 lamp holder contact energy regulation 7006-54-1
 E14 lamp holder torsion test gauge IEC60968Fig2

 


E17 lamp holder gauge
E17 lamp holder through regulation 7006-27K-1
Only regulation 7006-28F-1
Contact Performance Regulations 7006-26D-1

 

 

E27 lamp gauge

“GO” GAUGE FOR E27 CAPS ON FINISHED LAMPS, Cód. 7006-27B-1

."NOT GO" GAUGE FOR E27 CAPS ON FINISHED LAMPS, Cód. 7006-28A-1

.GAUGE FOR FINISHED LAMPS FITTED WITH E27 CAPS FOR TESTING CONTACT-MAKING, Cód. 7006-50-1

GAUGE FOR CAPS ON FINISHED LAMPS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT DURING INSERTION E27, Cód. 7006-51A-2

GAUGE FOR CAPS ON FINISHED LAMPS FOR TESTING PROTECTION AGAINST ACCIDENTAL CONTACT E27/51X39, Cód. 7006-51-2


E26D lamp gauge
E26 lamp holder E26 lamp through regulation 7006-27D-3
 E26 lamp holder ended Regulations 7006-29L-4
 The e26d lamp prevent accidental contact with gauge 7006-29A-2
 E26 lamp holder contact with the performance of regulatory 7006-29-3
 The e26d lamp reference diameter of 23mm through regulation 7006-29B-2
 The e26d lamp reference diameter of 13.2mm pass regulations 7006-29C-2
 The e26d lamp reference diameter of 10.4mm pass regulations 7006-29D-1


E26 lamp holder gauge
E26 lamp holder through regulation 7006-27D-3
 E26 lamp holder ended Regulations 7006-29L-4
 The e26d lamp prevent accidental contact with gauge 7006-29A-2
 E26 lamp holder contact with the performance of regulatory 7006-29-3
 The e26d lamp reference diameter of 23mm through regulation 7006-29B-2
 The e26d lamp reference diameter of 13.2mm pass regulations 7006-29C-2
 The e26d lamp reference diameter of 10.4mm pass regulations 7006-29D-1
 E26 lamp holder E26 lamp through regulation 7006-27D-3
 E26 lamp holder ended Regulations 7006-29L-4
 The e26d lamp prevent accidental contact with gauge 7006-29A-2
 E26 lamp holder contact with the performance of regulatory 7006-29-3


E27 lamp holder gauge
E27 lamp holder E27 Lamp pass regulations 7006-27B-1
 E27 lamp ended Regulations 7006-28A-1
 E27S1 lamp pass regulations 7006-27C-1
 E27 lamp holder contact energy regulation 7006-50-1
 E27 lamp to prevent accidental contact with gauge 7006-51A-2
 E27 lamp holder to prevent accidental contact with gauge 51 * 397006-51-2
 E27 base torsion test gauge IEC60968Fig2

 

E39 lamp holder gauge
E39 lamp holder through regulation 7006-24B-1
 Only regulation 7006-24C-1
 Prevent accidental contact with electricity regulation 7006-24A-1


E40 lamp holder gauge
E40 through regulation 7006-25-7
 Only the regulation 7006-26-4
 Prevent accidental contact with gauge 7006-24-3
 Exposure to the performance of regulatory 7006-23-3

IEC60061 IEC60968 lamp gauge series E27|E26|E39|E40B22|B15 lamp gauge

E27 Lamp gauge

IEC60061-3 7006-27B-1  IEC60061-3 7006-28A-1
IEC60061-3 7006-50-1 IEC60061-3 7006-51-2
IEC60061-3 7006-51A-2 IEC60061-3 7006-27C-1
IEC60061-3 7006-25A-2 IEC60061-3 7006-26-4
IEC60061-3 7006-21-5 IEC60061-3 7006-22A-4
IEC60061-3 7006-22B-1 IEC60061-3 7006-22C-1
IEC60061-3 7006-22D-1 

 
E26 Lamp Gauge

IEC60061-3 7006-27D-3 IEC60061-3 7006-29L-4
IEC60061-3 7006-29A-2 IEC60061-3 7006-29-3
IEC60061-3 7006-29B-2 IEC60061-3 7006-29C-2
IEC60061-3 7006-29D-1 

 
E40 Lamp Gauge

IEC60061-3 7006-25-7
IEC60061-3 7006-26-4
IEC60061-3 7006-24-3 IEC60061-3 7006-23-3

 

E39 Lamp Gauge

IEC60061-3 7006-24B-1
 
IEC60061-3 7006-24C-1
 
IEC60061-3 7006-24A-1
 

E27 E14 E26 B22 G5 G13 Lamp Gauge , BS1363/IEC60320/UL498/AS3112 Gauges.

 


IEC60061 E14 lamp gauge

Specifications:

IEC60061-3,7006-27F-1 "Go"gauges for E14 caps on finished lamps
IEC60061-3,7006-28B-1 "Not go "gauges for E14 caps on finished lamps
IEC60061-3,7006-54-1 gauge for finished lamps fitted with E14 caps for testing contact making
IEC60061-3,7006-55-2 Gauge for finished lamps with E14 caps for testing port.
IEC60061-3,7006-27G-1 "Go" gauges for dimension "S1"of E14 caps on finished lamps
IEC60061-3,7006-25-7 E14 "Go" plug gauge for screw threads
IEC60061-3,7006-26-4 E14 "Not go" plug gauge for screw thread of lampholders
IEC60061-3,7006-30-2 E14 plug gauge for lampholders for testing contract making
IEC60061-3,7006-31-4 E14 Gauge for testing contact making and port.Against acc.Contact during insertion
IEC60061-3,7006-30A-1 E14 plug gauge for lampholders with candle shaped shaft for candle lamps for testing contract making

 

GAUGE FOR G13 LAMPS  7006-46A-3|G5 GAUGE FOR LAMPS7006-46-3|G13,G5 Lamp Gauge  
Detailed
 "GO"AND "NOT GO" GAUGE FOR UNMOUNTED BI-PIN CAP (NOT FOR USE ON FINISHED LAMPS)
 G5, Cód. 7006-46-3
 
"GO" GAUGE FOR BI-PIN CAP ON FINISHED LAMPS G5, Cód. 7006-46A-3


"GO"AND "NOT GO" GAUGE FOR UNMOUNTED BI-PIN CAP (NOT FOR USE ON FINISHED LAMPS) G5, Cód. 7006-46-3
 GO" GAUGE FOR BI-PIN CAP ON FINISHED LAMPS G5, Cód. 7006-46A-3

 


 

Payment Terms:TT
IEC60061 Go and Not go gauge 1IEC60061 Go and Not go gauge 2IEC60061 Go and Not go gauge 3IEC60061 Go and Not go gauge 4IEC60061 Go and Not go gauge 5

Member Information

Shenzhen chuangxin Instruments Co.,LTD.
Country/Region:Guang Dong - China
Business Nature:Manufacturer
Phone:13691663359
Contact:hong (sales manager )
Last Online:20 Dec, 2013

Related Products of this Company