Power cables-Rated Voltage 3.6/6~26/35kV for XLPE insulated power cable

Power cables-Rated Voltage 3.6/6~26/35kV for XLPE insulated power cable
Model:-
Brand:BAOSHIDA
Origin:Made In China
Category:Electronics & Electricity / Optical Fiber, Cable & Wire / Electric Wire & Cable
Label:BAOSHIDA , power cable , manufacturer
Price: US $60 / meter
Min. Order:1 meter
Inquire Now

Product Description

Product Name Rated Voltage 3.6/6~26/35kV for XLPE insulated power cable

For XLPE (cross-linked polythene) insulated power cable, either chemical method or physical method is employed to transform the molecular structure of PE (polythene) from chain into three-dimensional network, i.e. thermoplastic PE is transformed into thermosetting XLPE. After cross-linking, the thermal and mechanical properties of PE have been greatly improved while its excellent electrical property are still retained.
The maximum permissible operating temperature of the conductor of XLPE insulated power cable is 90℃ which resistance is higher than that of PVC (polyvinyl chloride) or PE insulated power cable. The cable has the advantage of simplicity in construction, lightness in weight, convenience in application besides its excellent electrical, thermal, mechanical and anti-chemical corrosion properties. It can also be laid with no limitation of level difference along the route.

Product Standard:
The product is manufactured according to the standard of GB/T12706-2002 “Extruded solid dielectric power cables for rated voltages from 1kV(Um=1.2kV) to 35kV (Um=40.5kV)”or IEC, BS, DIN and ICEA upon request.

Application:
The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6~26/35kV.

Operating characteristics:
Rated power-frequency voltage U0/U: 3.6/6~26/35kV
Max. Permissible continuous operating temperature of conductor: 90℃.
Max. temperature of conductor during cutting-out shall not exceed 250℃.(5S maximum duration)
The circumstance temperature under installation should not below 0℃.
The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of a three-core cable should not less than 15 times of the cable diameter.

Voltage Designation:
The rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used, and is expressed in the form of U0/U(Um)kV.
U0——The rated power-frequency voltage between conductor and earth or metallic screen, for which the cable designed;
U ——The rated power-frequency voltage between conductors, for which the cable designed;
Um——The maximum value of the “highest system voltage” for which the equipment may be used.

The values of U0 recommended for cables to be used in three-phase systems are listed below:

 

U
kV

 

Um
kV

U0* kV

System categories A and B

System categories C

6

7.2

3.6

6

10

12

6

8.7

15

17.5

8.7

12

20

24

12

18

30

36

18

35

40.5

21

26

Note: System category  A ——This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor, is disconnected from the system within 1 min;
System category  B ——This category comprises those system which, under fault conditions, are operated for a short time with one phase earthed. This period should not exceed 1h. For a longer period, not exceeding 8h on any occasion can be tolerated. The total duration of earth faults in any year should not exceed 125h.;
System category  C ——This category comprises all systems which do not fall into categories A and B.

Type and Description


Type

Description

Application

YJV

Copper conductor XLPE insulated and PVC sheathed power cable

For laying indoors, in tunnel or cable trench, unable to bear external mechanical forces. Single core cable in magnetic duct is not permissible.

YJLV

Aluminum conductor XLPE insulated and PVC sheathed power cable

YJY

Copper conductor XLPE insulated and PE sheathed power cable

YJLY

Aluminum conductor XLPE insulated and PE sheathed power cable

YJV22

Copper conductor XLPE insulated steel tape armoured and PVC sheathed power cable

For laying indoors, in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force.

 

YJLV22

Aluminum conductor XLPE insulated steel tape armoured and PVC sheathed power cable

YJV23

Copper conductor XLPE insulated steel tape armoured and PE sheathed power cable

 

YJLV23

Aluminum conductor XLPE insulated steel tape armoured and PE sheathed power cable

YJV32

Copper conductor XLPE insulated fine steel wire armoured and PVC sheathed power cable

 

For laying indoors, in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force.

 

YJLV32

Aluminum conductor XLPE insulated fine steel wire armoured and PVC sheathed power cable

YJV33

Copper conductor XLPE insulated fine steel wire armoured and PE sheathed power cable

 

YJLV33

Aluminum conductor XLPE insulated fine steel wire armoured and PE sheathed power cable

 

Production Range of Cable

 

Type

 

No. of cores

   rated voltage    kV

3.6/6

6/6
6/10

8.7/10
8.7/15

12/20

18/20
18/30

21/35

26/35

   Nom. cross-sectional area of conductor    mm²

YJV  YJLV
YJY  YJLY

1

25—800

25—800

25—800

35—800

50—630

50—630

50—630

3

25—630

25—630

25—500

35—500

50—400

50—400

50—400

YJV22  YJLV22
YJV23  YJLV23

1

25—800

25—800

25—800

35—800

50—630

50—630

50—630

3

25—630

25—630

25—500

35—500

50—400

50—400

50—400

YJV32  YJLV32
YJV33  YJLV33

1

25—800

25—800

25—800

35—800

50—630

50—630

50—630

3

25—630

25—630

25—400

35—400

50—240

50—185

50—150

Note: The single-core armoured cables are used for D.C system only, as for A.C system, non-magnetic armour material should be used or a magnetic isolation should be applied.

Main Technical Data of Cable
D.C. resistance of conductor and conductor maximum short circuit current

 

 

Nom.  cross-
sectional  area
of  conductor
mm²

Max. D.C. resistance of conductor at 20℃
Ω/km

Conductor maximum short circuit current (1S) at 90℃
kA

Copper conductor

Aluminum conductor

Copper conductor

Aluminum conductor

25

0.727

1.200

3.69

2.42

35

0.524

0.868

5.15

3.37

50

0.387

0.641

7.31

4.79

70

0.268

0.443

10.2

6.68

95

0.193

0.320

13.8

9.03

120

0.153

0.253

17.4

11.4

150

0.124

0.206

21.7

14.2

185

0.0991

0.164

26.7

17.5

240

0.0754

0.125

34.6

22.6

300

0.0601

0.100

43.1

28.2

400

0.0470

0.0778

57.4

37.6

500

0.0366

0.0605

71.7

47.0

630

0.0283

0.0469

88.8

58.0

Current carrying capacity of cable
3.6/6~12/20kV XLPE insulated power cable

 

conductor

Nom. cross- sectional area
mm²

   In the air

   Under the ground

   Single-core

Three-core

  Single-core

Three-core


○  ○

 

○○○


○  ○

 

○○○

 

 

 

Copper
Conductor

25

140

165

120

150

160

125

35

170

205

140

180

190

155

50

205

245

165

215

225

180

70

260

305

210

265

275

220

95

315

370

255

315

330

265

120

360

430

290

360

375

300

150

410

490

330

405

425

340

185

470

560

375

455

480

380

240

555

665

435

530

555

435

300

640

765

495

595

630

485

400

745

890

565

680

725

520

500

855

1030

765

825

630

980

1190

860

940

 

 

Aluminum
Conductor

25

110

130

90

115

120

100

35

135

155

110

135

145

120

50

160

190

130

160

175

140

70

200

235

165

200

215

170

95

240

290

200

240

255

210

120

280

335

225

270

290

235

150

320

380

255

305

330

260

185

365

435

295

345

370

300

240

435

515

345

400

435

345

300

500

595

390

455

490

390

400

585

695

450

520

565

440

500

680

810

595

650

630

790

950

680

745

Note: The screen-copper-tape and steel wire (including all copper wire for magnetism separation) of single-core steel wire armoured power cable for AC system must be connected to earth well and effectively. 
The current carrying capacity is calculated by formulas of IEC. It is advised in the new edition of GB/T12706 that the current carrying capacity of steel wire armored power cable with special structure is lower than that in IEC standard, so the cross-section should be enlarged appropriately.

 

18/20~26/35kV XLPE insulated power cable

 

conductor

Nom. cross- sectional area
mm²

  In the air

   Under the ground

  Single-core

Three-core

  Single-core

Three-core


○  ○

 

○○○


○  ○

 

○○○

 

 

Copper
Conductor

50

220

245

185

215

225

200

70

270

305

230

265

275

250

95

330

370

280

315

330

300

120

375

425

310

360

375

330

150

425

485

360

400

420

380

185

485

555

400

455

475

425

240

560

650

470

525

555

490

300

650

745

540

595

630

555

400

760

870

610

680

720

625

500

875

1000

775

825

630

1000

1160

875

940

 

 

Aluminum
Conductor

50

170

190

145

165

175

170

70

210

235

190

200

215

190

95

255

285

215

240

255

230

120

290

330

240

270

290

255

150

330

375

280

305

325

295

185

380

430

310

345

370

330

240

435

505

365

400

430

380

300

510

580

430

455

490

435

400

595

680

485

525

565

500

500

690

790

600

645

630

800

920

685

740

Note: The screen-copper-tape and steel wire (including all copper wire for magnetism separation) of single-core steel wire armoured power cable for AC system must be connected to earth well and effectively. The current carrying capacity is calculated by formulas of IEC. It is advised in the new edition of GB/T12706 that the current carrying capacity of steel wire armored power cable with special structure is lower than that in IEC standard, so the cross-section should be enlarged appropriately.

Installation and Operation Condition of Cable
Max. Rated temperature of the cable conductor:90℃.
Circumstance temperature in air:40℃.
Ground temperature:25℃.
Soil thermal resistivity:1.0℃.m/W.
Depth of laid:0.8m.
Single-circuit only: 
Single-core cable is installed in parallel. Adjacent space is equivalent to the diameter of the cable.

Rating factors of current carrying for different soil temperature


Soil temperature 

15

20

25

30

35

40

45

Rating factor

1.07

1.04

1.0

0.96

0.92

0.87

0.83

Rating factors of current carrying for different thermal resistivity


Rating factors for soil thermal resistivity 1.0℃.m/W

 

1.0

 

1.2

 

1.5

 

2.0

 

2.5

 

3.0

 

3.5

Three cores

1.0

0.943

0.877

0.792

0.736

0.675

0.641

Single core

1.0

0.934

0.850

0.748

0.692

0.635

0.598

Rating factors of current carrying for different air temperature


Air temperature

20

25

30

35

40

45

50

Rating factor

1.18

1.14

1.10

1.05

1.0

0.95

0.89

 

Power cables-Rated Voltage 3.6/6~26/35kV for XLPE insulated power cable 1Power cables-Rated Voltage 3.6/6~26/35kV for XLPE insulated power cable 2Power cables-Rated Voltage 3.6/6~26/35kV for XLPE insulated power cable 3Power cables-Rated Voltage 3.6/6~26/35kV for XLPE insulated power cable 4Power cables-Rated Voltage 3.6/6~26/35kV for XLPE insulated power cable 5