Coal Mine Signal Cable

 Coal Mine Signal Cable
Model:-
Brand:BAOSHIDA
Origin:Made In China
Category:Electronics & Electricity / Optical Fiber, Cable & Wire / Electric Wire & Cable
Label:mining cable , BAOSHIDA , manufacturer
Price: US $80 / meter
Min. Order:1 meter
Inquire Now

Product Description

Product Standard:
Enterprise standard

Application:
This product is suitable to work below underground coal mine with 250V AC rated voltage & 30KHz transmission frequency. 

Operating characteristics:
•Long-term service temperature of the cable conductor should not exceed 70℃.
•Cable laying temperature should not be less than 0℃ and the min. bending radius is 10 times of cable outer diameter.

Type, Description and Application:


Type

Description

Application

 

PUYVP

Mine PE insulated combustion retardant PVC sheathed signal cable

In underground electric field with relatively large disturbance

 

PUYVR

Mine PE insulated combustion retardant PVC sheathed soft signal cable

As underground common signal or end instrument information transmitting line

 

PUYVRP

Mine PE insulated copper wire screened combustion retardant PVC sheathed soft signal cable

In underground electric field with relatively large disturbance

  Cable Specifications:
 


Type

Nominal cross section
mm²

 Fabric of cores
No./Diameter 
mm

No.of cores

PUYVP

1.5

1/1.38

4

PUYVR

0.5、1.5

7/0.30、7/0.52

4

PUYVRP

0.75

7/0.37

2、3

Technical Conditions: 
1、Structure size and chief technical parameters of this product:

Type

No.of core*Nominal cross section
mm²

Insulation thickness
mm

Sheathed thickness
mm

Diameter 
mm

Weight 
kg/km

PUYVP

4*1.5

0.7

1.6

14.0

265

PUYVR

4*0.5

0.6

1.0

7.5

105

4*1.5

0.7

1.0

10.5

135

PUYVRP

2*0.75

0.6

1.0

10.5

278

3*0.75

0.6

1.0

11.0

307

 2、Conductor resistance(20℃)of cable should not be more than:
0.5mm²    37.5Ω/km;
0.75mm²   25.1Ω/km;
1.5mm²    12.5Ω/km。
3、Cable should undergo AC 50Hz 1000V voltage test for 1min, without being punctured.
4、 Work capacity of cable should be ≤ 0.061μF/km..
5、Cable inductance should not be bigger than 0.716mH/km.