JUNXY Series Resistive & Reactive AC Load Banks
It is really critical that your standby power system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc working in good condition if switched to be loaded when the main power supply in maintenance procedure or stop abnormally. Downtime could be reduced by regular maintenance and thorough inspections which are the key to power supply systems maintenance. Critical power backup equipment like UPS System and generator which especially located in harsh, dusty or corrosive environment will fail without proper preventative maintenance. So validating the condition and output of such power systems must be conducted comprehensively. JUNXY provides a whole range of custom preventative maintenance products solutions for UPS systems and generators and many more to ensure constant uptime for your power systems and make you prepared for anything.
JUNXY resistive & reactive AC load banks are used to simulate the motor loads or other electromagnetic devices working at their rated power factor. For different testing purposes and applications, JUNXY mainly manufactures three kinds of resistive & reactive AC load banks: RL AC load bank, RLC AC load bank & RCD AC load bank.
JUNXY Series Resistive & Inductive AC Load Banks
JUNXY resistive & inductive AC load banks are used to simulate the motor loads or other electromagnetic devices working at their rated power factor. Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability.
Technical Specifications |
|||||||||||
Models |
AC230V-6kW-RL |
AC480V-30kW-RL |
AC480V-60kW-RL |
AC480V-100kW-RL |
AC480V-200kW-RL |
AC480V-500kW-RL |
|||||
Capacity |
Resistive load:
|
Resistive load:
|
Resistive load:
|
Resistive load:
|
Resistive load:
|
Resistive load:
|
|||||
Customized solutions could be available upon request. |
|||||||||||
Rated Voltage |
Single Phase, AC230V |
Three Phase AC480V, or units can be specified by customer |
|||||||||
Customized solutions could be available upon request. |
|||||||||||
Rated current
|
Resistive amperes per phase: 26A
|
Resistive amperes per phase: 36A
|
Resistive amperes per phase: 72A
|
Resistive amperes per phase: 120A
|
Resistive amperes per phase: 240A
|
Resistive amperes per phase: 601A
|
|||||
PF |
PF=0.8(or customized power factor) |
||||||||||
Minimum Load Step |
100W, 100VAR |
100W, 100VAR |
100W, 100VAR |
1kW, 1kVAR |
1kW, 1kVAR |
1kW, 1kVAR |
|||||
Customized solutions could be available upon request. |
|||||||||||
Display |
Voltage, Current, Frequency, Power and PF displayed by digital meter |
||||||||||
Protection |
Overheating alarm, Short circuit protection, Overheating protection, Fan overloading protection, Emergency stop button. All protections can be configured optionally |
||||||||||
Control Mode |
Manual control by MCBs or push buttons |
||||||||||
Air Flow |
Horizontal, Force-air cooling |
||||||||||
Dimension |
51*50*110(cm) |
90*90*160(cm) |
90*90*200(cm) |
120*120*200(cm) |
90*90*200(cm) |
120*120*200(cm) |
|||||
Options |
Handle panel or PC remote control selectable |
JUNXY Series Resistive, Inductive & Capacitive AC Load Banks
JUNXY RLC load banks are mostly used for inverter anti-islanding test experiments which meets the PV & grid inverter testing requirements for islanding prevention detection, work efficiency test, overload protection test, over-current protection test, power factor test, grid current harmonic test, resonance point test, and so on. Both Leading power factor (Capacitive) and lagging power factor (Inductive) could be available with JUNXY series RLC AC load banks.
Technical Specifications |
|||
Model |
JUNXY-AC480V-30kW-RLC |
JUNXY-AC480V-60kW-RLC |
JUNXY-AC480V-100kW-RLC |
Capacity |
Resistive load: 30kW
|
Resistive load: 60kW
|
Resistive load: 100kW
|
or units can be specified by customer |
|||
Rated Voltage |
Rated voltage Three Phase 480VAC, or units can be specified by customer |
||
Frequency |
50Hz and 60Hz are available |
||
PF |
0.1-1.0 |
||
Min. load step |
100W, 100VAR |
1kW, 1kVAR |
1kW, 1kVAR |
or units can be specified by customer |
JUNXY Series Resistive, Capacitive & Diode AC Load Banks
JUNXY series RCD load banks are similar to a reactive load bank in rating and purpose, except that leading power factor loads are created. JUNXY RCD AC load banks are used to simulate the no-linear or electronic loads typically for the industires: telecommunication, computer, UPS, generator & invertor. To test the real load capacity & crest factor.
JUNXY series RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.
Development of digitization and networking with today's society, Rectifier loads such as computers, network equipment is widely used. These load with nonlinear characteristics of rectifier-filter circuits, its value is not constant, power output range, stability is even more demanding. UPS power supply, inverter power supply for network devices, you must use the simulated load is nonlinear, to debug parameters such as its crest factor test.
But traditional RLC simulated load based on linear load, unable to change characteristics of nonlinear load simulation, also makes it difficult to test the UPS power supply, inverter power supply, such as in a data center, network tension power performance in your environment. Only RCD nonlinear loads, power supply output power and power quality make the most accurate judgment.
Technical Specifications |
|||||||||
Models |
AC240V-10kW-RCD |
AC415V-30kW-RCD |
AC415V-60kW-RCD |
AC415V-100kW-RCD |
AC415V-250kW-RCD |
AC415V-400kW-RCD |
|||
Rated Capacity |
Resistive: 10kW
|
Resistive: 30kW
|
Resistive: 60kW
|
Resistive: 100kW
|
Resistive: 250kW
|
Resistive: 400kW
|
|||
Customized solutions could be available upon request. |
|||||||||
Rated Voltage |
Single Phase AC240V |
Three phase AC415V, or units can be designated by customer |
|||||||
Customized solutions could be available upon request. |
|||||||||
Maximum current |
96A |
1P: 96A
|
1P: 192A
|
1P: 319A
|
1P: 798A
|
1P: 1278A
|
|||
Frequency |
50/60 Hz |
||||||||
PF |
PF=0.6-1.0 |
||||||||
Minimum Load Step |
100W, 100VAR |
100W, 100VAR |
100W, 100VAR |
1kW, 1kVAR |
1kW, 1kVAR |
1kW, 1kVAR |
|||
Customized solutions could be available upon request. |
|||||||||
Display |
Voltage, Current, Frequency, Power and PF displayed by digital meter |
||||||||
Protection |
Overheating alarm, Short circuit protection, Overheating protection, Fan overloading protection, Emergency stop button. All protections can be configured optionally |
||||||||
Control Mode |
Manual control by MCBs or push buttons |
||||||||
Air Flow |
Horizontal, Force-air cooling |
||||||||
Dimension |
51*63*120(cm) |
51*97*120(cm) |
80*140*185(cm) |
80*140*185(cm) |
80*150*155(cm) |
80*150*190(cm) |
Payment Terms: | TT |
---|---|
JUNXY (HK) ENERGY CO., LTD | |
---|---|
Country/Region: | Guang Dong - China |
Business Nature: | Manufacturer |
Phone: | 13510680184 |
Contact: | Jack Xie (sales manager) |
Last Online: | 09 Aug, 2016 |