JUNXY Series Rack Mounted Load Banks
It is really critical that your standby power system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc working in good condition if switched to be loaded when the main power supply in maintenance procedure or stop abnormally. Downtime could be reduced by regular maintenance and thorough inspections which are the key to power supply systems maintenance. Critical power backup equipment like UPS System and generator which especially located in harsh, dusty or corrosive environment will fail without proper preventative maintenance. So validating the condition and output of such power systems must be conducted comprehensively. JUNXY provides a whole range of custom preventative maintenance products solutions for UPS systems and generators and many more to ensure constant uptime for your power systems and make you prepared for anything.
Following on from construction and testing, Data Centre Commissioning is essential to ensure that the completed facility is configured for maximum efficiency. Missing out the essential Data Centre Commissioning can lead to an inefficient facility and higher than expected operational costs. By simply identifying where equipment manufacturers’ standard specifications are not appropriate for the IT load, the supporting infrastructure, in particular the cooling plant, can be configured to meet the requirements of the facility and lead to much higher levels of efficiency. Data centre commissioning can lead to significant energy savings when implemented correctly by a specialist commissioning team. By engaging JUNXY power solutions to ensure that systems are running correctly, clients have saved up to 67% on facility operational costs.
The Junxy rack mounted AC & DC load banks are designed especially for internet data center (IDC) test and commissioning. Load bank integrated system test (IST) could precisely simulate the data center’s electricity consumption, heat dissipation, air flow, hot & cold aisle testing, thus to ensure the effective operation of power supply & distribution system (generator, UPS, EPS included), air conditioning system, lightning protection and earthing system, monitoring system, data center integrated environments, cabinet IT environment, providing independent verification of integrated system testing. Successful IST(integrated system test) should have installation of server load banks in data center and server room etc, Junxy provides resistive, reactive and capacitive load banks in low or medium voltage to cover the entire scope of your commission and testing requirements.
Applications
Ø Data center & server room cooling system test
Ø Data center air flow, hot/cold aisle environment inspection
Ø Validating the tire level of data center
Ø Validating the reliability of data center power supply & distribution system
Ø Testing the main network before connecting user devices (servers, switches, etc.)
Technical Specifications |
||||||||
Models |
AC120V-3KW |
AC230V-3KW |
AC230V-6KW |
AC230V-10.5KW |
DC270V-3KW |
DC270V-6KW |
||
Capacity |
3KW |
3KW |
6KW |
10.5KW |
3KW |
6KW |
||
Customized solutions could be available upon request. |
||||||||
Rated Voltage |
AC120V |
AC230V |
DC270VDC |
|||||
Customized solutions could be available upon request. |
||||||||
Minimum Load Step |
250W |
250W |
500W |
500W |
100W |
100W |
||
Customized solutions could be available upon request. |
||||||||
Air Quantity |
480CFM |
480CFM |
680CFM |
1040CFM |
680CFM |
880CFM |
||
Dimension |
3U |
4U |
6U |
9U |
4U |
4U |
||
19’’ Standard Rack |
||||||||
Options |
Air flow control and display, digital meter, remote control |
|||||||
Cables |
C13 C14 |
Note:
Ø Remote control function is optional
Ø AC & DC load voltage could be made compatible in ONLY one unit with several different load voltages.
Ø In some countries, 220V 1P will be replaced by 120V/230V/240V/277V 1P, 380V 3P will be replaced by 208V/400V/415V/480V 3P.
Ø Resistive AC load bank for load voltage 208V 3P and 120V 1P, 415V 3P and 240V 1P, 480V 3P and 277V 1P with higher load power are also available as per your need.