WALKER MEDICAL VACUUM

WALKER MEDICAL VACUUM
Model:A038MV,A058MV
Brand:WALKER
Origin:-
Category:Industrial Supplies / Machinery / Filters
Label:Walker , medical vacuum , A058MV
Price: US $412 / pc
Min. Order:1 pc
Inquire Now
点击这里给我发消息

Product Description

WALKER medical vacuum sterilizing filter

The alpha series medical vacuum sterilizing filter is specially designed to protect the equipment from liquids, solid particles and bacterial contamination.

The diameter of the interface is from 1/4 inch to 3 inch, and the screw shell is made of cast aluminum alloy material, and Walker e-coat technology is used for anti-corrosion treatment.Intelligent, modular design ensures optimal flow, ease of installation and multiple coupling characteristics.DN80 - DN150 flanges are welded by carbon steel and have polyester protective coatings.

The design is intelligent, unique and modular

The intelligent filter core design is prefiltered by the hydrophobic borosilicate medium and the open reticular foam.Through unique material structure, energy efficiency is improved, and reliable filtration is realized to minimize pressure drop.

Custom filter medium for optimum efficiency

The unique drop-fit filter has the function of preventing shock, improving stability and improving drainage.Designed for en286-1 and compatible with PED (97/23 / EC) and SPVD (87/404 / EEC).

More than the standard of UK health technology memos 02-01 (HT M 02-01)

Application range includes: hospital dentistry;Internal medicine;Veterinarians, medical devices, etc

The technical specification

MODEL

PIPE SIZE

FLOW RATE

DIMENSIONS(mm

WEIGHT

Kg

ELEMENT 

MODEL

ELEMENT NO.

(Nm3/h)

(SCFM)

A

B

C

D

A028MV

Rp1/4

3.5

2.1

70

25

191

85

0.6

E0406MV

1

A038MV

Rp3/8

5

2.9

70

25

191

95

0.6

E0407MV

1

A058MV

Rp1/2

7

4.1

70

25

232

135

0.7

E0413MV

1

A059MV

Rp1/2

12

7.1

100

35

276

155

1.6

E0613MV

1

A078MV

Rp3/4

15

8.8

100

35

276

155

1.6

E0613MV

1

A079MV

Rp3/4

25

14.7

100

35

396

225

2.0

E0620MV

1

A108MV

Rp1

33

19.4

100

35

396

225

2.0

E0620MV

1

A109MV

Rp1

45

26.5

100

35

396

275

2.0

E0625MV

1

A128MV

Rp11/4

60

35.3

122

42

460

320

2.8

E0730MV

1

A158MV

Rp11/2

70

41.2

122

42

460

320

2.8

E0730MV

1

A159MV

Rp11/2

95

55.9

146

52

482

325

4.2

E0830MV

1

A208MV

Rp2

120

70.6

146

52

482

325

4.2

E0830MV

1

A209MV

Rp2

175

103

146

52

785

630

6.3

E0860MV

1

A254MV

Rp21/2

190

112

210

66

595

410

8.5

E1140MV

1

A340MV

Rp3

200

118

210

66

595

410

8.5

E1140MV

1

A360MV

Rp3

225

132

210

66

815

630

10.5

E1160MV

1

A390MV

Rp3

265

156

210

66

975

785

12

E1175MV

1

A391MV

DN80

330

194

450

265

1205

n/a

58

E139MV

1

A483MV

DN100

406

238

520

285

1245

n/a

74

E88MV

3

A484MV

DN100

492

289

520

285

1245

n/a

74

E88MV

4

A686MV

DN150

660

388

680

400

1400

n/a

165

E88MV

6

 

 

 

* at atmospheric pressure (1 bar) and 20 ℃ environment

 

Filter class

 

The MV

 

Particle removal efficiency

 

> 99.995%

 

The highest temperature

 

60 ℃

 

140 ° F

 

Pressure loss - clean and dry

 

30 millibars

 

44 pounds per inch

 

Pressure loss - replace the filter element

 

100 millibars

 

1.5 pounds per inch

 

Maximum working pressure

 

0.5 millibars

 

7 pounds per inch (see note 5)

 

Maximum working vacuum

 

All of the vacuum

 

Color of cartridge cover

 

black

 

 

 

 

 

* according to the specification of the gas piping system of htm02-01, it is consistent with BS 3928-1969

Technical note

1. The air flow direction is through the filter element from the outside.

2. Mechanical indicator (65dpuga-250) matching model A028MV to A058MV as the standard.The differential pressure gauge (65DPG250G) matched the model A059MV to A390MV as the standard.The differential gauge applies to all flange connection models.

3. Manual drain valve (MDV25) applies to all models.The sterilized glass exhaust water bottle is standard, and 100 ml is suitable for the model A028MV to A078MV, which is suitable for the model A079MV to A390MV. The additional 1/2 inch feeding side drain is included in the model A391MV to A686MV.

4. The flow above is the free air flow under one bar.

5. The pressure of the side leakage test must be limited to 7 millibar, and only the drain valve and drain valve have been removed.

6. Threads and double helix filters are made of cast aluminum alloy and are compatible with flammable gases with standard PED 97/23 / EC.

7. If supply is available in North America, the corresponding standard iso7/1 of thread connection is called Rp (BSP parallelism), or corresponding to ANSI B2.1 is the NPT.Flange connector is fully matched with BS4504, PN16.

8. Add suffix N to NPT connector.For example: A038MVN.

9. Flange filters are cast in carbon steel.

The flanges are designed and cast in standard BS EN286 and meet the simple pressure vessel requirements.

11. Tolerance error of cross port dimensions of flanged vessels is controlled within the range of plus or minus 3mm, and the vertical error is 1 degree.

12, every 6 months or 1000 hours, the filter cartridge should be replaced (subject to the deadline).

 

WALKER MEDICAL VACUUM 1WALKER MEDICAL VACUUM 2WALKER MEDICAL VACUUM 3WALKER MEDICAL VACUUM 4

Member Information

shenzhen pomea science & technology co., ltd.
Country/Region:Guang Dong - China
Business Nature:Trading Company
Phone:13825286405
Contact:Raymond Song (Manager)
Last Online:24 Apr, 2022