Model: | PAB-060 |
---|---|
Brand: | ESDMAN |
Origin: | Made In China |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | PAB-060 , ESDMAN , Ionization |
Price: |
US $540
/ pc
|
Min. Order: | 1 pc |
Safety:
1. Do not disassemble the product without permission.
2. Do not use in dangerous environment ( such as flammable and explosive )
3. Do not use in place with plenty of oil or water, high temperature and humidity, especially in places with condensation.
4. S estion: temperature 5-40°C; humidity 20-75%RH ( no condensation of water droplets ).
5. The ionizing air bar can eliminate static electricity without wind, or use clean compressed gas or N2
6. When the power is on, it is strictly prohibited to touch the discharge emitter.
7. Do not operate with wet hands, otherwise it may cause electric shock or malfunction.
8. Do not put fingers, iron wires, tools and other metal objects near the discharge emitter.
9. Please check the power supply specifications before connecting the power supply, and use the supplied power supply.
10. The attached power transformer is dedicated for PAB series ionizing air bar, please do not use it for other purposes.
11. A gas pipe ( outer diameter 8mm ) with proper pressure resistance must be used.
12. Because ozone ( less than 0.05ppm ) is generated during the operation of the equipment, please do not use it in a confined space.
Industry Standard and System Certificate:
1. This product has passed the ISO 9001:2015 standard certification ( certificate code:18ACM6508Q )
2. This product has passed CE / EN 55014-2:2015 & EN 61326-1; 2013 ) standard certification
3. This product has passed FCC ( FCC PART15 SUBPART B:2017 ) standard certification
4. Comply with the limit requirements of ANSI/ESD S20.20 for audit inspection and conformity verification test of ionization equipment
5. Comply with ANSI/ESD STM 3.1 requirements for audit inspection and testing of ionization equipment
6. Meet the requirements of ANSI/ESD SP 3.3 for air ionization equipment to conduct regular compliance verification tests
7. Comply with the limit requirements of IEC 61340-5-1 for audit inspection and conformity verification test of ionization equipment
8. Comply with the limit requirements of JESD 625-B on the verification test of ionization equipment
9. Comply with the requirements of GJB3007A-2009 on the verification test of ionization equipment.
10. The product meets ISO14644-1 Class4 cleanliness requirements
Product Description:
PAB pulse AC ionizing air bar adopts DC high voltage power supply, and applies voltage to the discharge emitter through alternating positive and negative DC high voltage coupling. Ionize air molecules to produce a large number of positive and negative air ions, which are transmitted to the surface of charged objects through compressed gas. It neutralizes the positive and negative electrostatic charges on the surface of the object, and the strong compressed air flow can also blow away the dust or particles on the surface of the charged object. It neutralizes the positive and negative electrostatic charges on the surface of the object, and the strong compressed air flow can also blow away the dust or particles on the surface of the charged object, so as to achieve the effect of removing static electricity and dust.
1. PAB pulse AC ionizing air bar is a bar-shaped, horizontal static eliminator
2. The output ratio of positive and negative ions can be adjusted separately to adjust the ion balance
3. The output frequency of positive and negative ions is adjustable, and the speed of eliminating static electricity can be adjusted for different places of use
4. Installation distance and working frequency setting reference
Feature:
1. Pulsed AC Ionizing technology
2. Two ion nozzles are available, 4-hole type and 2-hole small flow type
3. Ion nozzle can be changed quickly
4. The cleaning cycle can be set freely between 50H-9999H
5. Discharge needles are available in a variety of materials, tungsten, titanium, silicon
6. Optional networking type
7. Optional pressurized air wand type A
8. CE FCC certification
Benefits:
1. Can eliminate static electricity in a large area without wind
2. 4-hole type large flow dust removal effect is better
3. Easy to maintain, clean and replace
4. When the cleaning cycle is up, the yellow light will turn on and the buzzer will sound the alarm
5. Discharge emitter of different materials can be selected according to the environment
6. Wireless control
7. PC software monitors multiple air bars
8. Ion emitter can be added to effectively accelerate the speed of static elimination
9. With electromagnetic protection function, it will not interfere with other equipment
Instructions:
When the ambient humidity is high, the residual voltage may shift, and it is best to use it at a humidity of about 50%RH
a. Air source conection: Connect the clean and dry compressed air pipe to the 8mm air pipe interface
b. Air flow regulation: Equipped with SMC throttle valve, which can be rotated left and right to lock the air flow of
appropriate size.
c. Connect power supply: Insert the DC24V power output plug into the LINK IN port of the ion wind wand; Connect the AC100-240V plug to the indoor power outlet
d. Turn on the device: Press the POWER button to turn on; RUN/H.V indicator light is green The equipment is normal. e. Device address: Connect the software, set the device address on the PC, or you can inform the device address
number when purchasing, set it at the factory and label it
f. Cleaning cycle: After power on, the screen displays E000, which is the cumulative working time. Press the increment button to enter the cleaning cycle reminder setting. The screen displays H000, continue to press the increment button to increase in units of 50 hours. If the preset is 500 hours, press the increment button continuously, the screen will display as H500, and the device will automatically save as 500 hours and alarm. After 3 seconds, it will automatically exit the setting mode, display E000 ( accumulated working time ) , and the factory defaults for a cleaning cycle of 500 hours
g. Working frequency: After power on, the screen displays E000, which is the accumulated working time. Press the SET
button, the screen displays the frequency between F.01-F.80. Press the increment or decrement keys to adjust to the appropriate frequency ( F.01 is 1Hz / F.80 is 80Hz ). Please refer to the product introduction to select the appropriate working frequency and installation distance
h. Ion Balance: After the frequency adjustment is completed, if it is set to F.30, that is, the working frequency is set to 30Hz, press the SET button again, and the screen displays Hxx. For example, H60 represents the positive ion output ratio is 60%. At this time, press the increment button or decrement Press the button to increase or decrease the positive ion output ratio, increase the positive ion ratio and decrease the negative ion ratio at the same time, otherwise reduce the
positive ion ratio and increase the negative ion ratio at the same time. Through the residual voltage displayed on the CPM, increase or decrease the ion output ratio adjustment Ion balance, adjust the residual voltage to less than plus or minus 30V, press the SET button to exit the adjustment mode, when the screen displays Exxx, the cumulative working time is displayed, and the balance setting mode is exited.
Installation method:
Please pay attention to the installation of PAB series pulse AC ionizing air bar
1. Make sure that the ionizing bars are arranged in four directions, left and right, front and rear, with a distance of at least 10CM from the wall
2. Keep a minimum distance of 40CM between two adjacent static elimination bars
3. If there is a metal ground or conductor near the installation location of the static elimination bar, keep a minimum distance of 20cm
4. If the air outlets of the two iozning air bars are installed correspondingly, keep a minimum distance of 20CM
5. When installing the ionizing air bars with a length of 156/180/204/228/252/300 cm, an auxiliary bracket must be installed to prevent the bar from bending
6. A single ionizing air bar carries a 1.8-meter-long power supply and power cord
7. If you use the network, you can choose the appropriate length of the network cable according to the installation distance
Installation:
1. Install brackets on both sides of the ionizing air bar, and fix the brackets on both sides of the bar with M5 screws
2. The mounting bracket is reserved with multiple mounting holes. Use M4 screws to fix the ionizing air bar at the position that needs to be installed.
Daily maintenance:
Please pay attention when cleaning the discharge emitter
1. Please be sure to unplug the PAB power supply to prevent personnel from touching the high voltage.
2. After long-term use of the PAB air rod, the discharge emitter will become dirty due to the accumulation of dust, which will cause the reduction of static electricity elimination ability. Please clean the discharge needle tip regularly.
3. Rotate and remove the ion nozzle from the bar body, rotate it to the left to remove it, clean the discharge emitter tip with a cotton swab dipped in alcohol, after cleaning, rotate it to the right to install the ion nozzle.
Abnormal alarm:
1. Cleaning alarm: When the CHECK red LED light is on, the discharge emitter needs to be turned off and cleaned. After the cleaning is completed, turn it on and the CHECK red light is off
2. H.V alaram: When the ALARM red LED light is on, it means the high voltage is abnormal, and the ionizing air bar eliminates the static electricity abnomrally. Please check if there is any conductive object in contact with the discharge needle.
ESDMAN CO.,LTD | |
---|---|
Country/Region: | Guang Dong - China |
Business Nature: | Trading Company |
Phone: | 15818753657 |
Contact: | Phoenix Hu (Sales) |
Last Online: | 20 Jul, 2022 |