Wireless photoelectric smoke fire detection alarm (hereinafter referred to as "smoke detector") is a device that detects fire by sensing smoke. When smoke is generated and reaches a certain concentration, the device will send out an audible and visual alarm signal, and meanwhile send a wireless signal to the main gateway, prompt you to take corresponding measures on-site and remotely, effectively protect you and your family safety of life and property.

 

2. Tecnical Parameters

Alarm Classification: Fire alarm, Low battery alarm, Fault alarm, Testing alarm

Alarm Mode: audible and visual alarm

Alarm Volume: >85dB(A) at 3 meters
Indicator: smoke alarm, low voltage, malfunction

Dimension: 96*96*45 mm

Weight: 136g

Mounting Position: ceilling

Power Supply: DC3V

Operating Current: ≦80MA

Quiescent Current: ≦6uA

Battery Lifetime: 10 years (Disposable Battery CR123)

Operating Temperature: -10℃ to +55℃

Relative Humidity: ≦90%

Radio Frequency: 433.92MHZ
FM Mode: ASK

Transmit Power: 10db

Radio Distance: ≦120m (open distance)

Implementation Standards: GB 20517-2006

 

 

1. Fire Alarm Function

(1) Smoke Detected

The smoke detector will send out audible and visual alarm prompts immediately after it detects smoke, and meanwhile sends wireless alarm messages to the main gateway.

Note: There is no limit on the number of alarm messages sent within 12 hours after the smoke detector is powered on. It will enter the cost-saving mode after 12 hours of power on.

( If the alarm message exceeds ten times in an hour, it will be limited to ten minutes before sending a wireless signal. When the alarm does not occur for 24 consecutive hours, it can return to normal. )

(2) If a fire occurs, take appropriate measures in a timely manner, such as calling 119, using fire extinguishing equipment, etc.

(3) If there is no fire, you can press the mute/self-test button to mute the alarm (the mute time is about 12 hours, during which there is no sound prompt), you can long press the mute/self-test button for more than 3 seconds to cancel the mute function.

(4) Note: The following situations may trigger a fire alarm

a. Sprayed insecticides, make-up, etc. emit a mist that comes into direct contact with smoke detector.

b. Smoke from burning materials such as cigarettes and incense comes into contact with the smoke detector.

c. Smoke-type, gradually heated evaporative insecticide sprays mist that comes into contact with smoke detector.

d. Cooking fumes or steam, etc. coming into contact with the smoke detector.

e. Alarm condensation

 

2. Fault Alarm Function

(1) Automatically test whether the function is normal

If the smoke cannot be detected normally (in case of malfunction), please contact the dealer for inspection or repair as soon as possible. The smoke detector will not detect smoke and will not sound a fire alarm in the event of a fault. Note: There is no wireless signal prompt for fault alarm.

(2) Fault silence

a. When the smoke sensor detects a malfunction, the indicator light will flash yellow three times continuously every 50 seconds or so, and the buzzer will beep three times continuously at the same time, please contact the maintenance personnel for inspection and repair as soon as possible.

b. When a fault alarm occurs, pressing the Mute/Self-Test button will silence the fault alarm for approximately 45 days.

c. When the fault alarm is silenced, long press the Silence/Self-test button for more than 3 seconds to release the silencing function.

 

3. Low battery Alarm Function

(1) When the battery is low, the indicator light will flash in yellow every 50 seconds or so, and the buzzer will beep once, please replace the battery as soon as possible; after the low battery alarm, a wireless signal reminder will be sent every 2 hours.

(2) When a low battery alarm occurs, pressing the silence/self-test button will silence the low battery alarm for approximately 45 days.

(3) When the low battery alarm is silenced, long press the mute/self-test button for more than 3 seconds to release the silencing function.

 

4. Tamper Alarm Function

Press and hold the tamper switch for about 10 seconds and then release it. The smoke detector will send out an tamper alarm message (the wireless signal is the same as the smoke alarm), and without buzzer sound prompt.

Note: Only a maximum of 24 tamper alarm messages are allowed to be sent per day.

 

5. Heartbeat Function

(1) The smoke detector will send heartbeat data to the main gateway every 2 hours. The main gateway uses this signal to prompt offline or online.

(2) When the smoke detector is low voltage, the heartbeat data sent becomes low voltage data.

 

6. Alarm Test Function

(1) Press and hold the Mute/Self Test button for about 3 seconds and the buzzer sounds. (Wireless signal is the same as smoke alarm).

Note: Only a maximum of 24 alarm test messages are allowed to be sent per day

(2) When the Mute/Self-Test button is released, the buzzer stops beeping and the smoke detector exits the simulated alarm state.

Note: When the battery power is low or the smoke detector fails or the smoke alarm occurs, the alarm test function is disabled, press and hold for 3 seconds to release the silencer function.

 

7. Self-test Function

(1) Press and hold (about one second) the mute/self-test button to perform self-test.

Serial Number

Indicate Status

Buzzer Status

Normal working status

Red and green flash alternately once

Beep once

Low battery alarm silence state

Yellow flashes once

Beep once

Fault alarm silence state

Yellow flashes three times

Beep three times

Fire alarm silence status

Red flashes three times

Beep three times

(2) When the smoke detector is normal, the green light will flash once every 50 seconds. If not, please check whether the battery is exhausted or the device is malfunctioning.

Note: Perform self-test on the smoke detector (recommended monthly). If any fault is found, please repair it in time.