Over Load Protection |
115~140% of rate load. Protection type : Constant current limiting, recovers automatically after fau |
OVER VOLTAGE |
Protection type : Shunt down o/p voltage, re-power on to recover. |
OVER TEMPERATURE |
TSW1: 95?C (Detect on the heatsink of PFC MOSFET) TSW2: 90?C (Detect the winding of output choke) |
|
Protection type : Shun down o/p voltage, recovers automatically after temperature goes down |
REMOTE CONTROL |
RC+/RC-: 0 ~ 0.8V=power on ; 4 ~ 10V=power off sink current <20mA |
WORKING TEMP., HUMIDITY |
-10~+65?C (Refer to output load derating curve), 20~90% RH non-condensing |
STORAGE TEMP., HUMIDITY |
20~+85?C , 10~95% RH |
TEMP. COEFFICIENT |
?0.03%/?C (0~50?C) |
VIBRATION |
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY STANDARDS |
UL1950, TUV EN60950 Approved |
EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
HARMONIC CURRENT |
Compliance to EN61000-3-2,-3, Class A |
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A |
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
MTBF |
59.6K hrs min. MIL-HDBK-217F (25 ?C) |
Input Voltage |
90 ~ 264VAC 127 ~ 370VDC |
Input Frequency |
47 ~ 63Hz |
Power Factor |
0.95/230VAC 0.95/115VAC at full load |
AC Current |
11.2A/115AVC 5.6A/230VAC |
Inrush Current |
32A/115VAC 63A/230VAC |
Leakage Current |
<2mA / 240VAC |
Setup, Rise Time |
1500mS, 50mS/230VAC 1500mS, 50mS/115VAC at full load |
Hold Time |
24mS/230VAC 24mS/115VAC at full load |