MAIN SPECIFICATIONS OF GENERATOR SETS |
GENSET MODEL |
C20 |
C30 |
C45 |
C68 |
C77 |
C91 |
C104 |
Continuous output (KW/KVA) |
20 / 25 |
30 / 37.5 |
45 / 56 |
68 / 85 |
77 / 96 |
91 / 114 |
104 / 130 |
Standby output (KW/KVA) |
22 / 27.5 |
33 / 41.25 |
50 / 63 |
75 / 94 |
85 / 106 |
100 / 125 |
114 / 143 |
TECHNICAL DATA |
DIESEL ENGINE MODEL |
4B3.9-G2 |
4BT3.9-G2 |
4BTA3.9-G2 |
6BT5.9-G2 |
6BT5.9-G2 |
6BTA5.9-G2 |
6BTAA5.9-G2 |
Engine Characters |
Water-cooled, in line, 4-stroke, direct injection, Wet cylinder liner, 1500rpm (at 50Hz)/1800 rpm (at 60Hz) |
Constant output (KW) |
24 |
36 |
50 |
92 |
92 |
110 |
120 |
Standby output (KW) |
27 |
40 |
55 |
100 |
100 |
120 |
132 |
Aspiration |
Natural |
Turbo charged |
Turbo&Aftercooled |
Turbo charged |
Turbo charged |
Turbo&Aftercooled |
Turbo&Aftercooled |
Bore(mm)×Stroke(mm) |
102×120 |
102×120 |
102×120 |
102×120 |
102×120 |
102×120 |
102×120 |
Cubic Capacity(Liters) |
3.91 |
3.91 |
3.91 |
5.9 |
5.9 |
5.9 |
5.9 |
Piston Speed(m/s) |
|
|
|
|
|
|
|
Compression Ratio |
16.5:1 |
16.5:1 |
16.5:1 |
17.5:1 |
17.5:1 |
17.5:1 |
17.5:1 |
Cooling System Volume(L) |
8 |
8 |
8 |
11 |
11 |
31 |
17 |
Max. Water Temperature |
100℃ |
100℃ |
100℃ |
100℃ |
100℃ |
100℃ |
100℃ |
Speed characteristics |
The speed stability bandwidth ≤+0.25%. The steady governing rate ≤1% |
Fuel Consumption |
≤215g/kW.h |
≤215g/kW.h |
≤215g/kW.h |
≤215g/kW.h |
≤215g/kW.h |
≤220g/kW.h |
≤220g/kW.h |
Lube Consumption (prime) |
≤1.36g/kW.h |
≤1.36g/kW.h |
≤1.36g/kW.h |
≤1.36g/kW.h |
≤1.36g/kW.h |
≤1.36g/kW.h |
≤1.36g/kW.h |
Fan Cooling Air Flow(m³/ h) |
6790 |
6790 |
6790 |
7470 |
7470 |
7470 |
7470 |
Intake Air Flow(I/s) |
52 |
52 |
52 |
94 |
94 |
N/A |
N/A |
Exhaust Gas Flow(m³/ h) |
572 |
601 |
612 |
840 |
1020 |
1302 |
1352 |
Exhaust Temperature(℃) |
480 |
492 |
502 |
510 |
576 |
524 |
541 |
Exhaust Back Pressure |
10kPa(Maximum) |
10kPa(Maximum) |
10kPa(Maximum) |
10kPa(Maximum) |
10kPa(Maximum) |
10kPa(Maximum) |
10kPa(Maximum) |
ALTERNATOR MODEL |
With Stamford, Leroy Somer, Marathon or other branded alternators etc. |
Continuous Output (KW/KVA) |
22 / 27.5 |
30 / 37.5 |
48 / 60 |
68 / 85 |
80 / 100 |
91 / 114 |
112 / 140 |
Power Efficiency |
81% |
90% |
88.6% |
90.2% |
90.4% |
90.8% |
91.7% |
Voltage Regulation |
±1.0% with 4% engine governing |
|
|
Waveform Distortion |
No lode ≤1.5% and non-disttorting balanced linear load ≤5% |
|
|
THF / TIF |
<2% / <50 |
<2% / <50 |
<2% / <50 |
<2% / <50 |
<2% / <50 |
<2% / <50 |
<2% / <50 |
Fan Cooling Air Flow(I/s) |
216 |
216 |
216 |
514 |
514 |
514 |
514 |
dimensions (L×W×H) (mm) |
1610×650×1340 |
1610×650×1340 |
1630×650×1460 |
2070×750×1460 |
2190×750×1460 |
2330×750×1460 |
2330×750×1460 |
Net Weight (kg) |
950 |
1050 |
1110 |
1370 |
1400 |
1500 |
1500 |