Model: | APV-5000W |
---|---|
Brand: | EYEN |
Origin: | Made In China |
Category: | Computers & AV Digital / Computer Accessories / UPS Power Supply |
Label: | solar inverter , inverter charger , power inverter |
Price: |
-
|
Min. Order: | 20 pc |
Last Online:23 Jun, 2017 |
Electrical Specvifications | ||||||||
Model | APV 1000W | APV 1500W | APV 2000W | APV 3000W | APV 4000W | APV 5000W | APV 6000W | |
Output (Inverter mode) | Continuous Output Power | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W |
Surge Rating | 3000W | 4500W | 6000W | 9000W | 12000W | 15000W | 18000W | |
Output Waveform | Pure Sine wave/Same as input(Bypass mode) | |||||||
Nominal Efficiency | >88%(Peak) | |||||||
Line Mode Efficiency | >95% | |||||||
Power Factor | 0.9-1.0 | |||||||
Nominal Output Voltage rms | 100-110-120Vac / 220-230-240Vac | |||||||
Output Voltage Regulation | ±10% RMS | |||||||
Output Frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | |||||||
Short Circuit Protection | Yes( 1sec after fault ) | |||||||
Typical Line Stansfer Time | 10ms(MAX) | |||||||
THD | <10% | |||||||
DC Input | Nominal Input Voltage | 12.0Vdc | ||||||
( *2 for 24Vdc, *4 for 48Vdc) | ||||||||
Minimum Start Voltage | 10.0Vdc | |||||||
Low Battery Alarm | 10.5Vdc / 11.0Vdc | |||||||
Low Battery Trip | 10.0Vdc / 10.5Vdc | |||||||
High Voltage Alarm | 16.0Vdc | |||||||
Low Battery voltage recover | 15.5Vdc | |||||||
Idle Consumption-Search Mode | < 25 W when Power Saver On | |||||||
AC Charger | Input Voltage Range | Wide: 90~135VAC / 164~243VAC;
Narraw: 100~135VAC / 194~243VAC; |
||||||
Output Voltage | Depends on battery type | |||||||
Max Charge Rate | 35A / 70-90A Max (Charger Current Control) | |||||||
Battery Initial Voltage for Start Up | Circuit breaker | |||||||
Over Charge Protection Shutdown | 15.7V for 12V( *2 for 24Vdc, *4 for 48Vdc) | |||||||
Charger curve(4 stage constant current)
4 step digital controlled progressive charge |
Battery types ( *2 for 24Vdc, *4 for 48Vdc) | |||||||
Battery type | Fast V Float V( *2 for 24Vdc, *4 for 48Vdc) | |||||||
Gel U.S.A | 14.0 | 13.7 | ||||||
A.G.M 1 | 14.1 | 13.4 | ||||||
A.G.M 2 | 14.6 | 13.7 | ||||||
Sealed Lead Acid | 14.4 | 13.6 | ||||||
Gel Euro | 14.4 | 13.8 | ||||||
Open Lead Acid | 14.8 | 13.3 | ||||||
Calcium | 15.1 | 13.6 | ||||||
De-sulphation | 15.5 for 4hrs | |||||||
Remote Control | Yes. Optional | |||||||
Bypass & Protection | Input Voltage Waveform | Sine wave (Grid or Generator) | ||||||
Nominal Voltage | 120VAC / 230VAC | |||||||
Low Voltage Trip | 90V±4%/184V/154V±4% | |||||||
Low Voltage re engage | 100V±4%/194V/164V±4% | |||||||
High Voltage Trip | 140V±4%/ 253V±4% | |||||||
High Voltage re engage | 135V±4%/243V±4% | |||||||
Max Input AC Voltage | 150VAC/270VAC | |||||||
Nominal Input Frequency | 50Hz or 60Hz (Auto detect) | |||||||
Low freq trip | 47Hz± 0.3Hz for 50Hz, 57Hz± 0.3Hz for 60Hz | |||||||
Low freq re engage | 48Hz± 0.3Hz for 50Hz, 58Hz± 0.3Hz for 60Hz | |||||||
High freq trip | 55Hz± 0.3Hz for 50Hz, 65Hz± 0.3Hz for 60Hz | |||||||
High freq re engage | 54Hz± 0.3Hz for 50Hz, 64Hz± 0.3Hz for 60Hz | |||||||
Overload protection | Circuit breaker | |||||||
Short circuit protection | Circuit breaker | |||||||
Transfer switch rating | 30amp | 40amp | ||||||
Max bypass current | 30amp | 40amp | ||||||
Bypass over load current | 35amp: Alarm | 45amp: Alarm | ||||||
Solar Charger | Rated Voltage | 12V/24V/48V | ||||||
Rated Charge Current | 40A/60A | |||||||
Rated Output Current | 15A | |||||||
Self Consumption | < 10mA | |||||||
Bulk Charge | 14.5V(default) | ( *2 for 24Vdc, *4 for 48Vdc) | ||||||
Floating Charge | 13.5V(default) | |||||||
Equalization Charge | 14.0V(default) | |||||||
Over Charge Disconnection | 14.8V | |||||||
Over Charge Recovery | 13.6V | |||||||
Over Discharge Disconnection | 10.8 V(default) | |||||||
Over Discharge Reconnection | 12.3V | |||||||
Temperature Compensation | - 13.2mV/℃ | |||||||
Ambient Temperature | 0-40℃(full load) 40-60℃(derating) | |||||||
Mechanical Specifications | Mounting | Wall mount | ||||||
Inverter Dimensions(L*W*H) | 598*218*179mm | 470*190*340mm | ||||||
Inverter Weight | 21KG | 22kg | 23KG | 27KG | 38KG | 48KG | 48KG | |
Shipping Dimensions(L*W*H) | 740*315*300mm | 530*240*390mm | ||||||
Shipping Weight | 23KG | 24kg | 25KG | 29KG | 40KG | 50KG | 50KG | |
Display | Status LEDs / Status LEDs+LCD | |||||||
Standard Warranty | 1 Year |
Payment Terms: | TT/LC/Western Union |
---|---|