Model: | KVV/KVVP/KVVP2/ |
---|---|
Brand: | YITENG |
Origin: | Made In China |
Category: | Electronics & Electricity / Optical Fiber, Cable & Wire / Other Wire & Cable |
Label: | control cable , sheathed cable , pvc insulated cable |
Price: |
US $0.75
/ meter
|
Min. Order: | 500 meter |
Last Online:01 Mar, 2017 |
PVC Sheathed Flexible Control Cable XLPE Insulated Copper Conductor Braiding Shielded Cable
Specifications
Copper Conductor, XLPE Insulated, Braiding Shielded, PVC Sheathed Flexible Control Cable
GB9330-1988,IEC,DIN,BS,450/750V AC
Control Cable 450/750V Copper Coductor PVC Insulated and sheathed Flexible Control Cable
Detailed Product Description
1.Standard
The control cable can be produced according to the standard GB9330-1988,IEC,DIN,BS,and the factory can also manufacture the cables in accordance with other standards.
2.Scope of Application
The control cable are suitable for the wiring of electrical controlling equipments and instrument,monitoring and controlling return circuit,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.
3.PVC sheath control cable
1)Max. Rated Temperature Of The Conductor Is 90oc
2)Max. Short-Circuit Temperature Of The Conductor Shall Not Exceed 250oc
3)Max. Sustaining Period Not Ecxeed 5 Seconds.
4)Installation Temperature Of Cable Shall Not Below 0oc .
5)Recommended Permissible Bending Radius:
A)For Non-Armormed Cable,Shall Not Be Less Than 6 Times Of The Cable's Overall Diameter.
B)For Armored Or Copper Tape Shielded Cable,Shall Not Be Less Than 12 Times Of The Cable's Overall Diameter.
C)For Soft Cable With Shield Layer,Shall Not Be Less Than 6 Times Of The Cable's Overall Diameter.
6)Used as power and connecting cables in mechanical engineering for tooling machinery, control unit, production lines, transportation equipment, conveyor and assembly lines as well as in plant construction under the circumstance that the rated voltage is up to 450/750V AC.
4.Character and Relevant Parameters
1. Long-term service temperature of the cable conductor: 70 0C
2. Rated voltage: 450/750V
3. Cable lying temperature ≥ 0 0C
4. Cores: 2, 3, 4, 5, 6, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37, 44, 48, 52, 61
5. Minimun bending radius:
Non armored ≥ Out diameter of cable 6 times
Armored layer or copper tape shielded ≥ Outer diameter of cable 12 times
Shielded layer soft cable ≥ Outer diameter of cable 6 times
PVC Insulated Control Cable Parameter (Example)
5.Type Name Section Area(mm2) No. Of Core
KVV Copper Conductor, PVC Insulated and Sheathed control cable 0.75 1.0 1.5 2.5 2-8 10 12 14 16 19 24 27 30 37
4.0 6.0 2-8 10 12 14
KVVP Copper Conductor, PVC Insulated and Sheathed, Copper-braid Screened Control Cable 0.75 1.0 1.5 2.5 2-8 10 12 14 16 19 24 27 30 37
4.0 6.0 2-8 10 12 14
KVVP2 Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable 0.75 1.0 1.5 2.5 2-8 10 12 14 16 19 24 27 30 37
4.0 6.0 2-8 10 12 14
KVVP2-22 Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Steel-tape armored Control Cable 0.75 1.0 1.5 2.5 2-8 10 12 14 16 19 24 27 30 37
4.0 6.0 2-8 10 12 14
KVV22 Copper Conductor, PVC Insulated and Sheathed, Steel-tape armored Control Cable 0.75 1.0 1.5 2.5 2-8 10 12 14 16 19 24 27 30 37
4.0 6.0 2-8 10 12 14
KVVR Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable 0.75 1.0 1.5 2.5 2-8 10 12 14 16 19 24 27 30 37
4.0 6.0 2-8 10 12 14
KVVRP Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable 0.75 1.0 1.5 2.5 2-8 10 12 14 16 19 24 27 30 37
4.0 6.0 2-8 10 12 14
6.Type& Specification
Type |
Name |
Section Area(mm2) |
No. of Core |
Application Site |
KVV |
Copper Conductor,PVC Insulated and Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-16 |
Permanent installation indoors,in cable ditches or pipes |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KVVP |
Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded Control Cable |
0.75 1.0 1.5 2.5 |
2-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KVVP2 |
Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable |
0.75 1.0 1.5 2.5 |
4-10 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
7-61 |
|||
10 |
4-10 |
|||
KVV22 |
Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force |
4 6 |
4-14 |
|||
10 |
4-14 |
|||
KVVR |
Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable |
0.5-2.5 |
4-61 |
Installation indoors where flexibility and movability are required |
KVVRP |
Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable |
0.5 0.75 1.0 |
4-61 |
Installation indoors where flexibility shielding and movability are required |
1.5 2.5 |
4-48 |
|||
KYJV |
Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-16 |
Permanent installation indoors,in cable ditches or pipes |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KYJVP |
Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
2-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
2-14 |
|||
10 |
2-10 |
|||
KYJV22 |
Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force |
4 6 |
4-14 |
|||
10 |
4-10 |
|||
KYJVP2 |
Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 |
7-61 |
Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 |
4-14 |
|||
10 |
4-10 |
|||
KYJVR |
Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable |
0.5-2.5 |
4-61 |
Installation indoors where flexibility and movability are required |
KYJVRP |
Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable |
0.5 0.75 1.0 |
4-61 |
Installation indoors where flexibility shielding and movability are required |
1.5 2.5 |
4-48 |
7.Service Conditions
(1) The long-time working temperature of conductor of PVC insulated cable is 70oC
The long-time working temperature of conductor of XLPE insulated cable is 90oC
(2) The temperature for laying the cables cannot be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D
Why choose Us
1. Fast delivery
2. Sample available .
3.Top cable supplier in China
4. ISO, IEC,CE ,CCC certifications.
5. Honest Manufacturer.
6.Advanced customization
7.Strong technical support
8.Strict quality control system
9. Quality guarantee after delivery
Our Test Instrument
FAQ:
1.Q: Is your company a manufacturer or a trade company?
A: We are cable manufacturer.
2. Q: Where is your factory located? How can I visit there?
A:Our factory is located in Ningjin City, Hebei Province, China. You can fly to Shijiazhuang airport directly. All our clients, from home or abroad, are warmly welcome to visit us!
3. Q: What is your sample policy?
A: Some of our samples are available for free, while others are available at a cost, which will be deducted from the purchase order.
4.Q: How does your factory do regarding quality control?
A: Quality is priority. We always attach great importance to quality controlling from the very beginning to the very end.
5. Q: I am very interested in your product, can you sent me your full catalog and pricing list?
A: We can select some popular products for you immediately. Please let us know your requirements so that we can send out the quotation to you.
Our Services
1. We guarantee to offer new advanced goods.
2. We'd like to send skilled personnel to the installing place to help offer technical consultant, quantity estimation and instruction, installing, preliminary testing,and help start up running; and to answer for any defect of the product found in installing and run testing,If there's something wrong with the product, we'll give our answer within 12 hours and get to the spot within 36 hours.
3.After installaton, We'll send skilled personnel to have the preliminary test and answer for any problems emerged. We take the whole charge of the fee needed in repairing,testing or retesting within the scope of our duty required in contract.
4.During the contract's period of validity,of the project must be started all over again or the goods can not be used at all which is resulted from
our faulty goods and improper files or mistakes made by our instructors, we'll change the goods at once without compensation and take charge in all expenses of reinstallation.
Notice:we can produce the product according to customer's requirment.Short delivery time and quotation at once.