CU Conductor XLPE Insulated PVC Sheathed Power Cable
1.The applications: Rated voltage (U0/U) 0.6/1kv 8.7/15KV 26/35kV in transmission & transformation line & for water-proofing purpose .
2. Cores: 1~5 cores,3C+1E,4C+1E,3C+2E
3.Standards: 60502IEC ISO9001
4. Product features:
1) No necessary to heat up in advance while installing above 0oC.
2) Max. continuous normal operating Temperature: 90oC (PVC Sheathed cable).
3) Max. Permissible temperature at short circuit (5s. at longest): 250oC.
4) Permissible bending radius:
Single core: ≥20(d+D)±5%.
Three-core:≥15(d+D)±5%(D is the actual overall diameter of cable, and d is the actual overall diameter of conductor).
Detailed Description
Cross-linked polyethylene insulated power cable not only has excellent electric and mechanical properties, but also has powerful resistance against chemical corrosion, heat-aging and environmental stress. Its structure is simple and using conveniently, also can be laid with no restriction of different level. The long term operating temperature is 90, and its transmit capacitance is large.
Our company can produce both flame retardant and non-flame retardant series of XLPE power cable.. Our products can be produced according to our works specifications which are equivalent to GB12706, IEC60502, IEC60332, IEC60754, and its some indexes are superior to standards stated above..
The flame-retardant cable covers all kinds of low-smoke low-halogen, low-smoke halogen free and three classes of A, B, C. We can design and manufacture special XLPE cable according to the other standards require by the customers, such as heavy section cut part conductors, water-resistant, defend termites, defend mouse, and so on.
Model and Data
U0/Um(kv) |
1st class |
0.6/1kv |
1.8/3kv |
3.6/6kv |
6/10kv |
8.7/15kv |
12/20kv |
18/30kv |
21/35kv |
No.of Core |
|||||||||
1 Core |
Section |
1.5-800 |
25-800 |
25-800 |
25-800 |
35-800 |
50-800 |
50-800 |
50-800 |
|
|||||||||
area(mm2) |
|||||||||
2 Core |
Section |
1.5-185 |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
|
|||||||||
Area(mm2) |
|||||||||
3 Core |
1.5-400 |
25-400 |
25-400 |
25-400 |
35-400 |
50-400 |
50-400 |
50-400 |
|
4 Core |
Section |
2.5-400 |
25-400 |
/ |
/ |
/ |
/ |
/ |
/ |
Area(mm2) |
Four cores:
cross section mm2 |
insulated thickness mm |
sheath thickness mm |
outer diameter mm |
testing voltage kv |
current loading capacity |
|
in the air |
to be laid underground |
|||||
1.5 |
0.7 |
1.5 |
10.6 |
3.5 |
21 |
25 |
2.5 |
0.7 |
1.5 |
11.5 |
3.5 |
28 |
33 |
4 |
0.7 |
1.5 |
12.8 |
3.5 |
37 |
44 |
6 |
0.7 |
1.5 |
14 |
3.5 |
46 |
54 |
10 |
0.7 |
1.5 |
15.9 |
3.5 |
63 |
73 |
16 |
0.7 |
2 |
19.1 |
3.5 |
84 |
94 |
25 |
0.9 |
2 |
22.7 |
3.5 |
109 |
120 |
35 |
0.9 |
2 |
25.4 |
3.5 |
132 |
144 |
50 |
1 |
2 |
29 |
3.5 |
159 |
169 |
70 |
1.1 |
2 |
32.9 |
3.5 |
195 |
205 |
95 |
1.1 |
2.5 |
37.7 |
3.5 |
237 |
245 |
120 |
1.2 |
2.5 |
41.6 |
3.5 |
273 |
278 |
150 |
1.4 |
3 |
47.6 |
3.5 |
310 |
309 |
185 |
1.6 |
3 |
50.6 |
3.5 |
355 |
347 |
240 |
1.7 |
3 |
56.4 |
3.5 |
416 |
399 |
300 |
1.8 |
3.5 |
62.2 |
3.5 |
473 |
446 |
400 |
2 |
3.5 |
68.9 |
3.5 |
512 |
431 |
3+1 cores:
cross section mm2 |
insulated thickness mm |
sheath thickness mm |
outer diameter mm |
testing voltage kv |
current loading capacity |
|
in the air |
to be laid underground |
|||||
1.5 |
0.7 |
1.5 |
10.6 |
3.5 |
21 |
25 |
2.5 |
0.7 |
1.5 |
11.5 |
3.5 |
28 |
33 |
4 |
0.7 |
1.5 |
12.5 |
3.5 |
37 |
44 |
6 |
0.7 |
1.5 |
13.7 |
3.5 |
46 |
54 |
10 |
0.7 |
1.5 |
15.4 |
3.5 |
63 |
73 |
16 |
0.7 |
2 |
17.5 |
3.5 |
84 |
94 |
25 |
0.9 |
2 |
21.8 |
3.5 |
109 |
120 |
35 |
0.9 |
2 |
23.8 |
3.5 |
132 |
144 |
50 |
1 |
2 |
27.4 |
3.5 |
159 |
169 |
70 |
1.1 |
2 |
31 |
3.5 |
195 |
205 |
95 |
1.1 |
2.5 |
34.8 |
3.5 |
237 |
245 |
120 |
1.2 |
2.5 |
39.7 |
3.5 |
273 |
278 |
150 |
1.4 |
3 |
42.9 |
3.5 |
310 |
309 |
185 |
1.6 |
3 |
52.7 |
3.5 |
355 |
347 |
240 |
1.7 |
3 |
58 |
3.5 |
416 |
399 |
300 |
1.8 |
3.5 |
62.2 |
3.5 |
473 |
446 |
400 |
2 |
3.5 |
68.9 |
3.5 |
512 |
431 |
YJV Type
Model |
Name
|
Uses |
Cores |
Conductor nominal cross section mm2
|
YJV |
Copper core XLPE insulated PVC sheathed power cable
|
Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull. YJY YJLY
|
1 |
1.5~800
|
YJY
|
Copper core XLPE insulated PVC sheathed power cable
|
Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull. YJY YJLY
|
2 |
1.5~800
|
YJV22
|
Copper core XLPE insulated PVC sheathed power cable
|
Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull. YJY YJLY . |
3 |
1.5~400
|
YJLV23 |
Copper core XLPE insulated PVC sheathed |
Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull. YJY YJLY
|
4 |
1.5~400
|
YJV32
|
Copper core XLPE insulated PVC sheathed power cable
|
Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull. YJY YJLY
|
3+1 |
1.5~400
|
YJV33
|
Copper core XLPE insulated PVC sheathed power cable
|
Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull. YJY YJLY
|
4+1 |
+ 1.5~400
|
ZR Type
Type |
Description |
Main Application |
|
Cu core |
Al core |
||
(ZR)YJV |
(ZR)YJLV |
(Flame retardant) Cu, Al core XLPE insulated, PVC or PE sheathed power cable. |
For laying indoor, tunnel, underground and canal. Unable to bear external mechanical pulling force and pressure during laid. |
(ZR)YJV22 |
(ZR)YJLV22 |
(Flame retardant) Cu, Al core XLPE insulated, steel armoured, PVC or PE sheathed power cable. |
For laying indoor, tunnel, underground and canal. Able to bear external mechanical pulling force , but unable to bear large pulling force. |
(ZR)YJY23 |
(ZR)YJLV23 |
||
(ZR)YJLV32 |
(ZR)YJLV32 |
(Flame retardant) Cu, Al core XLPE insulated, fine steel wire armoured, PVC or PE sheathed power cable |
For laying in shaft, water under ground and large difference of level, able to bear mechanical pressure and moderate pulling force. |
(ZR)YJLV42 |
(ZR)YJLV42 |
(Flame retardant) Cu, Al core XLPE insulated, thick steel wire armored, PVC or PE sheathed power cable |
For laying in the water, seabed and large difference of level, able to bear large mechanical pressure and pulling force. |
or |
or |
||
(ZR)YJLV43 |
(ZR)YJLV43 |
FAQ:
1.Q: Is your company a manufacturer or a trade company?
A: We are cable manufacturer.
2. Q: Where is your factory located? How can I visit there?
A:Our factory is located in Ningjin City, Hebei Province, China. You can fly to Shijiazhuang airport directly. All our clients, from home or abroad, are warmly welcome to visit us!
3. Q: What is your sample policy?
A: Some of our samples are available for free, while others are available at a cost, which will be deducted from the purchase order.
4.Q: How does your factory do regarding quality control?
A: Quality is priority. We always attach great importance to quality controlling from the very beginning to the very end.
5. Q: I am very interested in your product, can you sent me your full catalog and pricing list?
A: We can select some popular products for you immediately. Please let us know your requirements so that we can send out the quotation to you.
Our Services
1. We guarantee to offer new advanced goods.
2. We'd like to send skilled personnel to the installing place to help offer technical consultant, quantity estimation and instruction,
installing, preliminary testing,and help start up running; and to answer for any defect of the product found in installing and run testing,
If there's something wrong with the product, we'll give our answer within 12 hours and get to the spot within 36 hours.
3.After installaton, We'll send skilled personnel to have the preliminary test and answer for any problems emerged. We take the whole charge of the fee needed in repairing,testing or retesting within the scope of our duty required in contract.
4.During the contract's period of validity,of the project must be started all over again or the goods can not be used at all which is resulted from
our faulty goods and improper files or mistakes made by our instructors, we'll change the goods at once without compensation and
take charge in all expenses of reinstallation.