Model: | DGA/DGD/DGT |
---|---|
Brand: | SUNCENTER |
Origin: | Made In China |
Category: | Industrial Supplies / Industrial Supplies Stocks |
Label: | nitrogen booster pum , gas booster , pneumatic pressure b |
Price: |
US $1000
/ pc
|
Min. Order: | 1 pc |
Last Online:05 Jun, 2018 |
Product Details
Compressed Air Driven Gas Booster Pump- DGA/DGD/DGT Series
Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:
·Compressed Air driven - no electricity required (connect to normal air compressor)
·In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar
·No airline lubricator required
·Hydrocarbon free - separation between air and gas sections
·Pressures to 80Mpa (11,600 psi)
·Wide range of models with different ratios
·Built-in-cooling on most models
·Easy to install, operate and maintain
·Best price / performance ratio
·No heat, flame or spark risk and explosion proof
·Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter pump will automatically start, keep the loop pressure constant
·Applicable gas: Argon/Helium/Hydrogen/Oxygen/NO2/CH4/LNG/LPG/CNG/FM200 etc.
Applications for Air Driven Gas Boosters
SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.
Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.
As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.
SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.
Applications
·Pressure test with gas
·Gas transfer and filling
(Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/LNG/LPG/CNG/FM200 etc.)
·Charging of gas cylinder and accumulator with nitrogen
·Supply for isolating gas systems
·Gas assisted injection molding
·Transfer of oxygen cylinders
·Charging of breathing air bottles
·Leak test
·Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components
·Safety valve adjusting
DGA series gas booster pumps(Single acting, single air drive head):
DGA pumps are available with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel.
Technical spcification
Model |
Pressure boost ratio |
Min. gas Inlet pressure
|
Max.gas
pressure
|
Max. gas
PB (bar) |
Driven air pressure PL |
Formula to
|
Connection:
|
Max. flow at driven air pressure of 6bar (L/min) |
DGA02 |
2:1 |
1.0 |
16 |
16 |
3-8 bar |
2X PL |
1/2 / 1/2 |
960 (at PA of 6 bar ) |
DGA05 |
5:1 |
1.5 |
40 |
40 |
3-8 bar |
5XPL |
1/2 / 1/2 |
680(at PA of 6 bar ) |
DGA06 |
6:1 |
2.0 |
48 |
48 |
3-8 bar |
6XPL |
1/2 / 1/2 |
360(at PA of 10 bar ) |
DGA10 |
10:1 |
3.5 |
80 |
80 |
3-8 bar |
10XPL |
3/8/ 3/8 |
210(at PA of 10 bar ) |
DGA25 |
25:1 |
7.0 |
200 |
200 |
3-8 bar |
25XPL |
1/4/ 1/4 |
120(at PA of 20 bar ) |
DGA40 |
40:1 |
10 |
320 |
320 |
3-8 bar |
40XPL |
1/4/ 1/4 |
200(at PA of 40 bar ) |
DGA60 |
60:1 |
20 |
480 |
480 |
3-8 bar |
60XPL |
1/4/ 1/4 |
180(at PA of 40 bar ) |
DGA100 |
100:1 |
25 |
800 |
800 |
3-8 bar |
100XPL |
1/4/ M14X1.5 |
136(at PA of 40 bar ) |
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
DGD series gas booster pumps(Double acting ):
DGD series pumps are double acting, single stage with double air driven heads type.
·DGD pumps are available with high quality seals, which provide significantly better service life
·Double pump heads with exhaust cooling devices.
·All components in contact with the gas are made of stainless steel.
·Pipes mounting way are available as customized.
Technical specification
Model |
Pressure boost ratio |
Min. gas Inlet pressure
|
Max.gas
pressure
|
Max. gas
PB (bar) |
Driven air pressure PL |
Formula to
|
Connection:
|
Max. flow at driven air pressure of 6bar (L/min) |
DGD10 |
10:1 |
3.5 |
80 |
80 |
3-8 bar |
10XPL+ PA |
3/8/3/8 |
410(at PA of 6 bar ) |
DGD25 |
25:1 |
10 |
200 |
200 |
3-8 bar |
25XPL+ PA |
1/4/1/4 |
396(at PA of 20 bar ) |
DGD40 |
40:1 |
15 |
320 |
320 |
3-8 bar |
40XPL+ PA |
1/4/1/4 |
320(at PA of 40 bar ) |
DGD60 |
60:1 |
25 |
480 |
480 |
3-8 bar |
60XPL+ PA |
1/4/1/4 |
215(at PA of 40 bar ) |
DGD100 |
100:1 |
35 |
800 |
800 |
3-8 bar |
100XPL+ PA |
1/4/M14*1.5 |
300(at PA of 60 bar ) |
DGD130 |
130:1 |
50 |
1040 |
1040 |
3-8 bar |
130XPL+ PA |
1/4/M14*1.5 |
180(at PA of 60 bar ) |
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 ba
DGT series gas booster pumps(Double acting, double stage, single air drive head ):
DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.
·DGT pumps are available with high quality seals, which provide significantly better service life
·Double pump heads with exhaust cooling devices.
·All parts in contact with the gas are made of stainless steel.
Technical specification
Model |
Pressure boost ratio |
Min. gas
pressure
|
Max.gas
pressure
|
Max. gas
PB (bar) |
Driven air pressure PL |
Formula to
|
Connection:
|
Max. flow at driven air pressure of 6bar (L/min) |
DGT25 |
25:1 |
1 |
10 |
200 |
3-8 bar |
25XPL+3.5XPA |
3/8/ 1/4 |
136(at PA of 8 bar ) |
DGT40 |
40:1 |
1 |
10 |
320 |
3-8 bar |
40XPL+ 6XPA |
3/8/ 1/4 |
124(at PA of 8 bar ) |
DGT10/60 |
10:1/60:1 |
1 |
10 |
480 |
3-8 bar |
60XPL+6X PA |
3/8/ 1/4 |
84(at PA of 8 bar ) |
DGT25/60 |
25:1/60:1 |
10 |
25 |
480 |
3-8 bar |
60XPL+2.5XPA |
3/8/ 1/4 |
80(at PA of 15 bar ) |
DGT100 |
100:1 |
1 |
10 |
800 |
3-8 bar |
100XPL+10XPA |
3/8/ M14*1.5 |
63(at PA of 8 bar ) |
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
Should the gas booster pumps caters to your requirement, welcome to buy the equipment with our factory. Well-known as one of the professional manufacturers and suppliers, we're equipped with a productive factory to produce the best quality equipment for you.