Model: | AQU225*2360-PVD |
---|---|
Brand: | Aqucell |
Origin: | Made In China |
Category: | Industrial Supplies / Machinery / Filters |
Label: | ultrafiltration memb , Aqucell , UF |
Price: |
¥7000
/ pc
|
Min. Order: | 1 pc |
Last Online:23 Aug, 2021 |
AQU225 × 1860-w-pvc-100kh (UPVC) technical parameters
Membrane material Modified PVC
Internal and external diameter of fiber 0.9mm/1.6mm
Molecular weight of membrane wire cutting 100K
Effective outer membrane area 63.1m2
Wire loading 9000 PCs
Pure water flux 8873L/H (0.1Mpa,25℃)
Component design water yield 6~56L/ m2.h
Shell material UPVC
End sealing material epoxy resin
Water inlet and outlet interface DN40
Service conditions
Pretreatment 50-100um
Operation mode External pressure operation
working pressure 0.02-0.2Mpa
Maximum inlet pressure 0.3MPa
Maximum membrane pressure difference 0.2MPa
Influent pH value 2-12
Continuous residual chlorine concentration is tolerable 100 ppm
Intermittent residual chlorine concentration is tolerable 200 ppm
Service temperature 5℃-45℃
Produced water quality
*Turbidity of produced water < 0.2NTU
*Pollution density index (SDI) < one
Particles (> 0.2 µ m) 100% removal
Microorganisms and pathogens 99.99% removal
Backwashing design
Backwashing frequency Once every 20-60 minutes
Backwashing pressure ≤0.2MPa
Backwash flow 150-200L/ H.m2
Backwashing dosing agent 5-15ppm sodium hypochlorite
Maintenance cleaning (CEB chemical enhanced backwashing)
Sodium hypochlorite reagent 200 ~ 500ppm sodium hypochlorite (it can be adjusted according to the specific water quality)
Acid maintenance Lotion 0.2% hydrochloric acid (it can be adjusted according to the specific water quality)
Alkali maintenance Lotion 0.05% NaOH (it can be adjusted according to the specific water quality)
Chemical cleaning design
Chemical cleaning flow 80L/ m2 .h
Chemical cleaning frequency Every 1-4 months
Pickling agent 2% citric acid, 2% oxalic acid or 0.5% hydrochloric acid (prepared into a solution with pH = 2)
Alkali washing agent 0.5% NaOH + 100 ~ 1000ppmnaclo (prepared into a solution with pH = 12)
Note: * refers to raw water test with turbidity of 15ntu under test conditions of 25 ℃ and 0.1MPa.
Payment Terms: | Corporate transfer |
---|---|