Model: | MS8217A |
---|---|
Brand: | HY |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument |
Label: | digital multimeters , DC/AC meters , MS 8217A multimeter |
Price: |
US $22.8
/ pc
|
Min. Order: | 1 pc |
MS8217A digital AC/DC multimeters
LCD display,,Keypad,Data hold,Diode,Continuity,Insulation test,
auto power off,max value measuring&hold,
DC/AC&resistance& Frequency& Temperature¤cy& Duty Cycle&capacity measuring,
Details
Environment conditions:
1000V CAT. II and 600V CAT. III
Pollution degree: 2
Altitude < 2000m
Operating temperature: 0~40℃, 32℉~122℉(<80% RH, <10℃non-condensing)
Storage temperature: -10~60 ℃, 14℉~140℉(<70% RH, battery removed)
Temperature Coefficient: 0.1´(specified accuracy) / ℃(<18℃or >28℃)
MAX. Voltage between terminals and earth ground: 1000V AC rms or 1000V DC.
Fuse Protection: mA and mA: F 500mA/250V Æ5´20; A: F 10A/250V Æ6.3´32.
Sample Rate: 3 times/sec for digital data.
Display: 3 3/4 digits LCD display. Automatic indication of functions and symbols.
Range selection: automatic and manual.
Over Range indication: LCD will display "OL".
Low battery indication: The " " is displayed when the battery is under the proper operation range.
Polarity indication: "-" displayed automatically.
Power source: 4.5V
Batterytype: AAA 1.5V.
Dimensions: 185(L)´87(W)´53(H) mm.
Weight: 360g. Approx. (battery included).
Voltage
Function |
Range |
Resolution |
Accuracy |
Input Impedance (Nominal) |
Common Mode Rejection Ratio |
Normal Mode Rejection Ratio |
DC Millivolt. mV |
400mV |
0.1mV |
±(1.0% of rdg +10 digits) |
>10MW<100pF |
>100dB at dc, 50 or 60 Hz |
>45dB at 50 or 60Hz |
DC Voltage V |
4V |
1mV |
±(0.5% of rdg +3 digits) |
|||
40V |
10mV |
|||||
400V |
100mV |
|||||
1000V |
1V |
|||||
AC Voltage1,2 V~ |
400mV3 |
0.1mV |
±(3.0% of rdg + 3 digits) |
>5MW<100pF |
>60dB at dc, 50 or 60 Hz |
_ |
4V |
1mV |
±(1.0% of rdg + 3 digits) |
||||
40V |
10mV |
|||||
400V |
100mV |
|||||
1000V |
1V |
|||||
Overload Protection: 1000V dc or 1000V ac rms. |
1. Frequency Range: 40Hz~500Hz
2. Response: Average, calibrated in rms of sine wave
3. Manual Range only
Frequency
Function |
Range |
Resolution |
Accuracy |
Frequency Hz (10Hz-100kHz) |
50.00Hz |
0.01 Hz |
±(0.1% of rdg+3digits) |
500.0Hz |
0.1 Hz |
||
5.000kHz |
0.001kHz |
||
50kHz |
0.01kHz |
||
100kHz |
0.1kHz |
||
Overload protection: 1000V dc or 1000V ac rms. |
Resistance
Function |
Range |
Resolution |
Accuracy |
Resistance W |
400.0W |
0.1W |
±(0.5% of rdg+3 digits) |
4.000kW |
1W |
±(0.5% of rdg+2 digits) |
|
40.00kW |
10W |
||
400.0kW |
100W |
||
4.000MW |
1kW |
||
40.00MW |
10kW |
±(1.5% of rdg+3 digits) |
|
Overload protection: 1000V dc or 1000V ac rms. |
Diode Test
Function |
Range |
Resolution |
Test Condition |
Accuracy |
Diode Test
|
1 V |
0.001V |
Forward DC current approximately 1mA. Reversed DC voltage approximately 1.5V. |
1.0% uncertainty |
Overload protection: 1000V dc or 1000V ac rms. |
Continuity Check
Function |
Range |
Resolution |
Description |
Test Condition |
|
400W |
0.1W |
Continuity beeper≤75W |
Open circuit voltage: approx. 0.5V |
Overload protection: 1000V dc or 1000V ac rms. |
Currency
Function |
Range |
Resolution |
Accuracy |
DC Current mA |
400mA |
0.1mA |
±(1.5% of rdg+3 digits) |
4000mA |
1mA |
||
DC Current mA |
40mA |
0.01mA |
±(1.5% of rdg+3 digits) |
400mA |
0.1mA |
||
DC Current A |
4A |
1mA |
±(1.5% of rdg+3 digits) |
10A |
10mA |
||
AC Current1,2 mA ~ |
400mA |
0.1mA |
±(1.5% of rdg+3 digits) |
4000mA |
1mA |
||
AC Current1,2 mA ~ |
40mA |
0.01mA |
±(1.5% of rdg+3 digits) |
400mA |
0.1mA |
||
AC Current1,2 A ~ |
4A |
1mA |
±(1.5% of rdg+3 digits) |
10A |
10mA |
||
Overload protection: F 10A/250V fuse for A range. F 500mA/250V fuse for mA and mA ranges. Maximum input current: 400mA dc or 400mA ac rms for mA and mA ranges, 10A dc or 10A ac rms for A ranges. For measurements>5A, 4 minutes maximum ON to measure 10 minutes OFF; Above 10A unspecified. |
1. Frequency Range: 40Hz-200Hz
2. Response: Average, calibrated in rms of sine wave
Accessories:
User's manual, Test leads, Carry case, "K" type bead Thermocouple, Multi function socket
Remind:
Do not operate the meter around explosive gas, vapor, or dust.
Do not measure voltages above 600V in Category III, or 1000V in Category II installations.
Warranty: One Year.
Any quality problem occurs whitin 7 days after you receive the goods,you can ask for replacement or refund as long as it is not damaged by personal mistake.
Shippment&Payment:
We usually shipped by air,such as DHL,UPS,FedEx,China post mail,EMS,TNT and etc as you like,shipping day is about 4 days or more depends on your order quantity, and the delivery day is about 20-40 days by EMS and post mail,by others it is within 20 days. We usually write gift on the packing with a low value to help you reduce the tax,however different countries have different rules, if you refuse to pay the tax at your country,the goods will be returned to us,you have to bear the loss.
As to payment, you can pay by T/T and western union as you like, we will ship the goods only after we get your full payment.
Shenzhen Huayi Technology Co. Ltd | |
---|---|
Country/Region: | Guang Dong - China |
Business Nature: | Manufacturer |
Phone: | 13872175283 |
Contact: | Alina Lee (Sales Manager) |
Last Online: | 28 Dec, 2015 |