Model: | H302 |
---|---|
Brand: | HY |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument |
Label: | process multimeters , AC/DC multimeters , bench multimeter |
Price: |
¥1423.8
/ pc
|
Min. Order: | 1 pc |
H302 AC/DC process multimeters
LCD display, Data hold,Diode,Continuity,Insulation test,
auto power off,max value measuring&hold, overload protection
DC/AC Voltage&Resistance& Current&Frequency& Temperature&Capacity measuring,
Details
Ambient temperature and humidity: 0 ~40 °C (32 ~ 104 °F) < 80% RH (without condensation)
Range of temperature and humidity for guaranteed precision:
Earthing resistance measurements: 0~28 °C (32~82 °F) < 80% RH (without condensation)
Voltage measurements: 23±5 °C (73±9°F) < 80% RH (without condensation)
30V overload protection for two output terminals.
Auto range.
Overload protection within full range.
The max allowable voltage between the measuring terminal and the earth: 1000V DC or AC (virtual value)
Operation elevation: max 2000m
Display: LCD, which can show output and measured data simultaneously.
Max displayed value: 3999 number.
Polarity indication: auto indicating, ‘-’ refers to the negative polarity.
Outrange indication: ‘OL’ or ’-OL.’
Sampling frequency: about 0.4sec/time.
Unit display: display function and electric quantity unit.
Time for auto power off: 15 minutes.
Self-recovery fuse specification: 500mA/250V.
Operating source: 1.2V×4 AA battery pack with capacity2000mAH.
Batteryundervoltage indication: LCD shows symbol .
Temperature coefficient: lower than 0.1× accuracy/℃
Operating temperature: -10℃ ~40℃
Storage temperature: -20℃ ~50℃
Size: 195×92×55mm
Weight: about 600g (including the battery)
Response: Average, calibrated in rms of sine wave
DC voltage
Range |
Resolution |
Accuracy |
400mV |
0.1mV |
± (0.1% reading + 3 figures) |
4V |
1mV |
|
40V |
10mV |
|
400V |
100mV |
|
1000V |
1V |
- Input impedance: 10MΩ
- Overload protection: 400mV range: 250V DC or AC (virtual value), 4V-1000V range: 1000V DC or 750V AC (virtual value)
- Max input voltage: 1000V DC
AC voltage
Range |
Resolution |
Accuracy |
4V |
1mV |
±(0.8% reading + 3 figures) |
40V |
10mV |
|
400V |
100mV |
|
700V |
1V |
±(1.0% reading + 10 figures) |
- Input impedance: 10MΩ
- Overload protection: 1000V DC or 700V AC (virtual value)
- Max input voltage: 700V AC (virtual value)
- Frequency range: 40 ~ 400Hz
- Display: mean value (virtual value of sine wave)
DC current
Range |
Resolution |
Accuracy |
400mA |
0.1mA |
±(0.1% reading + 5 figures) |
4000mA |
1mA |
|
40mA |
10mA |
|
400mA |
100mA |
- Overload protection:
- Voltage drop
400mA range: 400mV, 4000mA range: 4V,
40mA range: 400mV, 400mA range: 4V
AC current
Range |
Resolution |
Accuracy |
400mA |
0.1mA |
±(1% reading + 5 figures) |
4000m A |
1mA |
|
40mA |
10mA |
|
400mA |
100mA |
- Overload protection:
mA, mA range: quick fusing cartridge fuse 500mA/250V
- Voltage drop
400μA range: 400mV, 4000μA range: 4V,
40mA range: 400mV, 400mA range: 4V,
- Frequency range: 40 ~400Hz
- Display: mean value (virtual value of sine wave)
400μA range: 400mV, 4000μA range: 4V,
40mA range: 400mV, 400mA range: 4V,
- Frequency range: 40 ~400Hz
- Display: mean value (virtual value of sine wave)
Resistance
Range |
Resolution |
Accuracy |
400Ω |
0.1Ω |
±(0.3% reading + 5 figures) |
4kΩ |
1Ω |
|
40kΩ |
10Ω |
|
400kΩ |
100Ω |
|
4MΩ |
1kΩ |
|
40MΩ |
10kΩ |
±(2.0% reading + 5 figures) |
- Open-circuit voltage: about 0.25V
- Overload protection: 250V DC or AC (virtual value)
Capacitance
Range |
Resolution |
Accuracy |
40nF |
10pF |
±(2.0% reading + 10 figures) |
400nF |
0.1nF |
|
4mF |
1nF |
|
40mF |
10nF |
|
|
100nF |
- Overload protection: 250V DC or AC (virtual value)
Frequency
Range |
Resolution |
Accuracy |
9.999Hz |
0.001Hz |
±10 figures
|
99.99Hz |
0.01Hz |
|
999.9Hz |
0.1Hz |
|
9.999kHz |
1Hz |
|
99.99kHz |
10Hz |
|
199.9kHz |
100Hz |
|
>200kHz |
|
Only for reference |
1) Measuring range: 0 ~5MHz
2) Input frequency amplitude: when in 0~100kHz, the amplitude is higher than 500mV。
when in 100kHz~5MHz, the amplitude is higher than 3V.
3)Input frequency amplitude shall not be higher than 10V.
4)Overload protection: 250V DC or AC (virtual value)
Accessories:
1) |
Test leads |
A pair |
2) |
Thermoelectric couple |
A pair |
3) |
Multi-purpose socket |
One |
3) |
Instruction |
One |
4) |
Test clip |
A pair |
5) |
Charger |
One |
6) |
24V output wire |
One |
7) |
Certification |
One |
Remind:
When measuring, if the measured voltage is higher than 60V DC or 30V AC (virtual value), please be noted to keep fingers behind the finger guard on the probe
Never measure the voltage higher than 1000V between the measuring terminal and the earth.
Never use this instrument near explosive gas, vapor or dust..
Warranty: One Year.
Any quality problem occurs whitin 7 days after you receive the goods,you can ask for replacement or refund as long as it is not damaged by personal mistake.
Shippment&Payment:
We usually shipped by air,such as DHL,UPS,FedEx,China post mail,EMS,TNT and etc as you like,shipping day is about 4 days or more depends on your order quantity, and the delivery day is about 20-40 days by EMS and post mail,by others it is within 20 days. We usually write gift on the packing with a low value to help you reduce the tax,however different countries have different rules, if you refuse to pay the tax at your country,the goods will be returned to us,you have to bear the loss.
As to payment, you can pay by T/T and western union as you like, we will ship the goods only after we get your full payment.
Shenzhen Huayi Technology Co. Ltd | |
---|---|
Country/Region: | Guang Dong - China |
Business Nature: | Manufacturer |
Phone: | 13872175283 |
Contact: | Alina Lee (Sales Manager) |
Last Online: | 28 Dec, 2015 |