Model: | MS830L |
---|---|
Brand: | HY |
Origin: | Made In China |
Category: | Electronics & Electricity / Electronic Instrument / Electricity Meter & Instrument |
Label: | digital multimeter , multimeter digital , professional digital |
Price: |
US $46.8
/ pc
|
Min. Order: | 1 pc |
MS830L digital AC/DC multimeters
LCD display,,LED back light,Data hold,Diode,Continuity,Insulation test,
auto power off,max value measuring&hold,
DC/AC Voltage&Resistance& Frequency& Temperature&Currency&Sound&Duty &capacity measuring,
Details
The meter is devised with light and sound alarm to prevent test leads misconnection.
Auto range and manual range options are available.
Overrange protection is provided for all ranges.
Maximum voltage between terminals and earth ground: 1000V DC or rms AC
Operating altitude: max. 2000 meters (7000 ft.)
Display: LCD, 3 readings at the same time
Maximum value display: 3999 digits
Polarity indication: automatic; ‘-‘ for negative polarity.
Overrange indication: ‘0L’ or ‘-0L’
Sampling time: approx. 0.4 second per sample
Unit indication: function and unit.
Auto power off time: 30 min.
Specification of resettable fuse: F1 500mA/250V
Fuse protection: F2 10A/250V (quick acting).
Operating power : 1.5V×3 AAA batteries
Batterylow indication: ‘ ’ on LCD
Temperature factor: < 0.1×Accuracy /℃
Operating temperature: 0℃ to 40℃(32°F to 104°F)
Storage temperature: -10℃ to 50℃(10°F to 122°F)
Dimension: 195×92×55mm
Weight: approximate 400g(including batteries)
.
DC Voltage
Range |
Resolution |
Accuracy |
400mV |
0.1mV |
±(0.7% of reading + 2 digits) |
4V |
1mV |
|
40V |
10mV |
|
400V |
100mV |
|
1000V |
1V |
- Input Impedance: 10MW
- Overload protection:
400mV range: 250V DC or rms AC,
4V-1000V ranges: 1000V DC or 750V rms AC.
AC Voltage
Range |
Resolution |
Accuracy |
400mV |
0.1mV |
|
4V |
1mV |
±(0.8% of reading + 3 digits) |
40V |
10mV |
|
400V |
100mV |
|
750V |
1V |
±(1.0% of reading + 3 digits) |
- Input Impedance: 10MW
- Overload protection:
400mV range: 250V DC or rms AC,
4V-750V ranges: 1000V DC or rms 750V AC.
- Max. input voltage: 1000V DC or rms 750V AC
- Frequency range: 40 to 400Hz
- Response: average, calibrated in rms of sine wave
DC Current
Range |
Resolution |
Accuracy |
400mA |
0.1mA |
|
4000mA |
1mA |
|
40mA |
10mA |
±(1.2% of reading + 3 digits) |
400mA |
100mA |
|
4A |
1mA |
|
10A |
10mA |
±(2.0% of reading + 10 digits) |
- Overload protection:
mA、mA ranges: resettable fuses F1 500mA/250V
10A range: F2 10A/250V fuse (quick acting).
- Max. input current:
mA jack(mA ranges): 4mA,
mA jack(mA ranges): 400mA,
10A jack: 10A
- voltage drop:
400mA ranges: 40mV,
4000mA ranges: 400mV,
40mA ranges: 40mV,
400mA ranges: 400mV,
4A range: 40mV
10A range: 100Mv
AC Current
Range |
Resolution |
Accuracy |
400mA |
0.1mA |
|
4000mA |
1mA |
|
40mA |
10mA |
±(1.5% of reading + 5 digits) |
400mA |
100mA |
|
4A |
1mA |
|
10A |
10mA |
±(3.0% of reading + 10 digits) |
- Overload protection:
mA、mA ranges: resettable fuses F1 500mA/250V
10A range: F2 10A/250V fuse (quick acting),.
- Max. input current:
mA jack(mA ranges): 4mA,
mA jack(mA ranges): 400mA,
10A jack: 10A
- voltage drop:
400mA ranges: 40mV,
4000mA ranges: 400mV,
40mA ranges: 40mV,
400mA ranges: 400mV,
4A range: 40mV
10A range: 100mV
- Frequency range: 40 to 400Hz
- Response: average, calibrated in rms of sine wave
Resistance
Range |
Resolution |
Accuracy |
400W |
0.1W |
±(1.2% of reading + 2 digits) |
4kW |
1W |
|
40kW |
10W |
|
400k( |
100W |
|
4M( |
1kW |
|
40M( |
10kW |
±(2.0% of reading + 5 digits) |
- Open circuit voltage: ~0.25V
- Overload protection: 250V DC or rms AC
Capacitance
Range |
Resolution |
Accuracy |
40nF |
10pF |
|
400nF |
0.1nF |
|
4mF |
1nF |
±(3.0% of reading + 3 digits) |
40mF |
10nF |
|
100mF |
100nF |
|
- Overload protection: 250V DC or rms AC
Frequency
Range |
Resolution |
Accuracy |
9.999Hz |
0.001Hz |
±(2.0% of reading + 5 digits) |
99.99Hz |
0.01Hz |
|
999.9Hz |
0.1Hz |
±(1.5% of reading + 5 digits) |
9.999kHz |
1Hz |
|
99.99kHz |
10Hz |
|
199.9kHz |
100Hz |
±(2.0% of reading + 5 digits) |
>200kHz |
|
for reference only |
- by Hz range:
Measurement range: 0 ~ 200kHz
Input voltage range: 0.5V – 10V rms AC (higher input voltage at higher frequency)
Overload protection: 250V DC or rms AC
- by V range:
Measurement range: 0 ~ 40kHz
Input voltage range: 0.5V – 750V rms AC (higher input voltage at higher frequency)
Input Impedance: 10MW
Max. input voltage: 1000V DC or 750V rms AC
- by mA, mA or A range:
Measurement range: 0 ~ 40kHz
Input current range: ≥ 1/4 range rms AC (higher input voltage at higher frequency)
- Max. input current:
mA jack(mA ranges): 4mA,
mA jack(mA ranges): 400mA,
10A jack: 10A
- Overload Protection:
mA、mA ranges: resettable fuses F1 500mA/250V
10A range: F2 10A/250V fuse (quick acting).
Duty
Range |
Resolution |
Accuracy |
0.1 - 99.9% |
0.1% |
±3.0% |
- By Hz range:
Frequency response: 0 ~ 200kHz
Input voltage range: 0.5V – 10V rms AC (higher input voltage at higher frequency)
Overload protection: 250V DC or rms AC (higher input voltage at higher frequency)
- By V range:
Frequency response: 0 ~ 40kHz
Input voltage range: 0.5V – 600V rms AC (higher input voltage at higher frequency)
Input Impedance: 10MW
Max. Input Voltage: 1000V DC or 750V rms AC
- By mA, mA or A range:
Frequency response: 0 ~ 40kHz
Input current range: ≥1/4 of the rms AC for the range (higher input voltage at higher frequency)
- Max. input current:
mA jack(mA ranges): 4mA,
mA jack(mA ranges): 400mA,
10A jack: 10A
- Overload protection:
mA、mA ranges: resettable fuses F1 500mA/250V
10A range: F2 10A/250V fuse (quick acting).
Relative Humidity(on RH and humidity display)
Range |
Resolution |
Accuracy |
20 - 95% |
0.1% |
±5.0%RH |
- Operating temperature: 0℃ to 40℃
- Sampling Period: ~20s.
Temperature
Temperature(on sensor, thermoresistor NTC and temperature display)
Range |
Resolution |
Accuracy |
|
℃ |
0.1℃ |
0℃ to 40℃ |
±2℃ |
℉ |
0.1℉ |
32℉ to 104℉ |
±4℉ |
- Sampling Period: ~20s.
Temperature(on sensor, thermocouple and main display)
Range |
Resolution |
Accuracy |
|
|
|
-20℃ to 0℃ |
±5.0% of reading or ±3℃ |
℃ |
1℃ |
0℃ to 400℃ |
±1.0% of reading or ±2℃ |
|
|
400℃ to 1000℃ |
±2.0% of reading |
|
|
-4℉ to 32℉ |
±5.0% of reading or ±6℉ |
℉ |
1℉ |
32℉ to 752℉ |
±1.0% of reading or ±4℉ |
|
|
752℉ to 1832℉ |
±2.0% of reading |
- Overload protection: resettable fuses F1 500mA/250V.
Sound Level(dB)
Range |
Resolution |
Accuracy |
40-100dB |
0.1 dB |
±3.5%dB at 94dB, 1kHz sine wave |
- Typical instrument frequency range: 100 ~ 8000Hz
Luminance(Lux)
Range |
Resolution |
Accuracy |
Lux (4000) |
1 Lux |
±(5.0% of reading + 10 digits) at color temp. 2856K calibrated to standard incandescent lamp |
×10Lux (40000) |
10Lux |
- Repeatability: ±2%.
Diode Test
Range |
Resolution |
Function |
|
1mV |
displaying approximate forward voltage of diode |
- Forward DC current ~1mA
- Reversed DC voltage ~1.5V
- Overload Protection: 250V DC or rms AC
Continuity Test
Range |
Function |
|
Built-in buzzer will sound if resistance is lower than 40W. |
- Open circuit voltage ~0.5V
- Overload Protection: 250V DC or rms AC
Accessories:
1) Test leads: electric rating: 1000V 10A 1 pair (set)
2) Thermocouple (K type TP01) 1 set
3) Operation Manual 1 copy
Remind:
Use the right input jack, function and range.
Do not take measurements that exceed the protection limit values indicated in the specifications
Do not touch the metal tips of the test leads when the meter is connected to the circuit to be measured.
Keep your fingers behind the probe barriers when taking a measurement with an effective voltage above 60V DC or 30V rms AC.
Do not take voltage measurement if the value between the terminals and earth ground exceeds 1000V.
Select the highest range if the value scale to be measured in the manual range is unknown.
Do not measure the resistance,capacitance, diode or continuity of live circuits.
Do not take capacitance measurements until the capacitor to be measured has been fully discharged.
Warranty: One Year.
Any quality problem occurs whitin 7 days after you receive the goods,you can ask for replacement or refund as long as it is not damaged by personal mistake.
Shippment&Payment:
We usually shipped by air,such as DHL,UPS,FedEx,China post mail,EMS,TNT and etc as you like,shipping day is about 4 days or more depends on your order quantity, and the delivery day is about 20-40 days by EMS and post mail,by others it is within 20 days. We usually write gift on the packing with a low value to help you reduce the tax,however different countries have different rules, if you refuse to pay the tax at your country,the goods will be returned to us,you have to bear the loss.
As to payment, you can pay by T/T and western union as you like, we will ship the goods only after we get your full payment.
Shenzhen Huayi Technology Co. Ltd | |
---|---|
Country/Region: | Guang Dong - China |
Business Nature: | Manufacturer |
Phone: | 13872175283 |
Contact: | Alina Lee (Sales Manager) |
Last Online: | 28 Dec, 2015 |