This kind of surge arrester should be installed at LPZ 0B-1 or higher,protecting low voltage devices from surge damage.Applied in surge arrestor Class II(Class  B)for various power supply  system.Designed according to GB 18802.1-2011/IEC61643-1:1998-02.


Technical Parameters

 Type

 TA40A/275

TA40A/320 

TA40A/385 

 TA40A/440

 Nominal operating voltage

 220V AC

220V AC 

 220V AC

 220V AC

 Maximum continuous operating voltage

 275V AC

 320V AC

 385V AC

 440V AC

 Nominal discharge current 

 20kA

20kA 

 20kA

20kA 

 Maximum discharge current    

 40kA

40kA 

 40kA

40kA 

 Protection level 

 1.6kV

1.6kV 

 1.8kV

 2.0kV

 Frequency   

 50~60Hz

50~60Hz 

 50~60Hz

50~60Hz 

Response time    

 25ns

25ns 

 25ns

25ns 

 Front fuse or air switch

 30A

30A 

 30A

30A 

 Use environment temperature

 -40°C ~ +80°C

-40°C ~ +80°C 

 -40°C ~ +80°C

-40°C ~ +80°C 

 Outer casing protection grade

 IP20

IP20 

 IP20

IP20 

 Testing standard

 GB 18802.1-2011

GB 18802.1-2011 

 GB 18802.1-2011

GB 18802.1-2011 

 Installation mode

 35mmDIN

35mmDIN 

 35mmDIN

35mmDIN 

Product About

This kind of surge arrester is designed to protect low voltage devices from surge damages, mainly used in power supply systemsuch as power distribution-room, distribution-cabinet and other important power supply system. Surge arrestor is widely used to protect mobile communication station,telecommunication center, airport, finance, and so on.

 

Technical Parameters

 Type

 TA60A/275

 TA60A/320

TA60A/385 

TA60A/440 

 Nominal operating voltage

 220V AC

 220V AC

 220V AC

 220V AC

 Maximum continuous operating voltage

 275V AC

 320V AC

 385V AC

 440V AC

 Nominal discharge current   

 30kA

 30kA

 30kA

 30kA

 Maximum discharge current 

 60kA

 60kA

 60kA

 60kA

 Protection level   

 1.8kV

 1.8kV

 2.0kV

 2.2kV

 Frequency     

 50~60Hz

 50~60Hz

 50~60Hz

 50~60Hz

 Response time 

 25ns

 25ns

 25ns

 25ns

 Front fuse or air switch

 60A

 60A

 60A

 60A

 Use environment temperature

 -40°C ~ +80°C

 -40°C ~ +80°C

 -40°C ~ +80°C 

 -40°C ~ +80°C

 Outer casing protection grade

 IP20

 IP20

 IP20

 IP20

 Testing standard

 GB 18802.1-2011

 GB 18802.1-2011

 GB 18802.1-2011

 GB 18802.1-2011

 Installation mode

 35mmDIN

 35mmDIN

 35mmDIN

 35mmDIN 

 

Product About

Surge arrestor is designed to protect low voltage devices from surge damages, mainly used in power supply system such as  power distribution-room, distribution-cabinet and other important power supply system. This kind of surge arrester widely used to protect mobile communication station, telecommunication center, airport, finance, and so on.

 

Technical Parameters

Type

TA80B/275

TA80B/320

TA80B/385

TA80B/440

 Nominal operating voltage              

 220V AC

 220V AC

 220V AC

 220V AC

 Maximum continuous operating voltage  

 275V AC

320V AC 

 385V AC

440V AC 

 Nominal discharge current              

 40kA

 40kA

40kA 

 40kA

 Maximum discharge current           

 80kA

  80kA

  80kA

 80kA 

 Protection level                                         

 2.2kV

2.4kV 

 2.6kV

2.8kV 

 Frequency                                                     

 50~60Hz

 50~60Hz

 50~60Hz

 50~60Hz

 Response time                                            

 25ns

 25ns

 25ns

 25ns

 Front fuse or air switch

 100A

100A 

 100A

100A 

 Use environment temperature

 -40°C ~ +80°C

-40°C ~ +80°C 

 -40°C ~ +80°C

-40°C ~ +80°C 

 Outer casing protection grade

 lP20

lP20 

 lP20

lP20 

 Testing standard

 GB 18802.1-2011

GB 18802.1-2011 

 GB 18802.1-2011

GB 18802.1-2011 

 Installation mode

 35mmDIN

35mmDIN 

 35mmDIN

35mmDIN 

Product About

This kind of surge arrester is installed at LPZ 0A-1 or higher, protecting low voltage equipment against lightning and surge damage. Applied in surge arrestor Class I(Class B)for various power supply system. Designed according to GB 18802.1-2011/IEC61643-1:1998-02.

 

Technical Parameters

 Type

 TA100B/275

 TA100B/320

 TA100B/385

 TA100B/440

 Nominal operating voltage

 220V AC

 220V AC

 220V AC

 220V AC

 Maximum continuous operating voltage

 275V AC

 320V AC

 385V AC

 440V AC

 Nominal discharge current

 60 A k

 60kA

  60kA

  60kA

 Maximum discharge current

 100kA

 100kA

100kA 

100kA 

 Protection level    

 2.5kV

 2.7kV

 2.9kV

 3.2kV

 Frequency   

 50~60Hz

  50~60Hz

  50~60Hz

 50~60Hz 

 Response time

 25ns

  25ns

 25ns 

  25ns

 Front fuse or air switch

 100A

  100A

 100A 

  100A

 Use environment temperature

 -40°C ~ +80°C

  -40°C ~ +80°C

 -40°C ~ +80°C 

  -40°C ~ +80°C

 Outer casing protection grade

 IP20

  IP20

 IP20 

  IP20

 Testing standard

 GB 18802.1-2011

  GB 18802.1-2011

 GB 18802.1-2011 

  GB 18802.1-2011

 Installation mode

 35mmDIN

 35mmDIN

35mmDIN 

 35mmDIN

 

 

Payment Terms:T/T, L/C, Paypal, West Union
Class II AC Power Supply SPD  1Class II AC Power Supply SPD  2Class II AC Power Supply SPD  3Class II AC Power Supply SPD  4

Member Information

Shenzhen Ruilongyuan Electronic Co.,Ltd
Country/Region:Guang Dong - China
Business Nature:Manufacturer
Phone:83508774
Contact:Taylor (Sales)
Last Online:27 Jan, 2015