Model: | TA Series |
---|---|
Brand: | RUILON |
Origin: | Made In China |
Category: | Security & Protection / Other Security & Protection |
Label: | surge arrester , surge protector , spd |
Price: |
US $1
/ pc
|
Min. Order: | 10 pc |
Product About
This kind of surge arrester should be installed at LPZ 0B-1 or higher,protecting low voltage devices from surge damage.Applied in surge arrestor Class II(Class B)for various power supply system.Designed according to GB 18802.1-2011/IEC61643-1:1998-02.
Technical Parameters
Type |
TA40A/275 |
TA40A/320 |
TA40A/385 |
TA40A/440 |
Nominal operating voltage |
220V AC |
220V AC |
220V AC |
220V AC |
Maximum continuous operating voltage |
275V AC |
320V AC |
385V AC |
440V AC |
Nominal discharge current |
20kA |
20kA |
20kA |
20kA |
Maximum discharge current |
40kA |
40kA |
40kA |
40kA |
Protection level |
1.6kV |
1.6kV |
1.8kV |
2.0kV |
Frequency |
50~60Hz |
50~60Hz |
50~60Hz |
50~60Hz |
Response time |
25ns |
25ns |
25ns |
25ns |
Front fuse or air switch |
30A |
30A |
30A |
30A |
Use environment temperature |
-40°C ~ +80°C |
-40°C ~ +80°C |
-40°C ~ +80°C |
-40°C ~ +80°C |
Outer casing protection grade |
IP20 |
IP20 |
IP20 |
IP20 |
Testing standard |
GB 18802.1-2011 |
GB 18802.1-2011 |
GB 18802.1-2011 |
GB 18802.1-2011 |
Installation mode |
35mmDIN |
35mmDIN |
35mmDIN |
35mmDIN |
Product About
This kind of surge arrester is designed to protect low voltage devices from surge damages, mainly used in power supply systemsuch as power distribution-room, distribution-cabinet and other important power supply system. Surge arrestor is widely used to protect mobile communication station,telecommunication center, airport, finance, and so on.
Technical Parameters
Type |
TA60A/275 |
TA60A/320 |
TA60A/385 |
TA60A/440 |
Nominal operating voltage |
220V AC |
220V AC |
220V AC |
220V AC |
Maximum continuous operating voltage |
275V AC |
320V AC |
385V AC |
440V AC |
Nominal discharge current |
30kA |
30kA |
30kA |
30kA |
Maximum discharge current |
60kA |
60kA |
60kA |
60kA |
Protection level |
1.8kV |
1.8kV |
2.0kV |
2.2kV |
Frequency |
50~60Hz |
50~60Hz |
50~60Hz |
50~60Hz |
Response time |
25ns |
25ns |
25ns |
25ns |
Front fuse or air switch |
60A |
60A |
60A |
60A |
Use environment temperature |
-40°C ~ +80°C |
-40°C ~ +80°C |
-40°C ~ +80°C |
-40°C ~ +80°C |
Outer casing protection grade |
IP20 |
IP20 |
IP20 |
IP20 |
Testing standard |
GB 18802.1-2011 |
GB 18802.1-2011 |
GB 18802.1-2011 |
GB 18802.1-2011 |
Installation mode |
35mmDIN |
35mmDIN |
35mmDIN |
35mmDIN |
Product About
Surge arrestor is designed to protect low voltage devices from surge damages, mainly used in power supply system such as power distribution-room, distribution-cabinet and other important power supply system. This kind of surge arrester widely used to protect mobile communication station, telecommunication center, airport, finance, and so on.
Technical Parameters
Type |
TA80B/275 |
TA80B/320 |
TA80B/385 |
TA80B/440 |
Nominal operating voltage |
220V AC |
220V AC |
220V AC |
220V AC |
Maximum continuous operating voltage |
275V AC |
320V AC |
385V AC |
440V AC |
Nominal discharge current |
40kA |
40kA |
40kA |
40kA |
Maximum discharge current |
80kA |
80kA |
80kA |
80kA |
Protection level |
2.2kV |
2.4kV |
2.6kV |
2.8kV |
Frequency |
50~60Hz |
50~60Hz |
50~60Hz |
50~60Hz |
Response time |
25ns |
25ns |
25ns |
25ns |
Front fuse or air switch |
100A |
100A |
100A |
100A |
Use environment temperature |
-40°C ~ +80°C |
-40°C ~ +80°C |
-40°C ~ +80°C |
-40°C ~ +80°C |
Outer casing protection grade |
lP20 |
lP20 |
lP20 |
lP20 |
Testing standard |
GB 18802.1-2011 |
GB 18802.1-2011 |
GB 18802.1-2011 |
GB 18802.1-2011 |
Installation mode |
35mmDIN |
35mmDIN |
35mmDIN |
35mmDIN |
Product About
This kind of surge arrester is installed at LPZ 0A-1 or higher, protecting low voltage equipment against lightning and surge damage. Applied in surge arrestor Class I(Class B)for various power supply system. Designed according to GB 18802.1-2011/IEC61643-1:1998-02.
Technical Parameters
Type |
TA100B/275 |
TA100B/320 |
TA100B/385 |
TA100B/440 |
Nominal operating voltage |
220V AC |
220V AC |
220V AC |
220V AC |
Maximum continuous operating voltage |
275V AC |
320V AC |
385V AC |
440V AC |
Nominal discharge current |
60 A k |
60kA |
60kA |
60kA |
Maximum discharge current |
100kA |
100kA |
100kA |
100kA |
Protection level |
2.5kV |
2.7kV |
2.9kV |
3.2kV |
Frequency |
50~60Hz |
50~60Hz |
50~60Hz |
50~60Hz |
Response time |
25ns |
25ns |
25ns |
25ns |
Front fuse or air switch |
100A |
100A |
100A |
100A |
Use environment temperature |
-40°C ~ +80°C |
-40°C ~ +80°C |
-40°C ~ +80°C |
-40°C ~ +80°C |
Outer casing protection grade |
IP20 |
IP20 |
IP20 |
IP20 |
Testing standard |
GB 18802.1-2011 |
GB 18802.1-2011 |
GB 18802.1-2011 |
GB 18802.1-2011 |
Installation mode |
35mmDIN |
35mmDIN |
35mmDIN |
35mmDIN |