Power cables-XLPE Insulated power Cable for Rated Voltage 0.6/1kV

Power cables-XLPE Insulated power Cable for Rated Voltage 0.6/1kV
Model:-
Brand:BAOSHIDA
Origin:Made In China
Category:Electronics & Electricity / Optical Fiber, Cable & Wire / Electric Wire & Cable
Label:BAOSHIDA , power cable , manufacturer
Price: US $60 / meter
Min. Order:1 meter
Inquire Now

Product Description

 

Product NameXLPE Insulated power Cable for Rated Voltage 0.6/1kV
Standard :
The product is manufactured according to the standard GB/T12706.1-2002, equivalent to IEC60502.
Application:
This product is suitable for rated AC voltage (U0/U) 0.6/1kV system transmitting and distributing circuit.
Product characteristics:
It is far better than all property targets of PVC insulated power cable and has overcome the short comings of physical and chemical cross-linkage, and completely reaches or surpassed GB and IEC technical property value.
The allowable max. cable conductor work temperature is 90℃; urgent excess work temperature is 130℃ during cutting-out (5S), max. conductor temperature is 250℃.
The environmental temperature for laying cable should be not less than 0℃. If laying under 0℃, the cable should be preheated.
The cable bending radius for single core should be not less than 12 times of overall cable diameter; for multi-core cable, not less than 10 times of overall cable diameter.
The current-carrying capacity is large and not limited by drop during laying.

Type and Description


Type

Description

Application

YJV

Copper conductor XLPE insulated and PVC sheathed Power cable

 

For laying indoors in tunnels or cable trench, unable to bear external mechanical forces

YJLV

Aluminium conductor XLPE insulated and PVC sheathed Power cable

YJY

Copper conductor XLPE insulated and PE sheathed Power cable

YJLY

Aluminium conductor XLPE insulated and PE sheathed Power cable

YJV22

Copper conductor XLPE insulated steel tape armoured and PVC sheathed Power cable

Indoors, tunnels, cable canal, vertically burying and easy to corrode places, can bear mechanical pressure.

YJLV22

Aluminium conductor XLPE insulated steel tape armoured and PVC sheathed Power cable

YJV23

Copper conductor XLPE insulated steel tape armoured and PE sheathed Power cable

YJLV23

Aluminium conductor XLPE insulated steel tape armoured and PE sheathed Power cable

YJV32

Copper conductor XLPE insulated fine steel wire armoured and PVC sheathed Power cable

 

Vertically laying,, can bear mechanical pulling force, but not pressure.

YJLV32

Aluminium conductor XLPE insulated fine steel wire armoured and PVC sheathed Power cable

YJV33

Copper conductor XLPE insulated fine steel wire armoured and PE sheathed Power cable

YJLV33

Aluminium conductor XLPE insulated fine steel wire armoured and PE sheathed Power cable

Production Range of Cable


Type

No. of cores

  Nom. cross-sectional area
mm²

 Copper conductor

 Aluminum conductor

YJV   YJY

YJV22   YJV23


YJLV   YJLY
YJLV22   YJLV23

 

1

1.5~800
2.5~800
10~800

YJV   YJY

YJV22   YJV23
YJV32   YJV33


YJLV   YJLY
YJLV22   YJLV23
YJLV32   YJLV33

2

1.5~400
2.5~400
2.5~400
10~400

YJV   YJY

YJV22   YJV23
YJV32   YJV33


YJLV   YJLY
YJLV22   YJLV23
YJLV32   YJLV33

3

1.5~400
2.5~400
2.5~400
10~400

YJV   YJY

YJV22   YJV23
YJV32   YJV33


YJLV   YJLY
YJLV22   YJLV23
YJLV32   YJLV33

4

1.5~400
2.5~400
2.5~400
10~400

YJV   YJY

YJV22   YJV23

YJV32   YJV33


YJLV   YJLY

YJLV22   YJLV23
YJLV32   YJLV33

 

3+1

1.5~400
4~400
1.5~400
4~400
10~400

YJV   YJY

YJV22   YJV23

YJV32   YJV33


YJLV   YJLY

YJLV22   YJLV23
YJLV32   YJLV33

 

5

1.5~400
2.5~400
1.5~400
2.5~400
10~400

YJV   YJY

YJV22   YJV23

YJV32   YJV33


YJLV   YJLY

YJLV22   YJLV23
YJLV32   YJLV33

 

4+1

1.5~400
4~400
1.5~400
4~400
10~400

YJV   YJY

YJV22   YJV23

YJV32   YJV33


YJLV   YJLY

YJLV22   YJLV23
YJLV32   YJLV33

 

3+2

1.5~400
4~400
1.5~400
4~400
10~400

 Note: The armoured single-core cables are used for D.C. system only. As for A.C. system,  non-magnetic armour material should be used, or magnetic isolation should be applied.

 

Main Technical Data of Cable


Nom. cross-sectional area of conductor
mm²

  Max. D.C. resistance of conductor at 20℃
Ω/km

   Copper

   Aluminum

1

18.1

1.5

12.1

2.5

7.41

12.1

4

4.61

7.41

6

3.08

4.61

10

1.83

3.08

16

1.15

1.91

25

0.727

1.20

35

0.524

0.868

50

0.387

0.641

70

0.268

0.443

95

0.193

0.320

120

0.153

0.253

150

0.124

0.206

185

0.0991

0.164

240

0.0754

0.125

300

0.0601

0.100

400

0.0470

0.0778

500

0.0366

0.0605

630

0.0283

0.0469

800

0.0221

0.0367

Power frequency A.C. voltage test
kV/5min

 

   3.5kV/5min
Test voltage  3.5kV/5min

Current Carrying Capacity of Cable

 

Conductor

Nom.cross-
sectional 
area of conductor
mm²

   In the air

Under the ground

 Single -core

 

2-core

 

Multi-
core

Single -core

 

2-core

 

Multi-
core


○  ○

○○○


○  ○

○○○

 

 

 

 

 

Copper
Conductor

1.5

22

30

23

21

40

43

39

25

2.5

30

40

30

28

50

57

51

33

4

39

53

40

37

71

74

67

44

6

50

67

50

46

91

94

85

54

10

70

93

70

63

123

127

114

73

16

94

124

93

84

158

165

149

94

25

124

168

126

109

201

231

192

120

35

154

207

155

132

244

258

230

144

50

191

252

189

159

292

304

274

169

70

241

306

231

195

355

372

335

205

95

297

384

288

237

433

449

404

245

120

346

439

329

273

496

512

461

278

150

399

507

380

310

554

575

518

309

185

455

591

443

355

624

650

585

347

240

552

694

521

416

725

757

681

399

300

652

810

608

473

819

855

770

446

400

777

937

934

976

500

870

1078

1061

1110

630

990

1250

 

 

 

Aluminum
Conductor

10

53

71

53

48

95

97

87

56

16

77

102

68

65

121

142

128

72

25

99

130

98

85

159

165

149

93

35

118

160

120

102

191

199

179

111

50

150

195

146

123

224

235

212

131

70

185

239

179

152

283

289

260

159

95

231

298

224

184

338

348

313

190

120

268

340

255

213

387

398

358

216

150

308

392

294

241

430

445

401

240

185

365

459

344

277

490

505

455

271

240

427

539

404

326

568

589

530

312

300

502

629

472

372

639

664

598

351

400

590

731

548

701

762

500

687

845

634

898

870

630

800

1000

Note: The screen-copper-tape and steel wire (including all copper wire for magnetism separation) of single-core steel wire armored power cable for AC system must be connected to earth well and effectively. 
The current carrying capacity is calculated by formulas of IEC, it is advised in the new edition of GB/T12706 that the current carrying capacity of steel wire armored power cable with special structure is lower than that in IEC standard, so the cross-section should be enlarged appropriately.

Installation and Operation Condition of Cable 
In the air
The distance between cable centers of single-core cables laid in parallel: cross sectional area of conductor ≤ 185mm²:2 times of the cable diameter; cross-sectional area of conductor ≥240 mm²:90mm.
Circumstance air temperature: 30℃.
Max. continuous operating temperature of conductor: 90℃.

Current carrying rating factors for different circumstance air temperature


Circumstance air temperature

20℃

25℃

30℃

35℃

40℃

45℃

Rating factor

1.09

1.04

1.00

0.95

0.90

0.84

Direct in the ground 
The single-core cables are installed separately, the distance between the cable center is 2 times of the cable diameter.
Soil temperature: 25℃.
Max. continuous operating temperature of conductor: 90℃.
Thermal resistivity of soil: 1.0℃.m/W.
Depth of Direct-Buried: 0.7m.

Current carrying rating factors for different soil temperature


Soil temperature

20℃

25℃

30℃

35℃

40℃

Rating factor

1.04

1.0

0.96

0.92

0.87

Power cables-XLPE Insulated power Cable for Rated Voltage 0.6/1kV 1Power cables-XLPE Insulated power Cable for Rated Voltage 0.6/1kV 2Power cables-XLPE Insulated power Cable for Rated Voltage 0.6/1kV 3Power cables-XLPE Insulated power Cable for Rated Voltage 0.6/1kV 4

Member Information

ShanDong BaoShiDa Cable Co.,Ltd
Country/Region:Shan Dong - China
Business Nature:Manufacturer
Phone:88681868
Contact:Marina (export trader)
Last Online:05 Jan, 2017