Model: | - |
---|---|
Brand: | BAOSHIDA |
Origin: | Made In China |
Category: | Electronics & Electricity / Optical Fiber, Cable & Wire / Electric Wire & Cable |
Label: | Nuclear power cable , BAOSHIDA , manufacture |
Price: |
US $80
/ meter
|
Min. Order: | 1 meter |
Product Name: Cable for Nuclear Power Station
Product standard:
Enterprise standard (This product is manufactured as per the standard of RCC-E)。
Application:
This product is used as 1E-class circuit for the power configuration, control, testing, communications and instrument compensation of nuclear island factory building of nuclear power plant.
Product characteristics:
1、Rated voltage(U0/U):0.6/1KV.
2、Max. permissible continuous operating temperature of conductor is 90℃, while for short circuit (no more than four seconds) the temperature is 250℃.
3、The ambient temperature under installation is -10℃~40℃.
4、The permissible bending radius under installation:
For Unshielded Cable: no less than 6 times of overall diameter
For shielded cable: no less than 8 times of overall diameter
5、Min. permissible ambient temperature under installation: -40℃
6、Normal useful life: 50 years.
7、Special properties of cable:
(1)The cable can undergo bundled burning test specified in GB/T18380.3 (IEC 332-3).
(2)The insulated conductor of cable can undergo vertical burning test specified in GB/T18380.1 (IEC332-1).
(3)The low smoke property of cable conforms to the regulations specified in GB/T 17651(IEC61034): light transmittance ≥60.
(4)The low halogen property of cable conforms to regulations specified in GB/T 17650.2(IEC60754-2): PH≥4.3,electrical conductivity<10μs/mm.
8、Electric property of cable:
(1)Cable can withstand the test of AC 3500V/5min without breakdown;
(2)The resistivity of conductorρ20 not more than 0.0172410Ω·mm²/m
(3)Insulation resistance constant: K20 not less than 3670MΩ·km、K60 not less than 367 MΩ·km、K90 not less than 36 MΩ·km.
Name, type and specifications:
Type |
Name |
|
Copper core |
Aluminum core |
|
WDZA-YJWJ-K3 |
WDZA-YJLWJ-K3 |
Class A, Category K3 XPLE insulated PO sheathed LSOH flame-retardant power cable for Nuclear Power Station |
WDZA-YJS-K3 |
WDZA-YJLS-K3 |
Class A, Category K3 XPLE insulated PO sheathed LSOH flame-retardant power cable for Nuclear Power Station |
|
|
No. of Core |
Nom.area Cross-Section area |
WDZA-YJWJ-K3 |
6/10KV |
1 |
120~630 |
WDZA-YJLWJ-K3 |
3 |
35~95 |
|
WDZA-YJS-K3 |
|||
WSZA-YJLS-K3 |
|||
Note: The cable listed above is fire retardant of A class. For class B or C, change A accordingly. |
Type |
Name |
WDZA-YJWH-K3 |
Class A, Category K3 Copper conductor XPLE insulated PO sheathed LSOH power cable for Nuclear Power Station |
WDZA-YJLS-K3 |
Class A, Category K3 Aluminum conductor XPLE insulated PO sheathed LSOH power cable for Nuclear Power Station |
WDZA-WJWJ-K3 |
Class A, Category K3 Copper conductor XPLE insulated PO sheathed LSOH flame-retardant power cable for Nuclear Power Station |
Type |
Rated Voltage |
No. of Core |
Nom.area Cross-Section area |
WDZA-YJWJ-K3 WSZA-YJWJ-K3 |
0.6/1kV |
1 |
50~400 |
WDZA-WJWJ-K3 WDZA-WJLWJ-K3 |
2 |
2.5~70 |
|
WDZA-EWJ-K3 WDZA-ELWJ-K3 |
3 |
2.5~150 |
|
WDZA-ES-K3 WDZA-ELS-K3 |
4 |
2.5~150 |
|
WDZA-WJS-K3 WDZA-WJLS-K3 |
3+1 |
3*35+1*16~3*150+1*70 |
|
WDZA-YJS-K3 WDZA-YJLS-K3 |
6 |
2*16+4*10~2*10+4*6 |
|
WDZA-SS-K3 WDZA-SLS-K3 |
|||
Note: The cable listed above is fire retardant of A class. For class B or C, change A accordingly. |
3、Control cable of 1000V used for nuclear power station
Type |
Designation |
WDZA-KYJWJP-K3 |
Class A, Category K3 XPLE insulated braided shielded PO sheathed LSOH flame-retardant control cable for Nuclear Power Station |
WDZA-KYJSP-K3 |
Class A, Category K3 XPLE insulated braided shielded PO sheathed LSOH control cable for Nuclear Power Station |
Type |
Rated Voltage |
No. of Core |
Nom.area Cross-Section area |
WDZA-KYJWJ(P)-K3 WDZA-KYJWJP2-K3
|
0.6/1kV |
2-61 |
0.5 |
2-61 |
0.75 |
||
2-61 |
1.0 |
||
2-61 |
1.5 |
||
2-48 |
2.5 |
||
2-24 |
4 |
||
2-24 |
6 |
||
2-19 |
10 |
||
Note: The cable listed above is fire retardant of A class. For class B or C, change A accordingly. |
Main Technical Properties:
No. |
Item |
Unit |
Norm |
Test method |
1 |
DC resistance of conductor |
|
Accord with GB3956 |
GB/T3048.4 |
2 |
Insulation resistance constant is at K120℃
|
MΩ/km |
3670 3.67 |
GB/T3048.5 |
3 |
Power frequency voltage test for power cable and control cable for 5 minutes |
kV |
3.5 |
GB/T3048.8 |
4 |
Continues heat cycle test
|
h
|
5000
|
HN33-5-28 |
5 |
Fire-retardant property |
|
|
|
5.1 |
Vertical burning test for insulated conductor
|
% |
Burning for 15s,stop fire 15s,repeated 5 times <2.5 |
IPCEAS-19-81 |
5.2 |
Bundled burning test
|
m |
≤2.5 |
GB/T18380.3
|
5.3 |
Test of smoke concentration
|
% |
≥60 |
GB/T17651.2
|
5.4 |
Corrosivity of burning gas for covered material
|
μS/mm |
≥4.3
|
IEC60754 GB/T60754 |
6 |
Nuclear environment test (for K1,K2 kind of cable only) |
|
|
|
6.1 |
Thermal ageing test
|
℃
|
135±3
|
GB/T2951.1 |
6.2 |
Humid heat test
|
%
|
95
|
NFC20-504 |
6.3 |
Radiation ageing time
|
℃
|
70±3
|
IEC60544 |
6.4 |
Earthquake test
|
℃ |
20
|
NFC32-021 |
6.5 |
Radiation test under LOCA accident (for K kind of cable only)
|
℃
|
70±3
|
IEC60544-2 |
6.6 |
LOCA test (for K kind of cable only) |
|
pass |
RCC-E |
ShanDong BaoShiDa Cable Co.,Ltd | |
---|---|
Country/Region: | Shan Dong - China |
Business Nature: | Manufacturer |
Phone: | 88681868 |
Contact: | Marina (export trader) |
Last Online: | 05 Jan, 2017 |