Three Phase Isolation Transformer

Three Phase Isolation Transformer
Model:-
Brand:Wapower
Origin:Made In China
Category:Electronics & Electricity / Power Transmission Equipment & Transformer
Label:three phase , isolation transforme , transformer
Price: ¥600 / pc
Min. Order:1 pc

Product Description

Product introduction

Three phase isolation transformer is mainly used in low voltage distribution system, isolating load from power supply. Distribution system is divided into TN, TT and IT. The first T indicates that the neutral point of power transformer is directly grounded. I indicates the neutral point of power transformer is non-grounded(or grounded through high impedance). The second T indicates that the case of electrical equipment is directly grounded, but have no connection with the power grid of ground system. And N indicates that the case of electrical equipment is connected with the grounded neutral wire of system.

 

TN system: the neutral point of power transformer is grounded and the case of equipment is partially connected with neutral wire.

TT system: the neutral point of power transformer is grounded and the case of equipment adopts protection grounding.

IT system: the neutral point of power transformer is non-grounded but the case of equipment adopts protection grounding.

 

In the IT system, isolation transformer can prevent electric shock, protect the connected equipment from insulation damage and make the neutral point isolated.

 


Technical parameters:

1, Power range ≤1600KVA 
2, Dielectric strength: winding-winding, winding-earth 3000VAC / 50Hz / 60s no arcing or breakdown
3, Insulation resistance: cross-core screw rob - earth 500VDC, insulation resistance value ≥100MΩ 
4, Noise level < 65 db (The testing point's horizontal distance from transformer should be 1 metre.)
5, Protection grade: IP00
6, Insulation class: H
7, Product standards:  IEC726-11 Dry-type power transformer

                                    GB1094.11-2007 Dry-type power transformer

                    IEEE.C57.12.01-2005 General requirements for dry-type power distribution and power transformer 

 


Application environment and conditions:
1, The altitude is not more than 1000 meters and if more than 1000 meters, derating is required.
2, Running temperature: -5℃-40℃, relative humidity is less than 90%. 
3, Without harmful gas, inflammable, explosive and conductive dust around.