Intelligent temperature measurement X5
The next one.
Product details
Intelligent temperature measurement
Strong, exquisite hardware, with 2 years warranty.
The newly designed hardware is specially developed for heavy daily use. Additional circuit protection, especially for electrostatic and leakage protection.
KIC has also promised to provide a two-year warranty for the hardware of this new temperature measurement product.
X is equipped with a standard K thermocouple with 7 channels, 9 channels and 12 channels. More data sampling is just the beginning. In the industry in the leading position of X ⁵ ™ can obtain more accurate data to identify the factory of each temperature curve and its process. The temperature curve data can be easily transferred to a computer via USB connection. RF version of X ⁵ ™ through wireless RF transmitters can real-time transmission curve more data to the PC. The standard AAA battery is powered by X, and you can also use a rechargeable battery to power it. It can also be powered by USB, so that the battery can extend its service life.
Intelligent data processing software.
The software of X is adopted the modern, humanized graphical interface, and quickly and intuitively guide you to complete the whole temperature curve test process. All of your critical temperature curve process data will be measured, including slope, constant temperature, reflux time, peak temperature, and so on. In addition, the software calculates the PWI value. The PWI value is used to objectively help you to identify whether the temperature curve is within the set process window range. The PWI value is less than 100, indicating that the temperature curve is within the process range. The closer your process is to the center of the process window, the lower the PWI value. As a result, the lower the PWI value indicates that your process is closer to the center of the process specification. With PWI, you can immediately see where your craft or furnace needs to be adjusted. The manual predictive power of X - to - standard will help you to see the predicted process improvement data immediately, and to change the parameters setting of the furnace. The standard software Navigator PowerTM (X) helps you automatically improve and optimize your process. In just a few seconds, Navigator Power will be able to locate the best stove preferences based on your choice of the following three criteria.
Process window center
The biggest chain speed
Minimum power loss
X - to - and standard SPC chart features help you track changes in the entire temperature curve. X is a new generation of furnace temperature tester, which further improves the customer's production quality, productivity, and process file management ability.
Accuracy: + / - 0.5 ° C
Resolution of 0.1 ° C
Internal operating temperature: 0 ° C to 85 ° C
Sampling frequency: 0.1 to 10 / SEC.
Data points: 224,640.
PC connection: USB 2.0 (std-a/mini-b)
Power demand: AAA battery or USB cable connected to the computer.
Thermocouple compatibility.
Channel: standard K thermocouple.
Temperature Range: -150 C to 1050 C.
Dimensions (length x width x height mm) :
7 channels:
202.0 x 60.0 x 17.0.
9 channels: 202.0 x 75.0 x 17.0.
12 channels: 208.0 x 98.0 x 17.0.
Heat shield: see below.
Specification of heat insulation sleeve temperature gauge.
Cable data download model: after the operation, the data is downloaded to the computer via cable cable.
Wireless data download model: the data is sent to the computer in real time during operation, and internal storage is carried out at the same time to be downloaded by USB after running.
Note: the Software of X to be configured, the Software of Profiling Software, can be directly connected with some furnace control Software, without manual input setting data. Please contact your furnace supplier to confirm its feasibility. Accuracy based on factory calibration.
Process window index
A simplified value is used to indicate the degree of conformity of the temperature curve.
PWI is a simple numerical value, it is from the mathematical Angle objective reaction to measure whether the temperature curve conforms to the process window. This method compares and ranks the different temperature curves to identify the degree of conformity of them and the process window, and thus helps the optimization of the process. The lower the PWI, the higher the process efficiency, the more stable the process! (see PWI data table for details)
Configuration size (mm)
(length x width x height) 150C 200C 250C 300C 300C 350C 400C.
Anti-ironing steel insulated sleeve,7 channels 302 x 75 x 23 17.5 12.0 9.0 7.7 6.5.
Anti-ironing stainless steel heat shield,9 channels 312 x 90 x 23 18.1 13.1. 10.8.4 6.7.
Iron and steel insulation sheath,12 channels 323 x 113 x 23 17.7 12.0.
HT Shield 400 298 x 106 x 29 24.9 17.6 14.011.5 10.1 9.2.
The full set of X products include:
thermometer
Heat insulation sleeve
The software CD
Software protects e-dogs.
USB cable
AAA batteries
scissors
Base station (receiver/transmitter)*.
The suitcase
Thermocouple *
E-file user manual.
gloves
Using the wizard
Calibration certificate
USB metal connecting line male/female connector extension cable *.
Computer configuration
Minimum system requirements
Dual core /1GHz processor PC,2G memory.
2G hard disk storage
1024 x 768 BBB 0 resolution /16 bits.
1 USB port available (for data download)
1 available USB port (for software keys)
Microsoft Windows XP, Vista or 7 (32-bit or 64-bit)
X ⁵ advantage
Economic material benefit
Fast, convenient, accurate curve measurement.
Easy to use
R ed hardware.
24-hour customer support.
X5 thermometer data sheet.
X5 thermometer A4 data sheet.
For more information on KIC products and services, please visit KIC website www.kicthermal.com or www.kic.cn.
Available services.
Technical support
Installation Settings
Application support
Hardware support
Quality assurance commitment