Safety:
1. Do not disassemble the product without permission.
2. Do not use in dangerous environment ( such as flammable and explosive )
3. Do not use in place with plenty of oil or water, high temperature and humidity.
Industry Standard and System Certificate:
1. Comply with the limit request of ANSI/ESD S20.20 on calibration test for wrist strap/human body system resistance
2. Comply with the request of ANSI/ESD S1.1 on auditing test for wrist strap/human body system resistance
3. Comply with the request of ANSI/ESD TR53 on periodic verification method for wrist strap/human body resistance
4. Comply with the limit request of IEC 61340-5-1 on periodic verification test for wrist strap/human body resistance
5. Comply with limit request of GJB3007A-2009 on periodic verification test for wrist strap/human body resistance
Feature:
1. Measure dual wrist strap system resistance in real time, which ensure the personnel grouding connection is more safety and stable.
2. Start testing while plug wrist strap into monitor, no monitoring turn off function.
3. Monitor two dual wrist straps of two station and one ESD table mat or grounding connection, it's convenient to support different options for customer's request of different stations.
4. The ESD table mat alarm value is set by monitoring the resistance range of the ESD table mat to ensure the efficiency and stability of the electrostatic discharge path between the ESD table mat and the ground wire. The resistance setting of the ground connection have multiple gears, which is convenient for customers to choose the impedance of different meter to the ground, to ensure the unobstructed release path of the equipment to the ground, and to ensure the safety of the product.
5. Accuracy: 1 ± 20% ( e.g. When set wrist strap upper limit to 10M ohms, 8M pass and 12M failed; When set ground limit to 10 ohms, 8 ohms pass and 12 ohms failed )
6. Aluminum alloy casing design: Stylish appearance and with good shielding performance.
Verification Check:
Equipment required: For this test, the workstation monitor should be disconnected from the monitored ground. Use the ESDMAN 001-1001, to prevent misreading, the ESDMAN 001-1001 incorporates a color coding systems to divide the display into 3 groups to indicate ohms, Kilohms and Megohms. Special attention has been given to reliability. A special multiple gold contact switch arrangement ensures that back-up contacts are always available to take over should a contact fail.
1. Attach two banana plugs into red and blue jacks respectively, the other end terminal is 3.5 mono channel, let it connect to monitor OP1 or OP2. Then adjust the resistance of ESDMAN 001-1001 to 8M, OP1 or OP2 should be green, it indicates monitor works correctly. Once resistance of ESDMAN 001-1001 at 12M, OP1 or OP2 should remain red.
2. Attach two banana plugs into red and black jacks respectively, another terminal connect the jack of GND of the monitor. Adjust ESDMAN 001-1001 resistance box to 8 Ω, monitor GND LED remain green, adjust to 12 Ω, monitor GND LED illuminates red ( Option 2: unpl ing the green color ground connection to check for alarm trigger ).