Model: | MLT4-B1-1-100 |
---|---|
Brand: | - |
Origin: | Made In Taiwan, China |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | SPD , SEAT , Surges |
Price: |
-
|
Min. Order: | - |
Last Online:18 Jan, 2019 |
♦ Types of surge suppressed:
Lightning Flash Surges, Power switching surges, Switching Inrush Current , and Electric Magnetic Pulse.
♦ Method of handling surge energy:
Series mode surge energy absorbed and transferred to voltage.
♦ Number of signal protection circuit:
1 circuit with two-port structure.
♦ Case of Devices:
Metal case with anode treatment and sand blasting to prevent EMI interference of itself.
♦ Suitable DC voltage:
DC 12V-100V.
♦ Suitable frequency range:
Less than 3M Hz.
♦ Max. load current allowed:
1 A.
♦ Input Impedance (R) without loads:
>10MΩ.
♦ Core module temperature of 1A load:
Less than 30 oC.
♦ Surge immunity:
1.2x50μs,2.5kV; 8x20μs,1.25kA combination wave, 30 sec interval, at least 3 times.
♦ Surge energy absorbing rate:
1.2x50μs, 2.5kV; 8x20μs, 1.25kA combination wave, 92%±2% (ungrounding condition).
♦ After surge invasion, DC waveform recovering time:
Less than10mS.
♦ EMP(fast transient/bust) immunity:
3kV, 5x50ns EFT waveform, 91%±2% (ungrounding condition).
♦ Loads remnant voltage:
250V±20% under combination wave tested.
♦ Load protection mode:
L-N.
♦ System ground resistance demand:
None.
♦ Operation temperature range and humidity range:
-40 to +85oC, 35 to 95% relative humidity (no dew).
♦ Dimension:
Base 66mm(L)/33mm(W), Cover 66mm(L)/33mm(W)/23mm(H) ±1%.
♦ Weight:
62g ±5%.
♦ Confirm standards:
ANSI C62.41、IEC 61000-4-5、IEC 61000-4-4、IEC 61643-1、ANSI C37.90.1etc.
♦ Surge-testing:
Tested by 2.5kV/1.25kA combination wave, 3kV, 5x50ns EFT wave.