Model: | 001-6506 |
---|---|
Brand: | ESDMAN |
Origin: | Made In China |
Category: | Electronics & Electricity / Other Electrical & Electronic |
Label: | 001-6506 , ESDMAN |
Price: |
US $600
/ pc
|
Min. Order: | 1 pc |
Last Online:20 Jul, 2022 |
Safety:
1. Do not disassemble the product without permission
2. Do not use in dangerous environment ( such as flammable and explosive )
3. Do not use in place with plenty of oil or water, High temperature and humidity
Industry Standard and System Certificate:
1. Comply with ISO/CD8782-I Standard
2. Comply with the limit request of ANSI/ESD S20.20 on calibration test for wrist strap/human body system resistance and footwear/human body system resistance
3. Comply with the request of ANSI/ESD S1.1 on auditing test for wrist strap/human body system resistance
4. Comply with the request of ANSI/ESD STM 9.1 on auditing test for footwear/human body system resistance
5. Comply with the request of ANSI/ESD TR53 on periodic verification method for wrist strap/human body resistance and footwear/human body resistance
6. Comply with the limit request of IEC 61340-5-1 on periodic verification test for wrist strap/human body resistance and footwear/human body resistance
7. Comply with limit request of GJB3007A-2009 on periodic verification test for wrist strap/human body resistance and footwear/human body resistance
Features:
1. Test single/dual wire wrist strap, footwear system resistance
2. Wrist strap test range: 750K-10M
3. Footwear test range: 750K-100M, could be adjusted upon request
4. Corresponded LED light of FAIL LOW/PASS/FAIL HIGH display testing result, LCD screen can show detailed value
5. Test FAIL comes with audible alarm
6. Unique touch button, avoid mechanical failure and reduce maintenance
7. Test OK provide door opening signal and could be linked with tripod gate
8. Low voltage for safety power supply
9. Beautiful design meet with ergonomics
10. Fast test and stable testing result
How to Use:
1. Wear wrist strap and ESD shoes, connect wrist strap into testing terminal, operator stand on the stainless steel footplate
2. Finger gently press"PRESS TO TEST"test button to start test, finger off stop test, LCD screen will display 2 sec test result for each test, if the pressing time is more than 5 seconds, the test will stop automatically, release and re-contact and do test again
3. Test wrist strap/ESD shoes at the same time
4. Top middle display wrist strap resistance, left indication is left footwear system resistance, cright indication is right footwear system resistance
5. Test OK comes with audible alarm and gate opening signal, operator can push in
Attention:
Gently press the test button,do not press by gravity
Humidity and temperature will directly affect the resistance of the measured item
a. When the temperature and humidity are in low condition, the resistance of the object will increase obviously and the test time will increase. Therefore, in winter, due to the dry skin of human body and the decrease of conductivity of anti-static shoes, the upper limit of resistance will be exceeded when testing
Solution
1. ESD paste can be applied to solve the problem of high resistance of human skin
2. Step on moisture mat to solve the problem of high resistance of ESD shoes
3. Extend the time interval between putting on the shoes and testing, increase the humidity in shoes to solve the problem of high resistance of ESD shoes
4. If possible, increase the ambient temperature and humidity properly
b. Under the condition of high humidity, a thin water film condenses or adsorbs on the surface of the object. This hygroscopicity enhances the conductivity of the tested object, which makes the test value sometimes exceed the lower limit of resistance
Solution
1. Use ventilation and dehumidification to reduce the humidity on the surface of the measured object
2. If possible, lower the ambient temperature and humidity properly
Abnormal Alarm:
1. Test without LED light /indication
Solution: It may be related to loose power adapter connector or transformer in short circuit, replace a new power adapter
2. Test only has High LED light,no Low light
Solution: It may be related to test button wires disconnected, need to open the meter and re weld the wires