Model |
HS-100-5 |
HS-100-12 |
HS-100-15 |
HS-100-24 |
HS-100-36 |
HS-100-48 |
output |
DC voltage |
5V |
12V |
15V |
24V |
36V |
48V |
Voltage tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% |
Rated current |
20A |
8.3A |
6.7A |
4.2A |
2.8A |
2A |
Current range |
0~20A |
0~8.3A |
0~6.7A |
0~4.2A |
0~2.8A |
0~2A |
Rated power |
100W |
99.6W |
100.5W |
100.8W |
100.8W |
96W |
Ripple&noise |
80mvp-p |
120mvp-p |
120mvp-p |
150mvp-p |
150mvp-p |
180mvp-p |
DCvoltage ADJ.range |
-9%~+10% |
±10% |
±10% |
±10% |
±10% |
±10% |
input |
Voltage range |
90~132VAC/180~264VAC(selected by switch),254~373VDC |
frequency |
47~63HZ |
AC current |
2.4A/115VAC,1.2A/230VAC |
efficiency |
79% |
83% |
83% |
85% |
85% |
86% |
Inrush current |
Cold start current18A/115VAC,36A/230VAC |
Leakage current |
< 3.5mA/240VAC |
protection |
overload |
Rated output power115%~150% start over load protection |
protection type:hiccup mode,auto-recovery after fault condition is removed |
Over voltage |
6.8~8.2V |
15.6~17.8V |
18.6~20.8V |
30.6~33.2V |
42.6~44.2V |
54.8~56.6V |
protection type:hiccup mode,auto-recovery after fault condition is removed |
----- |
----- |
----- |
environment |
Working temp,humidity |
-10°C~+60°C,20%~90%RH |
Storage temp,humidity |
-20°C~+85°C,10%~95%RH non-condensing |
Withstand vibration |
10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes |
safety |
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolated resistance |
I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC |
Fit standard |
Safety standard |
Compliance toUL1012 |
EMC standard |
Compliance toEN55022,CLASSA |
others |
Dimension |
159*97*38mm(L*W*H) |
Weight/packing |
0.48kg/45pcs/22.5kg/0.041 m³/1.45CUFT |
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25°Cof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation. |